Selling Agilent HP E6000C – We Buy New Used E6000C (‘s) Top Dollar Paid!

If you’re looking to Sell Agilent HP E6000C Mini OTDR With E6004A SM Module

The Agilent Mini-OTDR is the best selling product in Agilent’s portfolio of Optical Network Test Solutions for the installation, maintenance and operation of fiber networks.

The Mini-OTDR is designed to provide its users with the fastest tool available for installing and commissioning multiple fiber links and locating faults for fiber maintenance. This is accomplished through high measurement performance and an award winning simple user interface.

Fiber Break Locator to quickly find breaks and bends.

Locate and characterize splice and connector losses.

Multifiber testing for fast high-count cable qualification.

Perform power and loss measurement with the built-in light source and the power meter module.

Graphical representation of measurement results in event tables, showing loss and reflection, and pass/fail results.

Visual Fault Finder to check patch cords for light leakage.

Characteristics:

Horizontal Parameters

Start-km:
0 km to 400 km Span: 0.1 km to 400 km
Readout resolution: 0.1 m
Minimum sample spacing: 4 cm
Refractive index: 1.00000 to 2.00000
Length unit: km, ft, or miles
Measurement points: up to 64000

Vertical Parameters

Vertical scale
0.1 to 10.0 dB/Div Read-out resolution: 0.001 dB
Reflectance range: 14 dB to 60 dB
Backscatter coefficient: 10 to 70 dB at 1 s
Pulsewidth

You can select any of the following pulsewidths: 10 ns, 30 ns, 100 ns, 300 ns, 1 s, 3 s, and 10 s (all modules). You can also select 5 ns for E6003C, 5A, 9A modules, and 20 s for E6003B, E6003C, E6008B, and E6013A.
With the E6005A module, you can select a pulsewidth from 5 ns to 100 ns at 850 nm, and from 5 ns to 10 s at 1300 nm.
With the E6009A module, you can select a pulsewidth from 5 ns to 100 ns at 850 nm, and from 5 ns to 1 s at 1300 nm.

Buying, Selling, Trading Agilent HP E6000C
Storage

3.5 floppy disk drive: for high density 720/1440 kByte floppy disks. MS-DOS format compatible. Reduced operating temperature of 5C to 45C, with 35% to 80% humidity at 40C. Memory Card: PCMCIA Type II. 440 MB with up to 13000 traces (typical with 64000 data points).
Internal memory: SRAM up to 2 MB. Up to 300 traces (typical) with 4000 data points
OTDR Trace Formats:

Trace format: compliant to the following Bellcore/Telcordia OTDR trace formats:
GR 196, Revision 1.0
GR 196, Revision 1.1
SR-4731 Revision 2.0
Trace Information: 5 comment labels of up to 15 alphanumeric characters, and 5 comment fields of up to 41 alphanumeric characters are provided for each trace.
Real-time clock and date
Scan Trace:

Type of events:

Reflective and nonreflective. Maximum number of events: 100.
Threshold for non-reflective events: 0.0 to 5.0 dB, selectable in 0.01 dB steps.
Threshold for reflective events: – 14.0 to ?65.0 dB, selectable in 0.1 dB steps.
Threshold for fiber breaks: 0.1 to 10 dB, selectable in 0.1 dB steps.
Fiber End Threshold: 0.1 to 20 dB, selectable in 0.1 dB steps.
Display Color or monochrome VGA-LCD: 18.3 cm (7.2?)
Display points: 640 x 480 Points
Measurement update rate: two measurements per second in refresh mode
Interfaces:

RS232C: Maximum transmission rate: 115200 bps Transmission time at 115200 bps for trace data: 4000 points at approx. 1 second; 64000 points at approx. 4 seconds.
Centronics: Standard parallel port (SPP).
Keyboard: PS2 (Min-DIN). For English Standard, PS2, or AT keyboard.
General:

Automatic setup analysis
Instrument settings: storage and recall of user-selectable instrument settings.
Laser safety class: All OTDR laser sources specified by this data sheet are classified as Class 1M according to IEC 60825-1 (2001).
The Visual Fault Finder Sub-Module E6007A complies with Class 2 according to IEC 60825-1 (2001).
All laser sources comply with 21 CFR 1040.10 except for deviations pursuant to Laser Notice No. 50, dated 2001-July-26

Built-in Applications:

Automatic Multi Fiber Test
Pass/Fail Test
Fiber Break Locator
Power Meter / Loss Test mode 1
Visual Fault Finder mode 1
Optical Return Loss
End to End Loss
Easy OTDR
OTDR Training
OTDR Assistant
Environmental

Operating Temperature: 0 to 50 degees C Storage Temperature: 40 to +60 degrees C
Humidity: 95% R.H from 0 to 40 degrees C
Power

AC: 100 240 Vrms
10% 50 60 Hz DC: 16 24 V
External Battery: NiMHtypically 8 hours continuous operation (minimum 4 hours) with Option #006. Charging time < 3 hours, non-operating
Low battery indicator
Battery charge status

E6004A OTDR Module

Central Wavelength
1310 nm ± 25 nm/1550 nm ± 25 nm
Applicable Fiber
Single-mode
Pulsewidth
10 ns 100 ns 1 µs 10 µs
Dynamic Range [dB]
30/30
Event Deadzone
3 m
Attenuation Deadzone
10/12 m

If you’re selling your Agilent HP E6000C please fill out form on the right hand side of page.

Selling Agilent HP E6000B – We Buy New Used E6000B (‘s) Top Dollar Paid!

If you’re looking to Sell Agilent HP E6000B Mini OTDR SM MM w/ PM VFL

The Agilent/HP E6000B Mainframe maximizes your network uptime by locating and characterizing faults quickly and accurately.

The combination of 16,000 data points and a minimum sample spacing of 8cm allows the powerful analysis algorithm to determine the exact location and characteristic of an event.

The Agilent/HP E6000B OTDR repeatedly outputs an optical pulse into the connected fiber and measures the reflections from this pulse. The trace displayed on the screen is a graph of this reflected power (backscatter) as a function of the distance along the fiber.

Events are changes in the fiber causing the trace to deviate from a straight line. Events can be Reflective or Non-Reflective.

Reflective Events occur when some of the pulse energy is reflected, for example at a connector. Non-Reflective Events occur at parts of the fiber where there is some loss but no light is reflected. Non-Reflective Events produce a dip on the trace.

The E6000B OTDR calculates the distance of such an “event” in the fiber from the time it takes the reflected signal to return. The further away an event is, the longer it takes for its reflection to return to the E6000B OTDR.

A fully automatic function is available and the E6000B OTDR sets itself up to achieve the best results for the measurements such as the location (distance) of events on the link, the end of the link or a break, the attenuation coefficient of the fiber in the link, the loss of an individual event or the total end-to-end loss of the link, the magnitude of the reflection (or reflectance) of an event, such as a connector, the cumulative loss to an event can be measured automatically.

The Agilent E6000B can operate through the supplied AC adapter between 100V and 240V ±10%, at a frequency in the range from 50 to 60 Hz. The maximum power consumption is 30VA with all options installed.

The Agilent E6000B can operate from a DC power source that supplies between 16V and 24V. The maximum power consumption during a quick charge is 30W with all options installed. Typical power consumption is below 8W.

Buying, Selling, Trading Agilent HP E6000B

Key Points:

Built in Applications
Built in multi fiber test
With template mode
One button operation
Automatic event adjustment
15 secs power up cycle
Automatic fiber characteristic

Brand Agilent / HP
Model E6000B
Description Mini OTDR Mainframe
Category OTDR
Sub Category N/A
User Interface Proprietary
Input Power Universal
Inter memory Up to 200 traces
Operating Temperature 0 to 50 deg C
Storage Temperature -40 to 60 deg C
Dimensions 194 mm H, 290 mm W, 75 mm D (7.7″ x 11.4″ x 3.0″)
Weight net < 2.9 kg (6.4 lbs)

E6004A

Wavelength 1310/1550nm
Dynamic Range (dB) 30/30dB
Event Deadline 3m
Attenuation Dead Zone 10/12m
Recommended Application Metropolitan/Trunk
Fiber Type Single-Mode
Module E6004A

E6009A Specifications

Central Wavelength 850 nm ± 30 nm/1300 nm ± 30 nm
Applicable Fiber multimode 62.5 µm
Pulsewidth 10 ns 100 ns 1 µs
Dynamic Range [dB] 12/12
18/18
– /23
Event Deadzone 3 m
Attenuation Deadzone 10 m

E6006A Power Meter Module Specifications:
Sensor Element
InGaAs
Wavelength Range
800 – 1650 nm
Calibrated Wavelengths
850/1300/1310/1550/1625 nm
Power Range
+10 to -70 dBm
Max. Input Power
+13 dBm / 20 mW
Display Resolution
0.01 dB
Display Units
dBm, dB, mW, µW, nW, pW
Display Contents
Calibrated in nm
Modulation frequency in Hz
Reference vaule in dB
Applicable Fiber Type
9/1250 µm, 50/125 µm, 62.5/125 µm

If you’re selling your Agilent HP E6000B please fill out form on the right hand side of page.

Selling Agilent HP E6003A – We Buy New Used E6003A (‘s) Top Dollar Paid!

If you’re looking to Sell Agilent HP E6003A Singlemode OTDR Module

E6003A Singlemode Module Specifications:

Buying, Selling, Trading Agilent HP E6003A

Wavelength 1310/1550nm
Dynamic Range (dB) 35/34dB
Event Deadline 3m
Attenuation Dead Zone 10/12m
Recommended Application Metropolitan/Trunk
Fiber Type Single-Mode
Module E6003A

If you’re selling your Agilent HP E6003A please fill out form on the right hand side of page.

Selling Agilent HP E6009A – We Buy New Used E6009A (‘s) Top Dollar Paid!

If you’re looking to Sell Agilent HP E6009A Multimode OTDR Module
E6009A Specifications

Buying, Selling, Trading Agilent HP E6009A

Module E6009A
Central Wavelenght 850nm ± 30 nm / 1300 nm ± 30 nm
Applicable Fiber multimode 62.5 µm
Pulsewidth 10ns 100ns 1µs
Dynamic Range (dB) 12/12 18/18 -/23
Event Deadzone 3 m
Attenuaton Deadzone 10 m

If you’re selling your Agilent HP E6009A please fill out form on the right hand side of page.

Selling Agilent HP E6000B – We Buy New Used E6000B (‘s) Top Dollar Paid!

If you’re looking to Sell Agilent HP E6000B SM MM Fiber OTDR
Agilent E6000B

The Agilent/HP E6000B Mainframe maximizes your network uptime by locating and characterizing faults quickly and accurately.

The combination of 16,000 data points and a minimum sample spacing of 8cm allows the powerful analysis algorithm to determine the exact location and characteristic of an event.

The Agilent/HP E6000B OTDR repeatedly outputs an optical pulse into the connected fiber and measures the reflections from this pulse. The trace displayed on the screen is a graph of this reflected power (backscatter) as a function of the distance along the fiber.

Events are changes in the fiber causing the trace to deviate from a straight line. Events can be Reflective or Non-Reflective.

Reflective Events occur when some of the pulse energy is reflected, for example at a connector. Non-Reflective Events occur at parts of the fiber where there is some loss but no light is reflected. Non-Reflective Events produce a dip on the trace.

The E6000B OTDR calculates the distance of such an “event” in the fiber from the time it takes the reflected signal to return. The further away an event is, the longer it takes for its reflection to return to the E6000B OTDR.

A fully automatic function is available and the E6000B OTDR sets itself up to achieve the best results for the measurements such as the location (distance) of events on the link, the end of the link or a break, the attenuation coefficient of the fiber in the link, the loss of an individual event or the total end-to-end loss of the link, the magnitude of the reflection (or reflectance) of an event, such as a connector, the cumulative loss to an event can be measured automatically.

The Agilent E6000B can operate through the supplied AC adapter between 100V and 240V ±10%, at a frequency in the range from 50 to 60 Hz. The maximum power consumption is 30VA with all options installed.

The Agilent E6000B can operate from a DC power source that supplies between 16V and 24V. The maximum power consumption during a quick charge is 30W with all options installed. Typical power consumption is below 8W.

Key Points:

Built in Applications
Built in multi fiber test
With template mode
One button operation
Automatic event adjustment
15 secs power up cycle
Automatic fiber characteristic

Buying, Selling, Trading Agilent HP E6000B
E6003B Specifications:

Wavelength 1310/1550nm
Dynamic Range (dB) 40/39dB
Event Deadline 3m
Attenuation Dead Zone 10/12m
Recommended Application Metropolitan/Trunk
Fiber Type Single-Mode
Module E6003A

E6005A Specifications

Central Wavelength 850 nm ± 30 nm/1300 nm ± 30 nm
Applicable Fiber multimode 62.5 µm
Pulsewidth 10 ns 100 ns 1 µs 10 µs
Dynamic Range [dB] 19/17 26/22 – /28 – /34
Event Deadzone 3 m
Attenuation Deadzone 12/14 m

If you’re selling your Agilent HP E6000B please fill out form on the right hand side of page.

Selling Agilent HP 346B – We Buy New Used 346B (‘s) Top Dollar Paid!

If you’re looking to Sell Agilent HP 346B Noise Source

The HP 346B noise source is the ideal companion to HP’s noise figure
solutions. Since it is broadband (10 MHz to 18 GHz), it eliminates the necessity
for several sources at different frequency bands.

Buying, Selling, Trading Agilent HP 346B

The low SWR of the noise
source reduces a major source of measurement uncertainty; reflections of test
signals. The 346B’s high ENR (14dB to 16dB), low SWR, and variety of connectors
make it a general-purpose noise source.

If you’re selling your Agilent HP 346B please fill out form on the right hand side of page.

Selling Agilent HP E6005A – We Buy New Used E6005A (‘s) Top Dollar Paid!

If you’re looking to Sell Agilent HP E6005A Multimode OTDR Module

E6005A Specifications

Buying, Selling, Trading Agilent HP E6005A

Central Wavelength 850 nm ± 30 nm/1300 nm ± 30 nm
Applicable Fiber multimode 62.5 µm
Pulsewidth 10 ns 100 ns 1 µs 10 µs
Dynamic Range [dB] 19/17 26/22 – /28 – /34
Event Deadzone 3 m
Attenuation Deadzone 12/14 m

If you’re selling your Agilent HP E6005A please fill out form on the right hand side of page.

Selling Agilent HP E6012A – We Buy New Used E6012A (‘s) Top Dollar Paid!

If you’re looking to Sell Agilent HP E6012A SingleMode OTDR Module
E6012A Specifications

Buying, Selling, Trading Agilent HP E6012A

Central Wavelength 1550 nm ± 25 nm/1625 nm ± 20 nm
Applicable Fiber single-mode
Pulsewidth 10 ns 100 ns 1 µs 10 µs 20 µs
Dynamic Range [dB] 22/18 27/24 34/30 41/40 43/ –
Event Deadzone 3 m
Attenuation Deadzone 12/14 m

If you’re selling your Agilent HP E6012A please fill out form on the right hand side of page.

Selling Agilent HP E6000C – We Buy New Used E6000C (‘s) Top Dollar Paid!

If you’re looking to Sell Agilent HP E6000C SM MM Fiber OTDR w E6012A E6005A

The Agilent Mini-OTDR is the best selling product in Agilent’s portfolio of Optical Network Test Solutions for the installation, maintenance and operation of fiber networks.

The Mini-OTDR is designed to provide its users with the fastest tool available for installing and commissioning multiple fiber links and locating faults for fiber maintenance. This is accomplished through high measurement performance and an award winning simple user interface.

Fiber Break Locator to quickly find breaks and bends.

Locate and characterize splice and connector losses.

Multifiber testing for fast high-count cable qualification.

Perform power and loss measurement with the built-in light source and the power meter module.

Graphical representation of measurement results in event tables, showing loss and reflection, and pass/fail results.

Visual Fault Finder to check patch cords for light leakage.

Characteristics:

Horizontal Parameters

Start-km:
0 km to 400 km Span: 0.1 km to 400 km
Readout resolution: 0.1 m
Minimum sample spacing: 4 cm
Refractive index: 1.00000 to 2.00000
Length unit: km, ft, or miles
Measurement points: up to 64000

Vertical Parameters

Vertical scale
0.1 to 10.0 dB/Div Read-out resolution: 0.001 dB
Reflectance range: 14 dB to 60 dB
Backscatter coefficient: 10 to 70 dB at 1 s
Pulsewidth

You can select any of the following pulsewidths: 10 ns, 30 ns, 100 ns, 300 ns, 1 s, 3 s, and 10 s (all modules). You can also select 5 ns for E6003C, 5A, 9A modules, and 20 s for E6003B, E6003C, E6008B, and E6013A.
With the E6005A module, you can select a pulsewidth from 5 ns to 100 ns at 850 nm, and from 5 ns to 10 s at 1300 nm.
With the E6009A module, you can select a pulsewidth from 5 ns to 100 ns at 850 nm, and from 5 ns to 1 s at 1300 nm.
Storage

3.5 floppy disk drive: for high density 720/1440 kByte floppy disks. MS-DOS format compatible. Reduced operating temperature of 5C to 45C, with 35% to 80% humidity at 40C. Memory Card: PCMCIA Type II. 440 MB with up to 13000 traces (typical with 64000 data points).
Internal memory: SRAM up to 2 MB. Up to 300 traces (typical) with 4000 data points
OTDR Trace Formats:

Trace format: compliant to the following Bellcore/Telcordia OTDR trace formats:
GR 196, Revision 1.0
GR 196, Revision 1.1
SR-4731 Revision 2.0
Trace Information: 5 comment labels of up to 15 alphanumeric characters, and 5 comment fields of up to 41 alphanumeric characters are provided for each trace.
Real-time clock and date
Scan Trace:

Type of events:

Reflective and nonreflective. Maximum number of events: 100.
Threshold for non-reflective events: 0.0 to 5.0 dB, selectable in 0.01 dB steps.
Threshold for reflective events: – 14.0 to ?65.0 dB, selectable in 0.1 dB steps.
Threshold for fiber breaks: 0.1 to 10 dB, selectable in 0.1 dB steps.
Fiber End Threshold: 0.1 to 20 dB, selectable in 0.1 dB steps.
Display Color or monochrome VGA-LCD: 18.3 cm (7.2?)
Display points: 640 x 480 Points
Measurement update rate: two measurements per second in refresh mode
Interfaces:

RS232C: Maximum transmission rate: 115200 bps Transmission time at 115200 bps for trace data: 4000 points at approx. 1 second; 64000 points at approx. 4 seconds.
Centronics: Standard parallel port (SPP).
Keyboard: PS2 (Min-DIN). For English Standard, PS2, or AT keyboard.

Buying, Selling, Trading Agilent HP E6000C

General:

Automatic setup analysis
Instrument settings: storage and recall of user-selectable instrument settings.
Laser safety class: All OTDR laser sources specified by this data sheet are classified as Class 1M according to IEC 60825-1 (2001).
The Visual Fault Finder Sub-Module E6007A complies with Class 2 according to IEC 60825-1 (2001).
All laser sources comply with 21 CFR 1040.10 except for deviations pursuant to Laser Notice No. 50, dated 2001-July-26

Built-in Applications:

Automatic Multi Fiber Test
Pass/Fail Test
Fiber Break Locator
Power Meter / Loss Test mode 1
Visual Fault Finder mode 1
Optical Return Loss
End to End Loss
Easy OTDR
OTDR Training
OTDR Assistant
Environmental

Operating Temperature: 0 to 50 degees C Storage Temperature: 40 to +60 degrees C
Humidity: 95% R.H from 0 to 40 degrees C
Power
AC: 100 240 Vrms
10% 50 60 Hz DC: 16 24 V
External Battery: NiMHtypically 8 hours continuous operation (minimum 4 hours) with Option #006. Charging time < 3 hours, non-operating
Low battery indicator
Battery charge status

E6000C Specifications

Central Wavelength 1550 nm ± 25 nm/1625 nm ± 20 nm
Applicable Fiber single-mode
Pulsewidth 10 ns 100 ns 1 µs 10 µs 20 µs
Dynamic Range [dB] 22/18 27/24 34/30 41/40 43/ –
Event Deadzone 3 m
Attenuation Deadzone 12/14 m
E6005A Specifications

Central Wavelength 850 nm ± 30 nm/1300 nm ± 30 nm
Applicable Fiber multimode 62.5 µm
Pulsewidth 10 ns 100 ns 1 µs 10 µs
Dynamic Range [dB] 19/17 26/22 – /28 – /34
Event Deadzone 3 m
Attenuation Deadzone 12/14 m

If you’re selling your Agilent HP E6000C please fill out form on the right hand side of page.

Selling Agilent HP E6000C – We Buy New Used E6000C (‘s) Top Dollar Paid!

If you’re looking to Sell Agilent HP E6000C OTDR w/ E6012A SM Fiber Module

The Agilent Mini-OTDR is the best selling product in Agilent’s portfolio of Optical Network Test Solutions for the installation, maintenance and operation of fiber networks.

The Mini-OTDR is designed to provide its users with the fastest tool available for installing and commissioning multiple fiber links and locating faults for fiber maintenance. This is accomplished through high measurement performance and an award winning simple user interface.

Fiber Break Locator to quickly find breaks and bends.

Locate and characterize splice and connector losses.

Multifiber testing for fast high-count cable qualification.

Perform power and loss measurement with the built-in light source and the power meter module.

Graphical representation of measurement results in event tables, showing loss and reflection, and pass/fail results.

Visual Fault Finder to check patch cords for light leakage.

Characteristics:

Horizontal Parameters

Start-km:
0 km to 400 km Span: 0.1 km to 400 km
Readout resolution: 0.1 m
Minimum sample spacing: 4 cm
Refractive index: 1.00000 to 2.00000
Length unit: km, ft, or miles
Measurement points: up to 64000

Vertical Parameters

Vertical scale
0.1 to 10.0 dB/Div Read-out resolution: 0.001 dB
Reflectance range: 14 dB to 60 dB
Backscatter coefficient: 10 to 70 dB at 1 s
Pulsewidth

You can select any of the following pulsewidths: 10 ns, 30 ns, 100 ns, 300 ns, 1 s, 3 s, and 10 s (all modules). You can also select 5 ns for E6003C, 5A, 9A modules, and 20 s for E6003B, E6003C, E6008B, and E6013A.
With the E6005A module, you can select a pulsewidth from 5 ns to 100 ns at 850 nm, and from 5 ns to 10 s at 1300 nm.
With the E6009A module, you can select a pulsewidth from 5 ns to 100 ns at 850 nm, and from 5 ns to 1 s at 1300 nm.
Storage

3.5 floppy disk drive: for high density 720/1440 kByte floppy disks. MS-DOS format compatible. Reduced operating temperature of 5C to 45C, with 35% to 80% humidity at 40C. Memory Card: PCMCIA Type II. 440 MB with up to 13000 traces (typical with 64000 data points).
Internal memory: SRAM up to 2 MB. Up to 300 traces (typical) with 4000 data points
OTDR Trace Formats:

Trace format: compliant to the following Bellcore/Telcordia OTDR trace formats:
GR 196, Revision 1.0
GR 196, Revision 1.1
SR-4731 Revision 2.0
Trace Information: 5 comment labels of up to 15 alphanumeric characters, and 5 comment fields of up to 41 alphanumeric characters are provided for each trace.
Real-time clock and date

Buying, Selling, Trading Agilent HP E6000C
Scan Trace:

Type of events:

Reflective and nonreflective. Maximum number of events: 100.
Threshold for non-reflective events: 0.0 to 5.0 dB, selectable in 0.01 dB steps.
Threshold for reflective events: – 14.0 to ?65.0 dB, selectable in 0.1 dB steps.
Threshold for fiber breaks: 0.1 to 10 dB, selectable in 0.1 dB steps.
Fiber End Threshold: 0.1 to 20 dB, selectable in 0.1 dB steps.
Display Color or monochrome VGA-LCD: 18.3 cm (7.2?)
Display points: 640 x 480 Points
Measurement update rate: two measurements per second in refresh mode
Interfaces:

RS232C: Maximum transmission rate: 115200 bps Transmission time at 115200 bps for trace data: 4000 points at approx. 1 second; 64000 points at approx. 4 seconds.
Centronics: Standard parallel port (SPP).
Keyboard: PS2 (Min-DIN). For English Standard, PS2, or AT keyboard.
General:

Automatic setup analysis
Instrument settings: storage and recall of user-selectable instrument settings.
Laser safety class: All OTDR laser sources specified by this data sheet are classified as Class 1M according to IEC 60825-1 (2001).
The Visual Fault Finder Sub-Module E6007A complies with Class 2 according to IEC 60825-1 (2001).
All laser sources comply with 21 CFR 1040.10 except for deviations pursuant to Laser Notice No. 50, dated 2001-July-26

Built-in Applications:

Automatic Multi Fiber Test
Pass/Fail Test
Fiber Break Locator
Power Meter / Loss Test mode 1
Visual Fault Finder mode 1
Optical Return Loss
End to End Loss
Easy OTDR
OTDR Training
OTDR Assistant
Environmental

Operating Temperature: 0 to 50 degees C Storage Temperature: 40 to +60 degrees C
Humidity: 95% R.H from 0 to 40 degrees C
Power
AC: 100 240 Vrms
10% 50 60 Hz DC: 16 24 V
External Battery: NiMHtypically 8 hours continuous operation (minimum 4 hours) with Option #006. Charging time < 3 hours, non-operating
Low battery indicator
Battery charge status

E6000C Specifications

Central Wavelength 1550 nm ± 25 nm/1625 nm ± 20 nm
Applicable Fiber single-mode
Pulsewidth 10 ns 100 ns 1 µs 10 µs 20 µs
Dynamic Range [dB] 22/18 27/24 34/30 41/40 43/ –
Event Deadzone 3 m
Attenuation Deadzone 12/14 m

If you’re selling your Agilent HP E6000C please fill out form on the right hand side of page.