Current post: Selling Agilent HP E6000A – We Buy New Used E6000A (‘s) Top Dollar Paid!

Selling Agilent HP E6000A – We Buy New Used E6000A (‘s) Top Dollar Paid!

If you’re looking to Sell Agilent HP E6000A OTDR w/ E6003A SM E6006A PM

Agilent E6000A Mini OTDR Mainframe

The Agilent Mini-OTDR is the best selling product in Agilent’s portfolio of Optical Network Test Solutions for the installation, maintenance and operation of fiber networks.

The Mini-OTDR is designed to provide its users with the fastest tool available for installing and commissioning multiple fiber links and locating faults for fiber maintenance. This is accomplished through high measurement performance and an award winning simple user interface.
* Fiber Break Locator to quickly find breaks and bends.
* Locate and characterize splice and connector losses.
* Multifiber testing for fast high-count cable qualification.
* Perform power and loss measurement with the built-in light source and the power meter module.
* Graphical representation of measurement results in event tables, showing loss and reflection, and pass/fail results.
* Visual Fault Finder to check patch cords for light leakage.

Characteristics

Horizontal Parameters

* Start-km:
* 0 km to 400 km Span: 0.1 km to 400 km
* Readout resolution: 0.1 m
* Minimum sample spacing: 4 cm
* Refractive index: 1.00000 to 2.00000
* Length unit: km, ft, or miles
* Measurement points: up to 64000

Vertical Parameters

* Vertical scale:
* 0.1 to 10.0 dB/Div Read-out resolution: 0.001 dB
* Reflectance range: 14 dB to 60 dB
* Backscatter coefficient: 10 to 70 dB at 1 s

Pulsewidth

You can select any of the following pulsewidths: 10 ns, 30 ns, 100 ns, 300 ns, 1 s, 3 s, and 10 s (all modules). You can also select 5 ns for E6003C, 5A, 9A modules, and 20 s for E6003B, E6003C, E6008B, and E6013A.

With the E6005A module, you can select a pulsewidth from 5 ns to 100 ns at 850 nm, and from 5 ns to 10 s at 1300 nm.

With the E6009A module, you can select a pulsewidth from 5 ns to 100 ns at 850 nm, and from 5 ns to 1 s at 1300 nm.

Storage

* 3.5 floppy disk drive:
* for high density 720/1440 kByte floppy disks. MS-DOS format compatible. Reduced operating temperature of 5C to 45C, with 35% to 80% humidity at 40C. Memory Card: PCMCIA Type II. 440 MB with up to 13000 traces (typical with 64000 data points).
* Internal memory: SRAM up to 2 MB. Up to 300 traces (typical) with 4000 data points

OTDR Trace Formats

Trace format: compliant to the following Bellcore/Telcordia OTDR trace formats:

* GR 196, Revision 1.0
* GR 196, Revision 1.1
* SR-4731 Revision 2.0.
* Trace Information: 5 comment labels of up to 15 alphanumeric characters, and 5 comment fields of up to 41 alphanumeric characters are provided for each trace.
* Real-time clock and date

Scan Trace

* Type of events:
* reflective and nonreflective. Maximum number of events: 100.
* Threshold for non-reflective events: 0.0 to 5.0 dB, selectable in 0.01 dB steps.
* Threshold for reflective events: – 14.0 to ?65.0 dB, selectable in 0.1 dB steps.
* Threshold for fiber breaks: 0.1 to 10 dB, selectable in 0.1 dB steps.
* Fiber End Threshold: 0.1 to 20 dB, selectable in 0.1 dB steps.
*
* Display Color or monochrome VGA-LCD: 18.3 cm (7.2?)
* Display points: 640 x 480 Points
* Measurement update rate: two measurements per second in refresh mode

Interfaces

RS232C:

* Maximum transmission rate:
* 115200 bps Transmission time at 115200 bps for trace data: 4000 points at approx. 1 second; 64000 points at approx. 4 seconds.
* Centronics: Standard parallel port (SPP).
* Keyboard: PS2 (Min-DIN). For English Standard, PS2, or AT keyboard.

General

* Automatic setup analysis
* Instrument settings: storage and recall of user-selectable instrument settings.
* Laser safety class: All OTDR laser sources specified by this data sheet are classified as Class 1M according to IEC 60825-1 (2001).

The Visual Fault Finder Sub-Module E6007A complies with Class 2 according to IEC 60825-1 (2001).

All laser sources comply with 21 CFR 1040.10 except for deviations pursuant to Laser Notice No. 50, dated 2001-July-26

* Recommended module recalibration period:
* 2 years. (OTDR Modules and Power Meter only) Dimensions: 194 mm H, 290 mm W,
* 75 mm D (7.7? x 11.4? x 3.0?).
* Weight: net < 2.9 kg (6.4 lbs), typical, including battery pack and OTDR module.

Built-in Applications

* Automatic Multi Fiber Test
* Pass/Fail Test
* Fiber Break Locator
* Power Meter / Loss Test mode 1
* Visual Fault Finder mode 1
* Optical Return Loss
* End to End Loss
* Easy OTDR
* OTDR Training
* OTDR Assistant

Environmental

* Operating Temperature:
* 0 to 50 degees C Storage Temperature: 40 to +60 degrees C
* Humidity: 95% R.H from 0 to 40 degrees C

Power

* AC: 100 240 Vrms
* 10% 50 60 Hz DC: 16 24 V
* External Battery: NiMHtypically 8 hours continuous operation (minimum 4 hours) with Option #006. Charging time < 3 hours, non-operating
* Low battery indicator
* Battery charge status

Buying, Selling, Trading Agilent HP E6000A

E6003A Specifications:

Module
E6003A
Central Wavelength
1310nm ± 25 nm / 1550nm ± 25 nm
Applicable Fiber
Single Mode
Pulsewidth
10ns 10ns 1us 10us
Dynamic Range [dB]
19/17 24/22 30/29 35/34
Event Deadzone
3 m
Attenuation Deadzone
10/12m

Agilent E6006A Power Meter Submodule

Characteristics

Sensor element: InGaAs

Wavelength range: 800 – 1650 nm

Calibrated wavelengths: 850 nm, 1300 nm, 1310 nm, 1550 nm, 1625 nm (special wavelengths on request).

Power range: +10 to -70 dBm

Max. input power (damage level): +13 dBm/20 mW

Display Resolution: 0.01 dB

Display Units: dBm, dB, mW, µW, nW, pW

Display Contents
• Calibrated – in nm
• Modulation frequency in Hz
• Reference value in dB

Display Updates per second: 3

Optical input: User-exchangeable Connector Interface

Applicable fiber type: 9/125 µm, 50/125 µm, 62.5/125 µm

Specifications

Uncertainty at reference conditions: ± 3%

Power level: – 20 dBm Continuous Wave (CW)

Wavelength: 1300±3 nm, 1310±3 nm, 1550±3 nm

Fiber type: 50/125 µm graded index, Agilent/HMS-10 connector

Spectral bandwidth: up to 10 nm

Ambient temperature: +18 to + 28 °C

At day of calibration (add 0.3% for aging of over one year; add 0.6% for aging of over two years).

Total uncertainty: ± 5% ± 0.5 nW (1310, 1550 nm)

Power level: +0 to ?50 dBm Continuous Wave (CW)

Wavelength: 850±3 nm, 1300±3 nm, 1310±3 nm, 1550±3 nm,

Fiber type: SM to 50µm graded index (add 2% to total uncertainty for fiber 62.5µm).
Characteristics

• Automatic Zeroing Circuitry
• Automatic Ranging
• Modulation frequency recognition (270 Hz, 1 kHz, 2 kHz) is available at power level between +10 and ?45 dBm (peak amplitude).
• Dual Wavelength measurement is available at power levels between +10 and ?45 dBm (peak amplitude).
• Wavelength encoding recognition (350 Hz, 550 Hz) is available at power levels between +10 and ?45 dBm (peak amplitude).
• Reference value is presettable from +30 to ?80 dBm
• Each calibrated wavelength has its own reference memory.
• The actual display content can be transferred to reference memory(DISP?REF).
• Hold Data functionality
General Specifications

Dimensions: ca. 120 mm H x 40 mm W x 25 mm D (4.7? x 1.6? x 1.0?) Weight: <130g.

Operating Temperature: 0 to +50 °C

Storage Temperature: -40 to +60 °C

Humidity: 95% R.H. from 0°C to 40°C non cond

If you’re selling your Agilent HP E6000A please fill out form on the right hand side of page.