Selling Agilent HP E6000C – We Buy New Used E6000C (‘s) Top Dollar Paid!

If you’re looking to Sell Agilent HP E6000C Mini OTDR With E6003A SM Module

The Agilent Mini-OTDR is the best selling product in Agilent’s portfolio of Optical Network Test Solutions for the installation, maintenance and operation of fiber networks.

The Mini-OTDR is designed to provide its users with the fastest tool available for installing and commissioning multiple fiber links and locating faults for fiber maintenance. This is accomplished through high measurement performance and an award winning simple user interface.

Fiber Break Locator to quickly find breaks and bends.

Locate and characterize splice and connector losses.

Multifiber testing for fast high-count cable qualification.

Perform power and loss measurement with the built-in light source and the power meter module.

Graphical representation of measurement results in event tables, showing loss and reflection, and pass/fail results.

Visual Fault Finder to check patch cords for light leakage.

Characteristics:

Horizontal Parameters

Start-km:
0 km to 400 km Span: 0.1 km to 400 km
Readout resolution: 0.1 m
Minimum sample spacing: 4 cm
Refractive index: 1.00000 to 2.00000
Length unit: km, ft, or miles
Measurement points: up to 64000

Vertical Parameters

Vertical scale
0.1 to 10.0 dB/Div Read-out resolution: 0.001 dB
Reflectance range: 14 dB to 60 dB
Backscatter coefficient: 10 to 70 dB at 1 s
Pulsewidth

You can select any of the following pulsewidths: 10 ns, 30 ns, 100 ns, 300 ns, 1 s, 3 s, and 10 s (all modules). You can also select 5 ns for E6003C, 5A, 9A modules, and 20 s for E6003B, E6003C, E6008B, and E6013A.
With the E6005A module, you can select a pulsewidth from 5 ns to 100 ns at 850 nm, and from 5 ns to 10 s at 1300 nm.
With the E6009A module, you can select a pulsewidth from 5 ns to 100 ns at 850 nm, and from 5 ns to 1 s at 1300 nm.
Storage

3.5 floppy disk drive: for high density 720/1440 kByte floppy disks. MS-DOS format compatible. Reduced operating temperature of 5C to 45C, with 35% to 80% humidity at 40C. Memory Card: PCMCIA Type II. 440 MB with up to 13000 traces (typical with 64000 data points).
Internal memory: SRAM up to 2 MB. Up to 300 traces (typical) with 4000 data points
OTDR Trace Formats:

Trace format: compliant to the following Bellcore/Telcordia OTDR trace formats:
GR 196, Revision 1.0
GR 196, Revision 1.1
SR-4731 Revision 2.0
Trace Information: 5 comment labels of up to 15 alphanumeric characters, and 5 comment fields of up to 41 alphanumeric characters are provided for each trace.
Real-time clock and date
Scan Trace:

Type of events:

Reflective and nonreflective. Maximum number of events: 100.
Threshold for non-reflective events: 0.0 to 5.0 dB, selectable in 0.01 dB steps.
Threshold for reflective events: – 14.0 to ?65.0 dB, selectable in 0.1 dB steps.
Threshold for fiber breaks: 0.1 to 10 dB, selectable in 0.1 dB steps.
Fiber End Threshold: 0.1 to 20 dB, selectable in 0.1 dB steps.
Display Color or monochrome VGA-LCD: 18.3 cm (7.2?)
Display points: 640 x 480 Points
Measurement update rate: two measurements per second in refresh mode
Interfaces:

RS232C: Maximum transmission rate: 115200 bps Transmission time at 115200 bps for trace data: 4000 points at approx. 1 second; 64000 points at approx. 4 seconds.
Centronics: Standard parallel port (SPP).
Keyboard: PS2 (Min-DIN). For English Standard, PS2, or AT keyboard.

Buying, Selling, Trading Agilent HP E6000C
General:

Automatic setup analysis
Instrument settings: storage and recall of user-selectable instrument settings.
Laser safety class: All OTDR laser sources specified by this data sheet are classified as Class 1M according to IEC 60825-1 (2001).
The Visual Fault Finder Sub-Module E6007A complies with Class 2 according to IEC 60825-1 (2001).
All laser sources comply with 21 CFR 1040.10 except for deviations pursuant to Laser Notice No. 50, dated 2001-July-26

Built-in Applications:

Automatic Multi Fiber Test
Pass/Fail Test
Fiber Break Locator
Power Meter / Loss Test mode 1
Visual Fault Finder mode 1
Optical Return Loss
End to End Loss
Easy OTDR
OTDR Training
OTDR Assistant
Environmental

Operating Temperature: 0 to 50 degees C Storage Temperature: 40 to +60 degrees C
Humidity: 95% R.H from 0 to 40 degrees C
Power

AC: 100 240 Vrms
10% 50 60 Hz DC: 16 24 V
External Battery: NiMHtypically 8 hours continuous operation (minimum 4 hours) with Option #006. Charging time < 3 hours, non-operating
Low battery indicator
Battery charge status

If you’re selling your Agilent HP E6000C please fill out form on the right hand side of page.

Selling Agilent HP E6000C – We Buy New Used E6000C (‘s) Top Dollar Paid!

If you’re looking to Sell Agilent HP E6000C SM Fiber Long Haul OTDR

The Agilent Mini-OTDR is the best selling product in Agilent’s portfolio of Optical Network Test Solutions for the installation, maintenance and operation of fiber networks.

The Mini-OTDR is designed to provide its users with the fastest tool available for installing and commissioning multiple fiber links and locating faults for fiber maintenance. This is accomplished through high measurement performance and an award winning simple user interface.

Fiber Break Locator to quickly find breaks and bends.

Locate and characterize splice and connector losses.

Multifiber testing for fast high-count cable qualification.

Perform power and loss measurement with the built-in light source and the power meter module.

Graphical representation of measurement results in event tables, showing loss and reflection, and pass/fail results.

Visual Fault Finder to check patch cords for light leakage.

Characteristics:

Horizontal Parameters

Start-km:
0 km to 400 km Span: 0.1 km to 400 km
Readout resolution: 0.1 m
Minimum sample spacing: 4 cm
Refractive index: 1.00000 to 2.00000
Length unit: km, ft, or miles
Measurement points: up to 64000

Vertical Parameters

Vertical scale
0.1 to 10.0 dB/Div Read-out resolution: 0.001 dB
Reflectance range: 14 dB to 60 dB
Backscatter coefficient: 10 to 70 dB at 1 s
Pulsewidth

You can select any of the following pulsewidths: 10 ns, 30 ns, 100 ns, 300 ns, 1 s, 3 s, and 10 s (all modules). You can also select 5 ns for E6003C, 5A, 9A modules, and 20 s for E6003B, E6003C, E6008B, and E6013A.
With the E6005A module, you can select a pulsewidth from 5 ns to 100 ns at 850 nm, and from 5 ns to 10 s at 1300 nm.
With the E6009A module, you can select a pulsewidth from 5 ns to 100 ns at 850 nm, and from 5 ns to 1 s at 1300 nm.

Storage

3.5 floppy disk drive: for high density 720/1440 kByte floppy disks. MS-DOS format compatible. Reduced operating temperature of 5C to 45C, with 35% to 80% humidity at 40C. Memory Card: PCMCIA Type II. 440 MB with up to 13000 traces (typical with 64000 data points).
Internal memory: SRAM up to 2 MB. Up to 300 traces (typical) with 4000 data points
OTDR Trace Formats:

Trace format: compliant to the following Bellcore/Telcordia OTDR trace formats:
GR 196, Revision 1.0
GR 196, Revision 1.1
SR-4731 Revision 2.0
Trace Information: 5 comment labels of up to 15 alphanumeric characters, and 5 comment fields of up to 41 alphanumeric characters are provided for each trace.
Real-time clock and date
Scan Trace:

Type of events:

Reflective and nonreflective. Maximum number of events: 100.
Threshold for non-reflective events: 0.0 to 5.0 dB, selectable in 0.01 dB steps.
Threshold for reflective events: – 14.0 to ?65.0 dB, selectable in 0.1 dB steps.
Threshold for fiber breaks: 0.1 to 10 dB, selectable in 0.1 dB steps.
Fiber End Threshold: 0.1 to 20 dB, selectable in 0.1 dB steps.
Display Color or monochrome VGA-LCD: 18.3 cm (7.2?)
Display points: 640 x 480 Points
Measurement update rate: two measurements per second in refresh mode
Interfaces:

RS232C: Maximum transmission rate: 115200 bps Transmission time at 115200 bps for trace data: 4000 points at approx. 1 second; 64000 points at approx. 4 seconds.
Centronics: Standard parallel port (SPP).
Keyboard: PS2 (Min-DIN). For English Standard, PS2, or AT keyboard.
General:

Automatic setup analysis
Instrument settings: storage and recall of user-selectable instrument settings.
Laser safety class: All OTDR laser sources specified by this data sheet are classified as Class 1M according to IEC 60825-1 (2001).
The Visual Fault Finder Sub-Module E6007A complies with Class 2 according to IEC 60825-1 (2001).
All laser sources comply with 21 CFR 1040.10 except for deviations pursuant to Laser Notice No. 50, dated 2001-July-26

Built-in Applications:

Automatic Multi Fiber Test
Pass/Fail Test
Fiber Break Locator
Power Meter / Loss Test mode 1
Visual Fault Finder mode 1
Optical Return Loss
End to End Loss
Easy OTDR
OTDR Training
OTDR Assistant

Buying, Selling, Trading Agilent HP E6000C
Environmental

Operating Temperature: 0 to 50 degees C Storage Temperature: 40 to +60 degrees C
Humidity: 95% R.H from 0 to 40 degrees C
Power

AC: 100 240 Vrms
10% 50 60 Hz DC: 16 24 V
External Battery: NiMHtypically 8 hours continuous operation (minimum 4 hours) with Option #006. Charging time < 3 hours, non-operating
Low battery indicator
Battery charge status

E6003A Specifications:

Wavelength 1310/1550nm
Dynamic Range (dB) 35/34dB
Event Deadline 3m
Attenuation Dead Zone 10/12m
Recommended Application Metropolitan/Trunk
Fiber Type Single-Mode
Module E6003A

Agilent E6006A Power Meter Submodule
Characteristics
Sensor element: InGaAs
Wavelength range: 800 ? 1650 nm
Calibrated wavelengths: 850 nm, 1300 nm,
1310 nm, 1550 nm, 1625 nm
(special wavelengths on request).
Power range: +10 to -70 dBm
Max. input power (damage level): +13
dBm/20 mW
Display Resolution: 0.01 dB
Display Units: dBm, dB, mW, µW, nW, pW
Display Contents
• Calibrated ? in nm
• Modulation frequency in Hz
• Reference value in dB
Display Updates per second: 3
Optical input: User-exchangeable
Connector Interface
Applicable fiber type: 9/125 µm, 50/125
µm, 62.5/125 µm
Specifications
Uncertainty at reference conditions:
± 3%
Power level: – 20 dBm
Continuous Wave (CW)
Wavelength: 1300±3 nm, 1310±3 nm,
1550±3 nm
Fiber type: 50/125 µm graded index,
Agilent/HMS-10 connector
Spectral bandwidth: up to 10 nm
Ambient temperature: +18 to + 28 °C
At day of calibration (add 0.3% for aging of
over one year; add 0.6% for aging of over
two years).
Total uncertainty: ± 5% ± 0.5 nW
(1310, 1550 nm)
Power level: +0 to ?50 dBm
Continuous Wave (CW)
Wavelength: 850±3 nm, 1300±3 nm,
1310±3 nm, 1550±3 nm,
Fiber type: SM to 50µm graded index
(add 2% to total uncertainty for fiber
62.5µm).
Straight and angled connectors
Ambient temperature: +10 to +40°C
Within 2 years after calibration
Supplementary Performance
Characteristics
• Automatic Zeroing Circuitry
• Automatic Ranging
• Modulation frequency
recognition (270 Hz, 1 kHz,
2 kHz) is available at power level
between +10 and ?45 dBm
(peak amplitude).
• Dual Wavelength measurement
is available at power levels
between +10 and ?45 dBm
(peak amplitude).
• Wavelength encoding recognition
(350 Hz, 550 Hz) is available at
power levels between +10 and ?45
dBm (peak amplitude).
• Reference value is presettable
from +30 to ?80 dBm
• Each calibrated wavelength has
its own reference memory.
• The actual display content can
be transferred to reference
memory(DISP?REF).
• Hold Data functionality
General Specifications
Dimensions: ca. 120 mm H x 40 mm W
x 25 mm D (4.7? x 1.6? x 1.0?)
Weight: <130g.
Operating Temperature: 0 to +50 °C
Storage Temperature: -40 to +60 °C
Humidity: 95% R.H. from 0°C to 40°C
non cond.

If you’re selling your Agilent HP E6000C please fill out form on the right hand side of page.

Selling Agilent HP E6000C E6003B E6009A – We Buy New Used E6000C E6003B E6009A (‘s) Top Dollar Paid!

If you’re looking to Sell Agilent HP E6000C E6003B E6009A SM MM Fiber OTDR

The Agilent Mini-OTDR is the best selling product in Agilent’s portfolio of Optical Network Test Solutions for the installation, maintenance and operation of fiber networks.

The Mini-OTDR is designed to provide its users with the fastest tool available for installing and commissioning multiple fiber links and locating faults for fiber maintenance. This is accomplished through high measurement performance and an award winning simple user interface.

Fiber Break Locator to quickly find breaks and bends.

Locate and characterize splice and connector losses.

Multifiber testing for fast high-count cable qualification.

Perform power and loss measurement with the built-in light source and the power meter module.

Graphical representation of measurement results in event tables, showing loss and reflection, and pass/fail results.

Visual Fault Finder to check patch cords for light leakage.

Characteristics:

Horizontal Parameters

Start-km:
0 km to 400 km Span: 0.1 km to 400 km
Readout resolution: 0.1 m
Minimum sample spacing: 4 cm
Refractive index: 1.00000 to 2.00000
Length unit: km, ft, or miles
Measurement points: up to 64000

Vertical Parameters

Vertical scale
0.1 to 10.0 dB/Div Read-out resolution: 0.001 dB
Reflectance range: 14 dB to 60 dB
Backscatter coefficient: 10 to 70 dB at 1 s
Pulsewidth

You can select any of the following pulsewidths: 10 ns, 30 ns, 100 ns, 300 ns, 1 s, 3 s, and 10 s (all modules). You can also select 5 ns for E6003C, 5A, 9A modules, and 20 s for E6003B, E6003C, E6008B, and E6013A.
With the E6005A module, you can select a pulsewidth from 5 ns to 100 ns at 850 nm, and from 5 ns to 10 s at 1300 nm.
With the E6009A module, you can select a pulsewidth from 5 ns to 100 ns at 850 nm, and from 5 ns to 1 s at 1300 nm.
Storage

3.5 floppy disk drive: for high density 720/1440 kByte floppy disks. MS-DOS format compatible. Reduced operating temperature of 5C to 45C, with 35% to 80% humidity at 40C. Memory Card: PCMCIA Type II. 440 MB with up to 13000 traces (typical with 64000 data points).
Internal memory: SRAM up to 2 MB. Up to 300 traces (typical) with 4000 data points

Buying, Selling, Trading Agilent HP E6000C E6003B E6009A
OTDR Trace Formats:

Trace format: compliant to the following Bellcore/Telcordia OTDR trace formats:
GR 196, Revision 1.0
GR 196, Revision 1.1
SR-4731 Revision 2.0
Trace Information: 5 comment labels of up to 15 alphanumeric characters, and 5 comment fields of up to 41 alphanumeric characters are provided for each trace.
Real-time clock and date
Scan Trace:

Type of events:

Reflective and nonreflective. Maximum number of events: 100.
Threshold for non-reflective events: 0.0 to 5.0 dB, selectable in 0.01 dB steps.
Threshold for reflective events: – 14.0 to ?65.0 dB, selectable in 0.1 dB steps.
Threshold for fiber breaks: 0.1 to 10 dB, selectable in 0.1 dB steps.
Fiber End Threshold: 0.1 to 20 dB, selectable in 0.1 dB steps.
Display Color or monochrome VGA-LCD: 18.3 cm (7.2?)
Display points: 640 x 480 Points
Measurement update rate: two measurements per second in refresh mode
Interfaces:

RS232C: Maximum transmission rate: 115200 bps Transmission time at 115200 bps for trace data: 4000 points at approx. 1 second; 64000 points at approx. 4 seconds.
Centronics: Standard parallel port (SPP).
Keyboard: PS2 (Min-DIN). For English Standard, PS2, or AT keyboard.
General:

Automatic setup analysis
Instrument settings: storage and recall of user-selectable instrument settings.
Laser safety class: All OTDR laser sources specified by this data sheet are classified as Class 1M according to IEC 60825-1 (2001).
The Visual Fault Finder Sub-Module E6007A complies with Class 2 according to IEC 60825-1 (2001).
All laser sources comply with 21 CFR 1040.10 except for deviations pursuant to Laser Notice No. 50, dated 2001-July-26

Built-in Applications:

Automatic Multi Fiber Test
Pass/Fail Test
Fiber Break Locator
Power Meter / Loss Test mode 1
Visual Fault Finder mode 1
Optical Return Loss
End to End Loss
Easy OTDR
OTDR Training
OTDR Assistant
Environmental

Operating Temperature: 0 to 50 degees C Storage Temperature: 40 to +60 degrees C
Humidity: 95% R.H from 0 to 40 degrees C
Power

AC: 100 240 Vrms
10% 50 60 Hz DC: 16 24 V
External Battery: NiMHtypically 8 hours continuous operation (minimum 4 hours) with Option #006. Charging time < 3 hours, non-operating
Low battery indicator
Battery charge status
E6003B Specifications:

Wavelength 1310/1550nm
Dynamic Range (dB) 40/39dB
Event Deadline 3m
Attenuation Dead Zone 10/12m
Recommended Application Metropolitan/Trunk
Fiber Type Single-Mode
Module E6003B

E6009A Specifications:
Wavelength 850/1300nm
Dynamic Range (dB)
18/23dB
Event Deadline 3m
Attenuation Dead Zone
10m
Recommended Application
LAN
Fiber Type
MultiMode
Module
E6009A

E6006A Power Meter Module Specifications:
Sensor Element
InGaAs
Wavelength Range
800 – 1650 nm
Calibrated Wavelengths
850/1300/1310/1550/1625 nm
Power Range
+10 to -70 dBm
Max. Input Power
+13 dBm / 20 mW
Display Resolution
0.01 dB
Display Units
dBm, dB, mW, µW, nW, pW
Display Contents
Calibrated in nm
Modulation frequency in Hz
Reference vaule in dB
Applicable Fiber Type
9/1250 µm, 50/125 µm, 62.5/125 µm

If you’re selling your Agilent HP E6000C E6003B E6009A please fill out form on the right hand side of page.

Selling Agilent HP E6000C – We Buy New Used E6000C (‘s) Top Dollar Paid!

If you’re looking to Sell Agilent HP E6000C Mini OTDR Mainframe

The Agilent Mini-OTDR is the best selling product in Agilent’s portfolio of Optical Network Test Solutions for the installation, maintenance and operation of fiber networks.

The Mini-OTDR is designed to provide its users with the fastest tool available for installing and commissioning multiple fiber links and locating faults for fiber maintenance. This is accomplished through high measurement performance and an award winning simple user interface.

Fiber Break Locator to quickly find breaks and bends.

Locate and characterize splice and connector losses.

Multifiber testing for fast high-count cable qualification.

Perform power and loss measurement with the built-in light source and the power meter module.

Graphical representation of measurement results in event tables, showing loss and reflection, and pass/fail results.

Visual Fault Finder to check patch cords for light leakage.

Characteristics:

Horizontal Parameters

Start-km:
0 km to 400 km Span: 0.1 km to 400 km
Readout resolution: 0.1 m
Minimum sample spacing: 4 cm
Refractive index: 1.00000 to 2.00000
Length unit: km, ft, or miles
Measurement points: up to 64000

Vertical Parameters

Vertical scale
0.1 to 10.0 dB/Div Read-out resolution: 0.001 dB
Reflectance range: 14 dB to 60 dB
Backscatter coefficient: 10 to 70 dB at 1 s
Pulsewidth

You can select any of the following pulsewidths: 10 ns, 30 ns, 100 ns, 300 ns, 1 s, 3 s, and 10 s (all modules). You can also select 5 ns for E6003C, 5A, 9A modules, and 20 s for E6003B, E6003C, E6008B, and E6013A.
With the E6005A module, you can select a pulsewidth from 5 ns to 100 ns at 850 nm, and from 5 ns to 10 s at 1300 nm.
With the E6009A module, you can select a pulsewidth from 5 ns to 100 ns at 850 nm, and from 5 ns to 1 s at 1300 nm.
Storage

3.5 floppy disk drive: for high density 720/1440 kByte floppy disks. MS-DOS format compatible. Reduced operating temperature of 5C to 45C, with 35% to 80% humidity at 40C. Memory Card: PCMCIA Type II. 440 MB with up to 13000 traces (typical with 64000 data points).
Internal memory: SRAM up to 2 MB. Up to 300 traces (typical) with 4000 data points
OTDR Trace Formats:

Trace format: compliant to the following Bellcore/Telcordia OTDR trace formats:
GR 196, Revision 1.0
GR 196, Revision 1.1
SR-4731 Revision 2.0
Trace Information: 5 comment labels of up to 15 alphanumeric characters, and 5 comment fields of up to 41 alphanumeric characters are provided for each trace.
Real-time clock and date

Buying, Selling, Trading Agilent HP E6000C
Scan Trace:

Type of events:

Reflective and nonreflective. Maximum number of events: 100.
Threshold for non-reflective events: 0.0 to 5.0 dB, selectable in 0.01 dB steps.
Threshold for reflective events: – 14.0 to ?65.0 dB, selectable in 0.1 dB steps.
Threshold for fiber breaks: 0.1 to 10 dB, selectable in 0.1 dB steps.
Fiber End Threshold: 0.1 to 20 dB, selectable in 0.1 dB steps.
Display Color or monochrome VGA-LCD: 18.3 cm (7.2?)
Display points: 640 x 480 Points
Measurement update rate: two measurements per second in refresh mode
Interfaces:

RS232C: Maximum transmission rate: 115200 bps Transmission time at 115200 bps for trace data: 4000 points at approx. 1 second; 64000 points at approx. 4 seconds.
Centronics: Standard parallel port (SPP).
Keyboard: PS2 (Min-DIN). For English Standard, PS2, or AT keyboard.
General:

Automatic setup analysis
Instrument settings: storage and recall of user-selectable instrument settings.
Laser safety class: All OTDR laser sources specified by this data sheet are classified as Class 1M according to IEC 60825-1 (2001).
The Visual Fault Finder Sub-Module E6007A complies with Class 2 according to IEC 60825-1 (2001).
All laser sources comply with 21 CFR 1040.10 except for deviations pursuant to Laser Notice No. 50, dated 2001-July-26

Built-in Applications:

Automatic Multi Fiber Test
Pass/Fail Test
Fiber Break Locator
Power Meter / Loss Test mode 1
Visual Fault Finder mode 1
Optical Return Loss
End to End Loss
Easy OTDR
OTDR Training
OTDR Assistant
Environmental

Operating Temperature: 0 to 50 degees C Storage Temperature: 40 to +60 degrees C
Humidity: 95% R.H from 0 to 40 degrees C
Power
AC: 100 240 Vrms
10% 50 60 Hz DC: 16 24 V
External Battery: NiMHtypically 8 hours continuous operation (minimum 4 hours) with Option #006. Charging time < 3 hours, non-operating
Low battery indicator
Battery charge status

If you’re selling your Agilent HP E6000C please fill out form on the right hand side of page.

Selling Agilent HP E6000B – We Buy New Used E6000B (‘s) Top Dollar Paid!

If you’re looking to Sell Agilent HP E6000B OTDR E6003A SM Fiber Module

The Agilent/HP E6000B Mainframe maximizes your network uptime by locating and characterizing faults quickly and accurately.

The combination of 16,000 data points and a minimum sample spacing of 8cm allows the powerful analysis algorithm to determine the exact location and characteristic of an event.

The Agilent/HP E6000B OTDR repeatedly outputs an optical pulse into the connected fiber and measures the reflections from this pulse. The trace displayed on the screen is a graph of this reflected power (backscatter) as a function of the distance along the fiber.

Events are changes in the fiber causing the trace to deviate from a straight line. Events can be Reflective or Non-Reflective.

Reflective Events occur when some of the pulse energy is reflected, for example at a connector. Non-Reflective Events occur at parts of the fiber where there is some loss but no light is reflected. Non-Reflective Events produce a dip on the trace.

The E6000B OTDR calculates the distance of such an “event” in the fiber from the time it takes the reflected signal to return. The further away an event is, the longer it takes for its reflection to return to the E6000B OTDR.

A fully automatic function is available and the E6000B OTDR sets itself up to achieve the best results for the measurements such as the location (distance) of events on the link, the end of the link or a break, the attenuation coefficient of the fiber in the link, the loss of an individual event or the total end-to-end loss of the link, the magnitude of the reflection (or reflectance) of an event, such as a connector, the cumulative loss to an event can be measured automatically.

The Agilent E6000B can operate through the supplied AC adapter between 100V and 240V ±10%, at a frequency in the range from 50 to 60 Hz. The maximum power consumption is 30VA with all options installed.

The Agilent E6000B can operate from a DC power source that supplies between 16V and 24V. The maximum power consumption during a quick charge is 30W with all options installed. Typical power consumption is below 8W.

Buying, Selling, Trading Agilent HP E6000B

Key Points:

Built in Applications
Built in multi fiber test
With template mode
One button operation
Automatic event adjustment
15 secs power up cycle
Automatic fiber characteristic

Brand Agilent / HP
Model E6000B
Description Mini OTDR Mainframe
Category OTDR
Sub Category N/A
Specifications:
User Interface Proprietary
Input Power Universal
Inter memory Up to 200 traces
Operating Temperature 0 to 50 deg C
Storage Temperature -40 to 60 deg C
Dimensions 194 mm H, 290 mm W, 75 mm D (7.7″ x 11.4″ x 3.0″)
Weight net < 2.9 kg (6.4 lbs)

E6003A Specifications:

Wavelength 1310/1550nm
Dynamic Range (dB) 35/34dB
Event Deadline 3m
Attenuation Dead Zone 10/12m
Recommended Application Metropolitan/Trunk
Fiber Type Single-Mode
Module E6003A

If you’re selling your Agilent HP E6000B please fill out form on the right hand side of page.

Selling Agilent HP E6000B – We Buy New Used E6000B (‘s) Top Dollar Paid!

If you’re looking to Sell Agilent HP E6000B OTDR w/ E6003B SM Fiber Module

The Agilent/HP E6000B Mainframe maximizes your network uptime by locating and characterizing faults quickly and accurately.

The combination of 16,000 data points and a minimum sample spacing of 8cm allows the powerful analysis algorithm to determine the exact location and characteristic of an event.

The Agilent/HP E6000B OTDR repeatedly outputs an optical pulse into the connected fiber and measures the reflections from this pulse. The trace displayed on the screen is a graph of this reflected power (backscatter) as a function of the distance along the fiber.

Events are changes in the fiber causing the trace to deviate from a straight line. Events can be Reflective or Non-Reflective.

Reflective Events occur when some of the pulse energy is reflected, for example at a connector. Non-Reflective Events occur at parts of the fiber where there is some loss but no light is reflected. Non-Reflective Events produce a dip on the trace.

The E6000B OTDR calculates the distance of such an “event” in the fiber from the time it takes the reflected signal to return. The further away an event is, the longer it takes for its reflection to return to the E6000B OTDR.

A fully automatic function is available and the E6000B OTDR sets itself up to achieve the best results for the measurements such as the location (distance) of events on the link, the end of the link or a break, the attenuation coefficient of the fiber in the link, the loss of an individual event or the total end-to-end loss of the link, the magnitude of the reflection (or reflectance) of an event, such as a connector, the cumulative loss to an event can be measured automatically.

The Agilent E6000B can operate through the supplied AC adapter between 100V and 240V ±10%, at a frequency in the range from 50 to 60 Hz. The maximum power consumption is 30VA with all options installed.

The Agilent E6000B can operate from a DC power source that supplies between 16V and 24V. The maximum power consumption during a quick charge is 30W with all options installed. Typical power consumption is below 8W.

Key Points:

Built in Applications
Built in multi fiber test
With template mode
One button operation
Automatic event adjustment
15 secs power up cycle
Automatic fiber characteristic

Brand Agilent / HP
Model E6000B
Description Mini OTDR Mainframe
Category OTDR
Sub Category N/A
Specifications:
User Interface Proprietary
Input Power Universal
Inter memory Up to 200 traces
Operating Temperature 0 to 50 deg C
Storage Temperature -40 to 60 deg C
Dimensions 194 mm H, 290 mm W, 75 mm D (7.7″ x 11.4″ x 3.0″)
Weight net < 2.9 kg (6.4 lbs)

Buying, Selling, Trading Agilent HP E6000B

Agilent E6008B
Central Wavelength 1310 nm ± 25 nm/1550 nm ± 5 nm
Applicable Fiber Singlemode
Pulsewidth 10 ns 100 ns 1µs 10 µs 20 µs
Dynamic Range 24/22 29/27 35/34 42/41 45/43
Event Deadzone 3m
Attenuation Deadzone 10/12m

Agilent E6006A Power Meter Submodule
Characteristics
Sensor element: InGaAs
Wavelength range: 800 ? 1650 nm
Calibrated wavelengths: 850 nm, 1300 nm,
1310 nm, 1550 nm, 1625 nm
(special wavelengths on request).
Power range: +10 to -70 dBm
Max. input power (damage level): +13
dBm/20 mW
Display Resolution: 0.01 dB
Display Units: dBm, dB, mW, µW, nW, pW
Display Contents
• Calibrated ? in nm
• Modulation frequency in Hz
• Reference value in dB
Display Updates per second: 3
Optical input: User-exchangeable
Connector Interface
Applicable fiber type: 9/125 µm, 50/125
µm, 62.5/125 µm
Specifications
Uncertainty at reference conditions:
± 3%
Power level: – 20 dBm
Continuous Wave (CW)
Wavelength: 1300±3 nm, 1310±3 nm,
1550±3 nm
Fiber type: 50/125 µm graded index,
Agilent/HMS-10 connector
Spectral bandwidth: up to 10 nm
Ambient temperature: +18 to + 28 °C
At day of calibration (add 0.3% for aging of
over one year; add 0.6% for aging of over
two years).
Total uncertainty: ± 5% ± 0.5 nW
(1310, 1550 nm)
Power level: +0 to ?50 dBm
Continuous Wave (CW)
Wavelength: 850±3 nm, 1300±3 nm,
1310±3 nm, 1550±3 nm,
Fiber type: SM to 50µm graded index
(add 2% to total uncertainty for fiber
62.5µm).
Straight and angled connectors
Ambient temperature: +10 to +40°C
Within 2 years after calibration
Supplementary Performance
Characteristics
• Automatic Zeroing Circuitry
• Automatic Ranging
• Modulation frequency
recognition (270 Hz, 1 kHz,
2 kHz) is available at power level
between +10 and ?45 dBm
(peak amplitude).
• Dual Wavelength measurement
is available at power levels
between +10 and ?45 dBm
(peak amplitude).
• Wavelength encoding recognition
(350 Hz, 550 Hz) is available at
power levels between +10 and ?45
dBm (peak amplitude).
• Reference value is presettable
from +30 to ?80 dBm
• Each calibrated wavelength has
its own reference memory.
• The actual display content can
be transferred to reference
memory(DISP?REF).
• Hold Data functionality
General Specifications
Dimensions: ca. 120 mm H x 40 mm W
x 25 mm D (4.7? x 1.6? x 1.0?)
Weight: <130g.
Operating Temperature: 0 to +50 °C
Storage Temperature: -40 to +60 °C
Humidity: 95% R.H. from 0°C to 40°C
non cond.

If you’re selling your Agilent HP E6000B please fill out form on the right hand side of page.

Selling Agilent HP E6000B – We Buy New Used E6000B (‘s) Top Dollar Paid!

If you’re looking to Sell Agilent HP E6000B OTDR w/ E6005A MM Fiber w/ VFL

The Agilent/HP E6000B Mainframe maximizes your network uptime by locating and characterizing faults quickly and accurately.

The combination of 16,000 data points and a minimum sample spacing of 8cm allows the powerful analysis algorithm to determine the exact location and characteristic of an event.

The Agilent/HP E6000B OTDR repeatedly outputs an optical pulse into the connected fiber and measures the reflections from this pulse. The trace displayed on the screen is a graph of this reflected power (backscatter) as a function of the distance along the fiber.

Events are changes in the fiber causing the trace to deviate from a straight line. Events can be Reflective or Non-Reflective.

Reflective Events occur when some of the pulse energy is reflected, for example at a connector. Non-Reflective Events occur at parts of the fiber where there is some loss but no light is reflected. Non-Reflective Events produce a dip on the trace.

The E6000B OTDR calculates the distance of such an “event” in the fiber from the time it takes the reflected signal to return. The further away an event is, the longer it takes for its reflection to return to the E6000B OTDR.

A fully automatic function is available and the E6000B OTDR sets itself up to achieve the best results for the measurements such as the location (distance) of events on the link, the end of the link or a break, the attenuation coefficient of the fiber in the link, the loss of an individual event or the total end-to-end loss of the link, the magnitude of the reflection (or reflectance) of an event, such as a connector, the cumulative loss to an event can be measured automatically.

The Agilent E6000B can operate through the supplied AC adapter between 100V and 240V ±10%, at a frequency in the range from 50 to 60 Hz. The maximum power consumption is 30VA with all options installed.

The Agilent E6000B can operate from a DC power source that supplies between 16V and 24V. The maximum power consumption during a quick charge is 30W with all options installed. Typical power consumption is below 8W.

Key Points:

Built in Applications
Built in multi fiber test
With template mode
One button operation
Automatic event adjustment
15 secs power up cycle
Automatic fiber characteristic

Buying, Selling, Trading Agilent HP E6000B

Brand Agilent / HP
Model E6000B
Description Mini OTDR Mainframe
Category OTDR
Sub Category N/A
Specifications:
Form Factor Module
Fiber Type Multimode
Wavelength Range 850nm to 1300nm
Maximum Dynamic Range 18dB
User Interface Proprietary
Input Power Universal
Inter memory Up to 200 traces
Operating Temperature 0 to 50 deg C
Storage Temperature -40 to 60 deg C
Dimensions 194 mm H, 290 mm W, 75 mm D (7.7″ x 11.4″ x 3.0″)
Weight net < 2.9 kg (6.4 lbs)

Agilent E6005A
Central Wavelength 850±30 nm/ 1300±30 nm
Applicable Fiber multimode 62.5 µm
Pulsewidth 10 ns 100 ns 1µs 10 µs
Dynamic Range 9/17 26/22 – /28 – /34
Event Deadzone 3m
Attenuation Deadzone 10m

If you’re selling your Agilent HP E6000B please fill out form on the right hand side of page.

Selling Agilent HP E6000B – We Buy New Used E6000B (‘s) Top Dollar Paid!

If you’re looking to Sell Agilent HP E6000B Mini OTDR MainFrame

The Agilent/HP E6000B Mainframe maximizes your network uptime by locating and characterizing faults quickly and accurately.

The combination of 16,000 data points and a minimum sample spacing of 8cm allows the powerful analysis algorithm to determine the exact location and characteristic of an event.

The Agilent/HP E6000B OTDR repeatedly outputs an optical pulse into the connected fiber and measures the reflections from this pulse. The trace displayed on the screen is a graph of this reflected power (backscatter) as a function of the distance along the fiber.

Events are changes in the fiber causing the trace to deviate from a straight line. Events can be Reflective or Non-Reflective.

Reflective Events occur when some of the pulse energy is reflected, for example at a connector. Non-Reflective Events occur at parts of the fiber where there is some loss but no light is reflected. Non-Reflective Events produce a dip on the trace.

The E6000B OTDR calculates the distance of such an “event” in the fiber from the time it takes the reflected signal to return. The further away an event is, the longer it takes for its reflection to return to the E6000B OTDR.

A fully automatic function is available and the E6000B OTDR sets itself up to achieve the best results for the measurements such as the location (distance) of events on the link, the end of the link or a break, the attenuation coefficient of the fiber in the link, the loss of an individual event or the total end-to-end loss of the link, the magnitude of the reflection (or reflectance) of an event, such as a connector, the cumulative loss to an event can be measured automatically.

The Agilent E6000B can operate through the supplied AC adapter between 100V and 240V ±10%, at a frequency in the range from 50 to 60 Hz. The maximum power consumption is 30VA with all options installed.

The Agilent E6000B can operate from a DC power source that supplies between 16V and 24V. The maximum power consumption during a quick charge is 30W with all options installed. Typical power consumption is below 8W.

Buying, Selling, Trading Agilent HP E6000B

Key Points:

Built in Applications
Built in multi fiber test
With template mode
One button operation
Automatic event adjustment
15 secs power up cycle
Automatic fiber characteristic

Brand Agilent / HP
Model E6000B
Description Mini OTDR Mainframe
Category OTDR
Sub Category N/A
User Interface Proprietary
Input Power Universal
Inter memory Up to 200 traces
Operating Temperature 0 to 50 deg C
Storage Temperature -40 to 60 deg C
Dimensions 194 mm H, 290 mm W, 75 mm D (7.7″ x 11.4″ x 3.0″)
Weight net < 2.9 kg (6.4 lbs)

If you’re selling your Agilent HP E6000B please fill out form on the right hand side of page.

Selling Agilent HP E6000A – We Buy New Used E6000A (‘s) Top Dollar Paid!

If you’re looking to Sell Agilent HP E6000A OTDR w/ E6003A SM E6006A PM

Agilent E6000A Mini OTDR Mainframe

The Agilent Mini-OTDR is the best selling product in Agilent’s portfolio of Optical Network Test Solutions for the installation, maintenance and operation of fiber networks.

The Mini-OTDR is designed to provide its users with the fastest tool available for installing and commissioning multiple fiber links and locating faults for fiber maintenance. This is accomplished through high measurement performance and an award winning simple user interface.
* Fiber Break Locator to quickly find breaks and bends.
* Locate and characterize splice and connector losses.
* Multifiber testing for fast high-count cable qualification.
* Perform power and loss measurement with the built-in light source and the power meter module.
* Graphical representation of measurement results in event tables, showing loss and reflection, and pass/fail results.
* Visual Fault Finder to check patch cords for light leakage.

Characteristics

Horizontal Parameters

* Start-km:
* 0 km to 400 km Span: 0.1 km to 400 km
* Readout resolution: 0.1 m
* Minimum sample spacing: 4 cm
* Refractive index: 1.00000 to 2.00000
* Length unit: km, ft, or miles
* Measurement points: up to 64000

Vertical Parameters

* Vertical scale:
* 0.1 to 10.0 dB/Div Read-out resolution: 0.001 dB
* Reflectance range: 14 dB to 60 dB
* Backscatter coefficient: 10 to 70 dB at 1 s

Pulsewidth

You can select any of the following pulsewidths: 10 ns, 30 ns, 100 ns, 300 ns, 1 s, 3 s, and 10 s (all modules). You can also select 5 ns for E6003C, 5A, 9A modules, and 20 s for E6003B, E6003C, E6008B, and E6013A.

With the E6005A module, you can select a pulsewidth from 5 ns to 100 ns at 850 nm, and from 5 ns to 10 s at 1300 nm.

With the E6009A module, you can select a pulsewidth from 5 ns to 100 ns at 850 nm, and from 5 ns to 1 s at 1300 nm.

Storage

* 3.5 floppy disk drive:
* for high density 720/1440 kByte floppy disks. MS-DOS format compatible. Reduced operating temperature of 5C to 45C, with 35% to 80% humidity at 40C. Memory Card: PCMCIA Type II. 440 MB with up to 13000 traces (typical with 64000 data points).
* Internal memory: SRAM up to 2 MB. Up to 300 traces (typical) with 4000 data points

OTDR Trace Formats

Trace format: compliant to the following Bellcore/Telcordia OTDR trace formats:

* GR 196, Revision 1.0
* GR 196, Revision 1.1
* SR-4731 Revision 2.0.
* Trace Information: 5 comment labels of up to 15 alphanumeric characters, and 5 comment fields of up to 41 alphanumeric characters are provided for each trace.
* Real-time clock and date

Scan Trace

* Type of events:
* reflective and nonreflective. Maximum number of events: 100.
* Threshold for non-reflective events: 0.0 to 5.0 dB, selectable in 0.01 dB steps.
* Threshold for reflective events: – 14.0 to ?65.0 dB, selectable in 0.1 dB steps.
* Threshold for fiber breaks: 0.1 to 10 dB, selectable in 0.1 dB steps.
* Fiber End Threshold: 0.1 to 20 dB, selectable in 0.1 dB steps.
*
* Display Color or monochrome VGA-LCD: 18.3 cm (7.2?)
* Display points: 640 x 480 Points
* Measurement update rate: two measurements per second in refresh mode

Interfaces

RS232C:

* Maximum transmission rate:
* 115200 bps Transmission time at 115200 bps for trace data: 4000 points at approx. 1 second; 64000 points at approx. 4 seconds.
* Centronics: Standard parallel port (SPP).
* Keyboard: PS2 (Min-DIN). For English Standard, PS2, or AT keyboard.

General

* Automatic setup analysis
* Instrument settings: storage and recall of user-selectable instrument settings.
* Laser safety class: All OTDR laser sources specified by this data sheet are classified as Class 1M according to IEC 60825-1 (2001).

The Visual Fault Finder Sub-Module E6007A complies with Class 2 according to IEC 60825-1 (2001).

All laser sources comply with 21 CFR 1040.10 except for deviations pursuant to Laser Notice No. 50, dated 2001-July-26

* Recommended module recalibration period:
* 2 years. (OTDR Modules and Power Meter only) Dimensions: 194 mm H, 290 mm W,
* 75 mm D (7.7? x 11.4? x 3.0?).
* Weight: net < 2.9 kg (6.4 lbs), typical, including battery pack and OTDR module.

Built-in Applications

* Automatic Multi Fiber Test
* Pass/Fail Test
* Fiber Break Locator
* Power Meter / Loss Test mode 1
* Visual Fault Finder mode 1
* Optical Return Loss
* End to End Loss
* Easy OTDR
* OTDR Training
* OTDR Assistant

Environmental

* Operating Temperature:
* 0 to 50 degees C Storage Temperature: 40 to +60 degrees C
* Humidity: 95% R.H from 0 to 40 degrees C

Power

* AC: 100 240 Vrms
* 10% 50 60 Hz DC: 16 24 V
* External Battery: NiMHtypically 8 hours continuous operation (minimum 4 hours) with Option #006. Charging time < 3 hours, non-operating
* Low battery indicator
* Battery charge status

Buying, Selling, Trading Agilent HP E6000A

E6003A Specifications:

Module
E6003A
Central Wavelength
1310nm ± 25 nm / 1550nm ± 25 nm
Applicable Fiber
Single Mode
Pulsewidth
10ns 10ns 1us 10us
Dynamic Range [dB]
19/17 24/22 30/29 35/34
Event Deadzone
3 m
Attenuation Deadzone
10/12m

Agilent E6006A Power Meter Submodule

Characteristics

Sensor element: InGaAs

Wavelength range: 800 – 1650 nm

Calibrated wavelengths: 850 nm, 1300 nm, 1310 nm, 1550 nm, 1625 nm (special wavelengths on request).

Power range: +10 to -70 dBm

Max. input power (damage level): +13 dBm/20 mW

Display Resolution: 0.01 dB

Display Units: dBm, dB, mW, µW, nW, pW

Display Contents
• Calibrated – in nm
• Modulation frequency in Hz
• Reference value in dB

Display Updates per second: 3

Optical input: User-exchangeable Connector Interface

Applicable fiber type: 9/125 µm, 50/125 µm, 62.5/125 µm

Specifications

Uncertainty at reference conditions: ± 3%

Power level: – 20 dBm Continuous Wave (CW)

Wavelength: 1300±3 nm, 1310±3 nm, 1550±3 nm

Fiber type: 50/125 µm graded index, Agilent/HMS-10 connector

Spectral bandwidth: up to 10 nm

Ambient temperature: +18 to + 28 °C

At day of calibration (add 0.3% for aging of over one year; add 0.6% for aging of over two years).

Total uncertainty: ± 5% ± 0.5 nW (1310, 1550 nm)

Power level: +0 to ?50 dBm Continuous Wave (CW)

Wavelength: 850±3 nm, 1300±3 nm, 1310±3 nm, 1550±3 nm,

Fiber type: SM to 50µm graded index (add 2% to total uncertainty for fiber 62.5µm).
Characteristics

• Automatic Zeroing Circuitry
• Automatic Ranging
• Modulation frequency recognition (270 Hz, 1 kHz, 2 kHz) is available at power level between +10 and ?45 dBm (peak amplitude).
• Dual Wavelength measurement is available at power levels between +10 and ?45 dBm (peak amplitude).
• Wavelength encoding recognition (350 Hz, 550 Hz) is available at power levels between +10 and ?45 dBm (peak amplitude).
• Reference value is presettable from +30 to ?80 dBm
• Each calibrated wavelength has its own reference memory.
• The actual display content can be transferred to reference memory(DISP?REF).
• Hold Data functionality
General Specifications

Dimensions: ca. 120 mm H x 40 mm W x 25 mm D (4.7? x 1.6? x 1.0?) Weight: <130g.

Operating Temperature: 0 to +50 °C

Storage Temperature: -40 to +60 °C

Humidity: 95% R.H. from 0°C to 40°C non cond

If you’re selling your Agilent HP E6000A please fill out form on the right hand side of page.

Selling Agilent HP E6000A – We Buy New Used E6000A (‘s) Top Dollar Paid!

If you’re looking to Sell Agilent HP E6000A SM MM Mini OTDR E6008B E6005A

Agilent E6000A Mini OTDR Mainframe

The Agilent Mini-OTDR is the best selling product in Agilent’s portfolio of Optical Network Test Solutions for the installation, maintenance and operation of fiber networks.

The Mini-OTDR is designed to provide its users with the fastest tool available for installing and commissioning multiple fiber links and locating faults for fiber maintenance. This is accomplished through high measurement performance and an award winning simple user interface.

Features
– High dynamic range: 40 dB
– Automatic fiber characterization
– Built-in multi-fiber test
– Fiber break locator mode
– Full remote control
– Simple one-button operation
– Context-sensitive on-line help
– Automatic event adjustment
– Front connector check
– Compliant to Bellcore GR-196-CORE trace format
– Stabilized continuous wave (CW) light source
– Minimum sampling resolution: 8cm
– 15 seconds power up cycle
– Small and light

Characteristics

Horizontal Parameters
– Start-km:
– 0 km to 400 km Span: 0.1 km to 400 km
– Readout resolution: 0.1 m
– Minimum sample spacing: 4 cm
– Refractive index: 1.00000 to 2.00000
– Length unit: km, ft, or miles
– Measurement points: up to 64000

Vertical Parameters
– Vertical scale:
– 0.1 to 10.0 dB/Div Read-out resolution: 0.001 dB
– Reflectance range: 14 dB to 60 dB
– Backscatter coefficient: 10 to 70 dB at 1 s

Storage
– 3.5 floppy disk drive:
– for high density 720/1440 kByte floppy disks. MS-DOS format compatible. Reduced operating temperature of 5C to 45C, with 35% to 80% humidity at 40C. Memory Card: PCMCIA Type II. 440 MB with up to 13000 traces (typical with 64000 data points).
– Internal memory: SRAM up to 2 MB. Up to 300 traces (typical) with 4000 data points

Interfaces

RS232C:
– Maximum transmission rate:
– 115200 bps Transmission time at 115200 bps for trace data: 4000 points at approx. 1 second; 64000 points at approx. 4 seconds.
– Centronics: Standard parallel port (SPP).
– Keyboard: PS2 (Min-DIN). For English Standard, PS2, or AT keyboard.

Buying, Selling, Trading Agilent HP E6000A

General
– Automatic setup analysis
– Instrument settings: storage and recall of user-selectable instrument settings.
– Laser safety class: All OTDR laser sources specified by this data sheet are classified as Class 1M according to IEC 60825-1 (2001).

Built-in Applications
– Automatic Multi Fiber Test
– Pass/Fail Test
– Fiber Break Locator
– Power Meter / Loss Test mode 1
– Visual Fault Finder mode 1
– Optical Return Loss
– End to End Loss
– Easy OTDR
– OTDR Training
– OTDR Assistant

Environmental
– Operating Temperature:
– 0 to 50 degees C Storage Temperature: 40 to +60 degrees C
– Humidity: 95% R.H from 0 to 40 degrees C

Power
– AC: 100 240 Vrms
– 10% 50 60 Hz DC: 16 24 V
– External Battery: NiMHtypically 8 hours continuous operation (minimum 4 hours) with Option #006. Charging time < 3 hours, non-operating
– Low battery indicator
– Battery charge status

E6005A Specifications:

Central Wavelength 850 nm ± 30 nm/1300 nm ± 30 nm
Applicable Fiber multimode 62.5 µm
Pulsewidth 10 ns 100 ns 1 µs 10 µs
Dynamic Range[dB] 19/17 26/22 – /28 – /34
Event Deadzone 3 m

E6008B Specifications:
Central Wavelength
1310 nm ± 25 nm/1550nm ± 5 nm
Applicable Fiber
single-mode
Pulsewidth
10 ns
100 ns
1 µs
10 µs
20 µs
Dynamic Range [dB]
24/22
29/27
35/34
42/41
45/43
Event Deadzone
3 m
Attenuation Deadzone
10/12m

If you’re selling your Agilent HP E6000A please fill out form on the right hand side of page.