Selling Acterna MTS 8000 – We Buy New Used MTS 8000 (‘s) Top Dollar Paid!

If you’re looking to Sell Acterna MTS 8000 T-BERD 10G Transport Module

T-BERD/MTS 8000 (TB/MTS 8000) Transport module

As service providers expand their offerings into new data and wavelength services, test requirements are also expanding beyond traditional SONET and T-Carrier technologies into Data and Optical layer technologies. Service providers are now responsible for installing and maintaining new network elements and service types that were not present in legacy networks.

The T-BERD/MTS 8000 (TB/MTS 8000) Transport module addresses these trends by providing the necessary test functionality to support all of these services in one integrated module. Weighing less than 15 pounds and operating on battery power for up to two hours at 10 Gb/s line rates, the TB/MTS 8000 is conveniently sized and designed for field test applications.

The TB/MTS 8000 Transport module’s Ethernet configuration allows for Ethernet and IP test capabilities from all Ethernet interfaces – 10/100/1000 copper, optical Gigabit Ethernet (GigE), and 10GigE LAN-Phy and WAN-Phy. Key test applications of the TB/MTS 8000 include connectivity, throughput, and quality of service (QoS) testing for emerging IP networks. The TB/MTS 8000 also provides RFC 2544 testing for verification of Ethernet and IP conformance to service level agreements (SLAs).

The TB/MTS 8000 features a full dual-port capability for 10/100/1000 copper and optical GigE interfaces – with two transmitters (TX) and two receivers (RX) – allowing for the simultaneous testing of two Ethernet/VLAN or IP circuits. These circuits may be provisioned for two fully independent customers, or they may represent two routes in a single network.

The dual-port capability of the TB/MTS 8000 Transport module enables field technicians to perform three important types of testing during turn-up and first-line of maintenance:
– Simultaneous Circuit Testing: Testing of two independent circuits concurrently
– Network Element Wrap Testing: Testing an element from the client to the network side
– In-Service Troubleshooting: Monitoring from two different directions on the circuit

Dual-Port Test Applications
Simultaneous Circuit Testing
Each of the TB/MTS 8000 Transport module’s two Ethernet ports has its own transmitter and receiver, both of which are able to connect to the customer’s switc  or router. This enables field technicians to test separate Ethernet/VLAN or IP connections through the network.

In a multi-site network, technicians can use the TB/MTS 8000 to test two routes independently of one another. If the service is straightforward Ethernet transport, meaning no switching occurs, the traffic can be returned to the origination point by a simple hard loop at the far-end destination point. If the traffic is switched at the MAC (layer 2) or IP (layer 3) layers, then another TB/MTS 8000 test instrument is required to perform the loop at the far end. In the loopback testing scenario, the TB/MTS 8000 takes the source and destination MAC or IP addresses of the transmitting Ethernet frame or IP packet and swaps them, thereby ensuring that the originating traffic travels properly through the network back to its origination point. In addition to testing the connectivity of each route, the TB/MTS 8000 enables technicians to test the performance of specific class of service (CoS) applications, using VLAN-based or TOS/DSCP-based traffic prioritization schemes.

Buying, Selling, Trading Acterna MTS 8000

Testing Parallel Virtual Connections Simultaneously
The TB/MTS 8000 Transport module also enables technicians to test two routes between the same origination point and the same termination point. If a customer is experiencing different delays on two parallel routes, the TB/MTS 8000 can be used to establish two VLAN or IP connections, with different tags and user priorities on each port, to a remote site. This test setup allows for verification of the round trip delay (RTD) on each path independently to determine if the delay is the same on both routes, and to verify/compare the delay on the two different routes.

Testing Two Independent Routes Simultaneously
When installing service to two separate customers, service providers only need one dual-port TB/MTS 8000 Transport module to perform installation testing. The TB/MTS 8000 emulates the customer’s switch/router, sends IEEE-complaint Ethernet traffic, and performs RFC 2544 tests for both end customers. This allows the service provider to consistently and repeatedly test the Ethernet traffic at every route and to save time by turning-up two customer circuits simultaneously

Network Element Wrap Testing
The TB/MTS 8000 Transport module also supports network element wrap testing. This enables technicians to pre-qualify a switch or router before bringing it into service. Full Gigabit Ethernet (1 GigE) throughput testing can be accomplished by connecting a single TB/MTS 8000 to two separate ports on both sides of the network element – client side and network side.

In addition, sub-rate line cards can be verified at different rates other than the network rate. For example, technicians can connect one TB/MTS 8000 port to the 10/100 Mb/s client card and the other TB/MTS 8000 port to the 1 GigE (1000 Mb/s) network card and perform throughput testing through the network element. This ensures that the network element backplane can sufficiently buffer and pass incoming traffic, without dropping any frames/packets. The TB/MTS 8000 can perform RFC 2544 testing to verify the configuration of the network element and the throughput of its line cards, as well as ensure consistent backplane functionality in both directions.

With this developing market trend, the TB/MTS 8000 Transport module is well-suited to enable technicians to use one test set to turn up services ranging from 10/100/1000 copper Ethernet, optical GigE, and optical 10 GigE – all from a single module. In addition, with its dual-port configuration, the TB/MTS 8000  provides a comprehensive and robust turn-up tool, thereby minimizing follow-on installation and maintenance issues.

 

If you’re selling your Acterna MTS 8000 please fill out form on the right hand side of page.

Selling Acterna MTS 8000 – We Buy New Used MTS 8000 (‘s) Top Dollar Paid!

If you’re looking to Sell Acterna MTS 8000 T-BERD Transport Module

T-BERD/MTS 8000 (TB/MTS 8000) Transport module

As service providers expand their offerings into new data and wavelength services, test requirements are also expanding beyond traditional SONET and T-Carrier technologies into Data and Optical layer technologies. Service providers are now responsible for installing and maintaining new network elements and service types that were not present in legacy networks.

The T-BERD/MTS 8000 (TB/MTS 8000) Transport module addresses these trends by providing the necessary test functionality to support all of these services in one integrated module. Weighing less than 15 pounds and operating on battery power for up to two hours at 10 Gb/s line rates, the TB/MTS 8000 is conveniently sized and designed for field test applications.

The TB/MTS 8000 Transport module’s Ethernet configuration allows for Ethernet and IP test capabilities from all Ethernet interfaces – 10/100/1000 copper, optical Gigabit Ethernet (GigE), and 10GigE LAN-Phy and WAN-Phy. Key test applications of the TB/MTS 8000 include connectivity, throughput, and quality of service (QoS) testing for emerging IP networks. The TB/MTS 8000 also provides RFC 2544 testing for verification of Ethernet and IP conformance to service level agreements (SLAs).

The TB/MTS 8000 features a full dual-port capability for 10/100/1000 copper and optical GigE interfaces – with two transmitters (TX) and two receivers (RX) – allowing for the simultaneous testing of two Ethernet/VLAN or IP circuits. These circuits may be provisioned for two fully independent customers, or they may represent two routes in a single network.

The dual-port capability of the TB/MTS 8000 Transport module enables field technicians to perform three important types of testing during turn-up and first-line of maintenance:
– Simultaneous Circuit Testing: Testing of two independent circuits concurrently
– Network Element Wrap Testing: Testing an element from the client to the network side
– In-Service Troubleshooting: Monitoring from two different directions on the circuit

Buying, Selling, Trading Acterna MTS 8000

Dual-Port Test Applications
Simultaneous Circuit Testing
Each of the TB/MTS 8000 Transport module’s two Ethernet ports has its own transmitter and receiver, both of which are able to connect to the customer’s switc  or router. This enables field technicians to test separate Ethernet/VLAN or IP connections through the network.

In a multi-site network, technicians can use the TB/MTS 8000 to test two routes independently of one another. If the service is straightforward Ethernet transport, meaning no switching occurs, the traffic can be returned to the origination point by a simple hard loop at the far-end destination point. If the traffic is switched at the MAC (layer 2) or IP (layer 3) layers, then another TB/MTS 8000 test instrument is required to perform the loop at the far end. In the loopback testing scenario, the TB/MTS 8000 takes the source and destination MAC or IP addresses of the transmitting Ethernet frame or IP packet and swaps them, thereby ensuring that the originating traffic travels properly through the network back to its origination point. In addition to testing the connectivity of each route, the TB/MTS 8000 enables technicians to test the performance of specific class of service (CoS) applications, using VLAN-based or TOS/DSCP-based traffic prioritization schemes.

Testing Parallel Virtual Connections Simultaneously
The TB/MTS 8000 Transport module also enables technicians to test two routes between the same origination point and the same termination point. If a customer is experiencing different delays on two parallel routes, the TB/MTS 8000 can be used to establish two VLAN or IP connections, with different tags and user priorities on each port, to a remote site. This test setup allows for verification of the round trip delay (RTD) on each path independently to determine if the delay is the same on both routes, and to verify/compare the delay on the two different routes.

Testing Two Independent Routes Simultaneously
When installing service to two separate customers, service providers only need one dual-port TB/MTS 8000 Transport module to perform installation testing. The TB/MTS 8000 emulates the customer’s switch/router, sends IEEE-complaint Ethernet traffic, and performs RFC 2544 tests for both end customers. This allows the service provider to consistently and repeatedly test the Ethernet traffic at every route and to save time by turning-up two customer circuits simultaneously

Network Element Wrap Testing
The TB/MTS 8000 Transport module also supports network element wrap testing. This enables technicians to pre-qualify a switch or router before bringing it into service. Full Gigabit Ethernet (1 GigE) throughput testing can be accomplished by connecting a single TB/MTS 8000 to two separate ports on both sides of the network element – client side and network side.

In addition, sub-rate line cards can be verified at different rates other than the network rate. For example, technicians can connect one TB/MTS 8000 port to the 10/100 Mb/s client card and the other TB/MTS 8000 port to the 1 GigE (1000 Mb/s) network card and perform throughput testing through the network element. This ensures that the network element backplane can sufficiently buffer and pass incoming traffic, without dropping any frames/packets. The TB/MTS 8000 can perform RFC 2544 testing to verify the configuration of the network element and the throughput of its line cards, as well as ensure consistent backplane functionality in both directions.

With this developing market trend, the TB/MTS 8000 Transport module is well-suited to enable technicians to use one test set to turn up services ranging from 10/100/1000 copper Ethernet, optical GigE, and optical 10 GigE – all from a single module. In addition, with its dual-port configuration, the TB/MTS 8000  provides a comprehensive and robust turn-up tool, thereby minimizing follow-on installation and maintenance issues.

If you’re selling your Acterna MTS 8000 please fill out form on the right hand side of page.

Selling JDSU Acterna 50600 – We Buy New Used 50600 (‘s) Top Dollar Paid!

If you’re looking to Sell JDSU Acterna 50600 PM SM MM Power Meter Module

Wavetek 50600 Singlemode Multimode Power Meter Module

Buying, Selling, Trading JDSU Acterna 50600

Form Factor
Module (proprietary interface/bus)
Sensor Type
InGaAs
Number of Channels
1 ch
Minimum Wavelength
800 nm
Maximum Wavelength
1650 nm
Minimum Power
0.0001 uW
Maximum Power
0.0031623 Watts
Power Resolution
0.01 dBm
Measurement Accuracy
0.331128782231572 %

If you’re selling your JDSU Acterna 50600 please fill out form on the right hand side of page.

Selling JDSU MTS-6000 – We Buy New Used MTS-6000 (‘s) Top Dollar Paid!

If you’re looking to Sell JDSU MTS-6000 OTDR w/ 8126 MR VFL SM Fiber

JDSU MTS-6000 Compact Optical Test Platform Mainframe
Key Features:

Compact, lightweight, and highly integrated platform
More than 40 application modules already supported for, multimode and single-mode
Exceeds Telcordia specifications for ruggedness, drop, testing, and extended battery life
Compatible with plug-in modules from the MTS-51001, and T-BERD 8000

Applications

Performs multimode and, single-mode OTDR and optical loss, test (bidirectional)
Conducts connector inspection and, continuity testing
Finds faults and identifies traffic
Tests FTTx/PON and CWDM, networks
Performs fiber dispersion testing, (PMD/CD/AP) for 10G/10GE/40G
Allows for use of talk set/data port, for automated end-to-end, communication and unit control
Generates proof-of-performance, reports
The JDSU MTS-6000 is a highly integrated test platform designed for all, phases of the fiber network life cycle. It provides field service technicians with the, highest levels of performance and upgradeability on the market today.

The modular design of the MTS-6000 offers an extensive portfolio of test, functionality with over 40 different fiber modules supporting a wide range of, applications. The versatility of the MTS-6000 allows technicians to standardize, using one type of test equipment and then introduce new testing capabilities in, the field without incurring additional training or device costs.

The MTS-6000 is compatible with our existing fiber module product line, so, technicians can exchange plug-in modules between the T-BERD-8000 Scalable, Optical Test Platform and the MTS-6000 , in the field and without the need for, additional tools. To ensure the highest level of return on your capital investment, for test equipment, an extension allows you to upgrade existing OTDR modules, from the MTS-5100 for use with the MTS-6000 .

To ensure the highest-level return on investment for your test equipment, upgrade, existing optical time domain reflectometer (OTDR) modules from the MTS-5100, (with an extension) for use with the MTS-6000 .
Ideal for Field Testing

The MTS-6000 is a highly integrated platform with a single module slot and, the option to extend internal memory up to 1 gigabyte. The platform features an, intuitive graphical user interface (GUI) shown on a large 8.4 inch transreflective, color display (with an optional touchscreen) to improve viewing under any, condition. The high capacity Lithium ion battery adds extended life.

OTDR and IL/ORL Testing
A Wide Range of OTDR Modules
The JDSU OTDR plug-in module family provides a wide range of highperformance, OTDRs. Over 40 field-interchangeable modules are compatible with, the MTS-6000 for testing and troubleshooting any multimode or single-mode, network. The OTDR family includes six lines of OTDRs featuring:

New wavelengths to cover 1383 nm (CWDM) and 1490 nm (FTTx)
Highest dynamic range up to 50 dB
Shortest dead zones down to 0.5 m in multimode and 0.8 m in singlemode
Fastest scan speed at 0.1 s in real-time mode

Buying, Selling, Trading JDSU MTS-6000

From Simple Fault Locator to Expert OTDR…
The fault locator boosts productivity in the field by providing:

Fast detection
Precise fault location
One-button automation
No specific settings required
Distance, loss, and ORL measurements
The expert mode offers high-level trace analysis possibilities, making your, MTS-6000 platform a powerful instrument for commissioning and troubleshooting, by offering:

Manual settings (pulse, acquisition time, resolution, distance range)
Manual addition and deletion of events
Manual slopes, splices, and reflectances measurement

Ideal for End-to-End Commissioning
OTDR bidirectional testing is required to obtain true and accurate splice loss, readings. JDSU has developed an innovative automatic bidirectional analysis, function that is integrated directly into the MTS-6000 platform, saving at least, 50 percent of the time required for traditional bidirectional analysis.

Offers communication between two units via the link under test to set up the, same optimized acquisition parameters
Displays and saves automatic acquisitions in both directions on both units
Eliminates operator error
This solution was developed to help network operators and dark fiber providers, characterize, maintain, and troubleshoot CWDM systems from short- to mediumhaul, fiber networks.
Insertion Loss and Optical Return Loss Testing

Measures bidirectional IL, ORL, and fiber length
Offers one-button automated testing
Compatible with the OFI-2000 Multifunction Loss Test Set
Specifications
Specifications for Typical 25°C
Display
TFT color, 8.4 in LCD, 800 x 600, high-visibility (standard)
Touchscreen,TFT color, 8.4 in LCD, 800 x 600, high-visibility
(optional)
Storage and I/O Interfaces
Internal memory 1000 test results
Extended memory (optional) Minimum 1 GB (optional)
2x USB V1.1, 1x RJ45 Ethernet
Power Supply
Battery type Standard removable Li-ion batteries
AC/DC adapter Input 100–240 V, 50–60 Hz,
Output 19 V DC/3.1 A
Operation time Up to 11 hrs with standard display,
Telcordia GR-196-CORE
Size and Weight
Mainframe with one plug-in module
and battery (L x H x W) 285 x 195 x 93 mm
(11.2 x 7.7 x 3.7 in)
Mainframe only (without battery
and module) 2.4 kg (5.3 lb)
Mainframe (with one plug-in module
and battery) 3.4 kg (7.5 lb)
Environmental Specifications
Operating temperature range
on mains (no options) –20 to +50°C
(–4 to 122°F)
Operating temperature range (all
options) 0 to +40°C
(32 to 104°F)
Storage temperature range –20 to +60°C (–4 to 140°F)
Humidity, non-condensing 95%
Base Unit Optical Interfaces (optional)
Power Meter
Power level +10 to –60 dBm
Calibrated wavelengths 850, 1310, and 1550 nm
Connector type Universal push/pull (UPP
Talkset
Wavelength 1550 nm ±20 nm
Dynamic range 45 dB
Function With data/file transfer
Laser safety Class 1M laser
Connector type Field interchangeable
Optical Return Loss
Selectable wavelength 1310 / 1550 nm
Measurement range 0 dB to 45 dB
Measurement uncertainty ± 1 dB
Display resolution 0.01 dB
Visual Fault Locator
Wavelength 635 nm ±15 nm
Output power level <1 mW
Laser safety Class 2 laser
Connector type Universal push/pull (UPP)
Continuous Wave Light Source
Wavelengths (selection) 1310, 1550, and 1625 nm
Output power level –3.5 dBm
Stability in 15 min ± 0.02 dB
Stability in 8 hrs ± 0.2 dB
Laser safety Class 1M laser
Connector type Field interchangeable
Video Inspection Scope (via USB)
Magnification 250X and 400X, through the USB port

8126 MR (Medium Range) Module

Specifications:
Dynamic Range
40.0 dB
Wavelengths (nm)
1310, 1550
Min.Pulse Width
3 nsec
Max Pulse Width
20 usec
Distance Range Min.
2.60 m
Distance Range Max.
380.00 km
Distance Resolution
4 cm sampling resolution

If you’re selling your JDSU MTS-6000 please fill out form on the right hand side of page.

Selling Wavetek Acterna JDSU 5026DR – We Buy New Used 5026DR (‘s) Top Dollar Paid!

If you’re looking to Sell Wavetek Acterna JDSU 5026DR Fiber OTDR Module VFL

5026 DR Medium Range / High Resolution Single mode 1310/1550 nm Module

Buying, Selling, Trading Wavetek Acterna JDSU 5026DR

Central wavelength 1310/1550 nm
± 20 nm
Laser safety class (21 CFR) Class 1
Pulse width 5 ns to 10 ìs
Distance range Up to 260 km
RMS dynamic range 37 dB/35 dB
Event dead zone 1 m
Attenuation dead zone 8 m

If you’re selling your Wavetek Acterna JDSU 5026DR please fill out form on the right hand side of page.

Selling Acterna 5026 – We Buy New Used 5026 (‘s) Top Dollar Paid!

If you’re looking to Sell Acterna 5026 SR Short Range SingleMode OTDR Module

Acterna Wavetek 5026 SR Short Range Singlemode 1310/1550 nm Module:

Buying, Selling, Trading Acterna 5026

Central Wavelength: 1310nm-1550nm
Fiber Type: Singlemode
Pulse Width: 10ns-10us
Distance Range: Up to 260 km
RMS Dynamic Range: 31dB, 29dB
Event Dead Zone: 4 m
Attenuation Dead Zone: 25 m

If you’re selling your Acterna 5026 please fill out form on the right hand side of page.

Selling Wavetek MTS-5100e – We Buy New Used MTS-5100e (‘s) Top Dollar Paid!

If you’re looking to Sell Wavetek MTS-5100e SM Fiber OTDR w/ 5026 SR

Advanced modular tester for high precision FTTx testing
The unique JDSU MTS-5100e is a fiber tester with a range of plug-in modules providing a comprehensive, integrated solution for OTDR and power meters with talk set option testing in one field-rugged instrument. Powerful, easy to use and highly cost-effective, MTS-5100e is designed to push the boundaries of field test productivity for network installers, operators and maintenance teams.

A wide range of field-interchangeable modules are available for the MTS-5100eo platform, including OTDRs for multimode (MM), very short haul/FTTx (VSR), short range (SRe), medium haul (DR), long haul (HD), very long haul (VHD), and 1625 nm, visual fault locator, and a range of light sources and power meters with talk set option.

JDSU’s optical time domain reflectometer (OTDR) and loss test (LTS) plug-in modules are compact, yet powerful additions to the MTS-5100e family of testers.

The JDSU MTS-5100eo offers the industry’s fastest, highest performance solutions of any OTDR field instrument on the market. Both the OTDR and LTS modules deliver high accuracy, cost effective, reliable testing for the installation and maintenance of FTTx networks.

Highlights

Wide range of OTDR and OLTS modules covering every application with two fast field interchangeable slots for modules
The ONLY platform highly visible in bright sunlight, this NEW high visibility screen option means the MTS-5100eo can be used in any lighting condition
From LAN (1.5 m event dead zone) to very long haul applications (44 dB dynamic range)
High performance testing (up to 128,000 acquisition points with 0.1 s real-time sweep)
Maximum portability (3.5 kg) and up to 16 hours battery operation (Telcordia GR196)
A complete range of PC software to enhance your OTDR reporting capabilities reducing cable acceptance reporting by up to 70%

The JDSU MTS-5100eo is the fastest, most reliable and accurate OTDR on the market

Together, the module’s automation and rapid testing features offer impressive time savings for companies involved in commissioning and locating faults in FTTx networks.

Maximizing field productivity
The most important prerequisites for testing in the field are ease-of-use and speed of acquisition. The OTDR module ensures maximum test productivity by providing one-button, automated operation for all of its critical test routines and a very high data acquisition speed of 40 dB in seconds.

Delivering the industry’s highest performance OTDR
The MTS-5100eo module is the fastest and most accurate OTDR to-date. It offers a dynamic range of up to 44 dB at 1550 nm and boasts a 0.1 second sweep time. As part of the MTS-5100eo, the OTDR module has a test capability of more than 200 km and can measure up to 128,000 separate data points with 4 cm sampling resolution. The product’s short deadzone enables the user to differentiate events down to 1 meter.

Optimized functions for in-depth analysis/operation
The OTDR’s bidirectional analysis capability enables true splice loss measurement with both end traces. Its multiple trace management feature greatly assists the process of proactively managing fiber problems and helps compare different current and stored measurements for in-depth analysis. A powerful macro function enables users to perform a series of tests without ongoing user intervention.

Suitable for every skill level
Whatever the user’s skill level, the OTDR module and MTS-5100eo instrument combination can rise to the challenge. Direct access keys ensure that users can access all the instrument’s sophisticated features via a highly intuitive interface and by a comprehensive set up and results screen. The OTDR module delivers complete trace analysis, with a direct link between trace and table.

Enhanced reporting power
Powerful instruments require powerful reporting tools. The OTDR and loss test set come with the most complete analysis and reporting software.

The package supports direct Ethernet transfer to a PC running JDSU’s OFS-100 Optical Fiber Trace Software or OFS-200 Optical Fiber Cable Software. This enables users to perform automatic multiple trace analysis and print out cable test results in batches, for fast generation of dedicated acceptance reports.

Buying, Selling, Trading Wavetek MTS-5100e

Technical specifications

Display
Passive color, 7.8 inches, LCD 640 × 480
Active TFT color, 8.4 inches, LCD 640 × 480,
Languages
English, French, German, Spanish, Portuguese, Italian, Chinese, Taiwanese, Russian, Korean, Japanese, Turkish
Weight
MTS-5100eo 3.5 kg (7.7 lb) including 1 module and 1 battery
Size
MTS-5100eo 300 × 235 × 90 mm
11.8 × 9.25 × 3.5 in
Input/Output
MTS-5100eo RS-232-C, Centronics interface, external keyboard (optional), Ethernet interface (optional)
Power supply AC or internal removable NiMH batteries
Operation time up to 16 hours with 2 batteries (Bellcore GR-196)
Internal charger Yes (external charger available)
Charging time < 3 hours per battery
DC input 11 to 14 V
AC adapter
MTS-5100eo Input 100-250 V, 50-60 Hz, 1.6 A, Output 12 V DC / 4.2 A
Results display dBm, dBr, nW, ìW, mW
Temperature range
Operating AC Power
(no options) –20 °C to 50 °C (–4 °F to +122 °F)
Operating with
all options 0 °C to 40 °C (+32 °F to +104 °F)
Storage –20 °C to 60 °C (–4 °F to +140 °F)
Humidity 95% without condensing
EMI/ESD CE compliant

Acterna 5026 SR Short Range Singlemode 1310/1550 nm Module:

Central Wavelength: 1310nm-1550nm
Fiber Type: Singlemode
Pulse Width: 10ns-10us
Distance Range: Up to 260 km
RMS Dynamic Range: 31dB, 29dB
Event Dead Zone: 4 m
Attenuation Dead Zone: 25 m

If you’re selling your Wavetek MTS-5100e please fill out form on the right hand side of page.

Selling JDSU T-BERD 6000 – We Buy New Used 6000 (‘s) Top Dollar Paid!

If you’re looking to Sell JDSU T-BERD 6000 OTDR w/ 8126 HD Module

JDSU T-BERD 6000 Compact Optical Test Platform Mainframe

Key Features:

Compact, lightweight, and highly integrated platform
More than 40 application modules already supported for, multimode and single-mode
Built-in VFL, power meter, LTS, ORL, and video inspection, scope options
Choose from IL/ORL,OTDR,PMD,CD, AP and/or WDM, plug-ins
Exceeds Telcordia specifications for ruggedness, drop, testing, and extended battery life
Compatible with plug-in modules from the MTS-51001, and T-BERD 8000
Applications

Performs multimode and, single-mode OTDR and optical loss, test (bidirectional)
Conducts connector inspection and, continuity testing
Finds faults and identifies traffic
Tests FTTx/PON and CWDM, networks
Performs fiber dispersion testing, (PMD/CD/AP) for 10G/10GE/40G
Allows for use of talk set/data port, for automated end-to-end, communication and unit control
Generates proof-of-performance, reports
The JDSU T-BERD 6000 is a highly integrated test platform designed for all, phases of the fiber network life cycle. It provides field service technicians with the, highest levels of performance and upgradeability on the market today.

The modular design of the T-BERD 6000 offers an extensive portfolio of test, functionality with over 40 different fiber modules supporting a wide range of, applications. The versatility of the T-BERD 6000 allows technicians to standardize, using one type of test equipment and then introduce new testing capabilities in, the field without incurring additional training or device costs.

The T-BERD 6000 is compatible with our existing fiber module product line, so, technicians can exchange plug-in modules between the T-BERD-8000 Scalable, Optical Test Platform and the T-BERD 6000, in the field and without the need for, additional tools. To ensure the highest level of return on your capital investment, for test equipment, an extension allows you to upgrade existing OTDR modules, from the MTS-5100 for use with the T-BERD 6000.

To ensure the highest-level return on investment for your test equipment, upgrade, existing optical time domain reflectometer (OTDR) modules from the MTS-5100, (with an extension) for use with the T-BERD 6000.

Ideal for Field Testing

The T-BERD 6000 is a highly integrated platform with a single module slot and, the option to extend internal memory up to 1 gigabyte. The platform features an, intuitive graphical user interface (GUI) shown on a large 8.4 inch transreflective, color display (with an optional touchscreen) to improve viewing under any, condition. The high capacity Lithium ion battery adds extended life. Other, features include an optional video inspection scope (via USB port), and optional, built-in optical test functions, such as a visual fault locator (VFL), power meter,, optical return loss (ORL) and loss test sets (LTS). The T-BERD 6000 also has a, built-in optical talk set option for communicating and controlling remote units, along the fiber, and it can transfer data fast using the USB or Ethernet port.

Overview of Fiber Optic Applications
Compact and Highly Integrated
The versatility of the T-BERD 6000 allows it to address premises to long-haul, networks comprising new technologies, such as various fiber networks (FTTx),, remote optical add/drop multiplexers (ROADMs), and 40 G.

Built-in VFL, laser source power meter, LTS, talk set/data, and video inspection, scope options (simultaneously)
Bidirectional insertion loss (IL) and ORL capabilities combined in one module
OTDR and chromatic dispersion (CD) capabilities combined in one module
Polarization mode dispersion (PMD), wave division multiplexing (WDM), and, attenuation profile (AP) capabilities combined in one module
PMD, CD, and AP capabilities combined in one module

Wide Range of Test Applications
LAN/WAN Premises – 10 GigE local area network (LAN) qualification
Solution: T-BERD 6000 with the unique universal SRL 850/1300/1310/1550/1625 nm OTDR Module
FTTx/Access Networks – End-to-end connectivity on point-to-point networks, including sectionalized, testing on a passive optical network (PON) (without a splitter,
Solution: T-BERD 6000 with the VSRe, SRe,MR OTDR module at 1310/1550 nm
– End-to-end connectivity on PONs, including splitter qualification
Solution: T-BERD 6000 with the MR, LR, or VLR at 1310/1490/1550 nm OTDR, module
Add optional VFL, power meter, and video inspection scope
– In-service maintenance and troubleshooting without service disruption
Solution: T-BERD 6000 with the filtered LR OTDR module at 1625 nm
Metro/Core Networks – End-to-end connectivity and fiber splice qualification
Solution: T-BERD 6000 with the MR, LR, or VLR at 1310/1550/1625 nm OTDR module
Add optional VFL, power meter, and video inspection scope
Ultralong-Haul Networks – End-to-end connectivity and fiber splice qualification
Solution: T-BERD 6000 with the UHD OTDR m
10G/40G Fiber Characterization – Characterize fiber in high-speed transmission systems for loss/dispersion
Solution: T-BERD 6000 with the PMD/CD/AP, ODTR, and OFI module
CWDM/DWDM – Characterize fiber and prove suitability to carry multiple channels (water peak)
Solution: T-BERD 6000 with the VLR OTDR module at 1383 nm
Add the combined PMD/WDM/SA or CDWM OTDR module

Buying, Selling, Trading JDSU T-BERD 6000

Modular Platform – New technologies developed in the future
Solution: T-BERD 6000 with the new JDSU field-upgradeable application module
OTDR and IL/ORL Testing
A Wide Range of OTDR Modules
The JDSU OTDR plug-in module family provides a wide range of highperformance, OTDRs. Over 40 field-interchangeable modules are compatible with, the T-BERD 6000 for testing and troubleshooting any multimode or single-mode, network. The OTDR family includes six lines of OTDRs featuring:

New wavelengths to cover 1383 nm (CWDM) and 1490 nm (FTTx)
Highest dynamic range up to 50 dB
Shortest dead zones down to 0.5 m in multimode and 0.8 m in singlemode
Fastest scan speed at 0.1 s in real-time mode
From Simple Fault Locator to Expert OTDR…
The fault locator boosts productivity in the field by providing:

Fast detection
Precise fault location
One-button automation
No specific settings required
Distance, loss, and ORL measurements
The expert mode offers high-level trace analysis possibilities, making your, T-BERD 6000 platform a powerful instrument for commissioning and troubleshooting, by offering:

Manual settings (pulse, acquisition time, resolution, distance range)
Manual addition and deletion of events
Manual slopes, splices, and reflectances measurement
Ideal for End-to-End Commissioning
OTDR bidirectional testing is required to obtain true and accurate splice loss, readings. JDSU has developed an innovative automatic bidirectional analysis, function that is integrated directly into the T-BERD 6000 platform, saving at least, 50 percent of the time required for traditional bidirectional analysis.

Offers communication between two units via the link under test to set up the, same optimized acquisition parameters
Displays and saves automatic acquisitions in both directions on both units
Eliminates operator error
CWDM OTDR Modules
The CWDM OTDR module allows in-service OTDR measurements at, International Telecommunications Union (ITU-T) G.694.2 CWDM wavelengths.

This solution was developed to help network operators and dark fiber providers, characterize, maintain, and troubleshoot CWDM systems from short- to mediumhaul, fiber networks.

FTTx/PON In-Service Modules
To avoid interrupting customer traffic (in-service testing) of B/G/E-PON, networks the filtered OTDR module performs an out-of-band test using 1625 nm, wavelength.

Insertion Loss and Optical Return Loss Testing

Measures bidirectional IL, ORL, and fiber length
Offers one-button automated testing
Choose three wavelengths from 1310, 1490, 1550, and 1625 nm
Compatible with the OFI-2000 Multifunction Loss Test Set
CD,PMD,AP, and WDM Testing
The T-BERD 6000 enables CD and PMD measurements to identify fiber viability, for very high-speed transmission systems. It also enables WDM and AP tests to, validate the link compatibility with DWDM system implementation.

Polarization Mode Dispersion Testing

Fast and accurately measures PMD delay, PMD coefficient, and, second-order values
Offers high dynamic range (up to 65 dB) dedicated for metropolitan, long haul,, and very long haul fiber optic links
Offers shock- and vibration-proof design (with no moving parts)
Allows for measurement through multiple amplifiers
Provides statistics and long-term monitoring
Chromatic Dispersion Testing – OTDR-Based Method

Requires access to only one end of the fiber
Offers dynamic range (up to 120 km) dedicated for any metropolitan fiber optic, links
Includes acquisition points around 1310, 1480, 1550, and 1625 nm for accurate, CD from 1260 to 1650 nm
Integrates a four-wavelength OTDR and light source
Provides sectional analysis capability for troubleshooting
Offers shock- and vibration-proof design (with no moving parts)
Chromatic Dispersion Testing – Phase-Shift Method

Offers high dynamic range (up to 55 dB) dedicated for metropolitan, long haul,, and very long haul fiber optic links
Provides full wavelength range characterization (1260 to 1640 nm)
Allows for measurement through multiple amplifiers
Offers shock- and vibration-proof design (with no moving parts)
Attenuation Profile Testing

Provides total loss and dB/km values for full band testing (1260 to 1640 nm)
Allows CDWM and dense wavelength division multiplexing (DWDM), transmission band characterization
Provides water peak (1383 nm area) characterization
Offers shock- and vibration-proof design (with no moving parts)
Combined with WDM and PMD functions or with CD and PMD functions
DWDM Maintenance Testing

Measures channel level, power, and wavelength in the S, C, and L bands
Provides the most compact DWDM test solution that measures optical signalto-, noise ratio (OSNR)
Tests wavelengths from 1260 to 1640 nm or 1485 to 1640 nm
Offers high wavelength accuracy
Provides statistics and long-term monitoring
Offers shock- and vibration-proof design (with no moving parts)
Specifications
Specifications for Typical 25°C
Display
TFT color, 8.4 in LCD, 800 x 600, high-visibility (standard)
Touchscreen,TFT color, 8.4 in LCD, 800 x 600, high-visibility
(optional)
Storage and I/O Interfaces
Internal memory 1000 test results
Extended memory (optional) Minimum 1 GB (optional)
2x USB V1.1, 1x RJ45 Ethernet
Power Supply
Battery type Standard removable Li-ion batteries
AC/DC adapter Input 100–240 V, 50–60 Hz,
Output 19 V DC/3.1 A
Operation time Up to 11 hrs with standard display,
Telcordia GR-196-CORE
Size and Weight
Mainframe with one plug-in module
and battery (L x H x W) 285 x 195 x 93 mm
(11.2 x 7.7 x 3.7 in)
Mainframe only (without battery
and module) 2.4 kg (5.3 lb)
Mainframe (with one plug-in module
and battery) 3.4 kg (7.5 lb)
Environmental Specifications
Operating temperature range
on mains (no options) –20 to +50°C
(–4 to 122°F)
Operating temperature range (all
options) 0 to +40°C
(32 to 104°F)
Storage temperature range –20 to +60°C (–4 to 140°F)
Humidity, non-condensing 95%
Base Unit Optical Interfaces (optional)
Power Meter
Power level +10 to –60 dBm
Calibrated wavelengths 850, 1310, and 1550 nm
Connector type Universal push/pull (UPP
Talkset
Wavelength 1550 nm ±20 nm
Dynamic range 45 dB
Function With data/file transfer
Laser safety Class 1M laser
Connector type Field interchangeable
Optical Return Loss
Selectable wavelength 1310 / 1550 nm
Measurement range 0 dB to 45 dB
Measurement uncertainty ± 1 dB
Display resolution 0.01 dB
Visual Fault Locator
Wavelength 635 nm ±15 nm
Output power level <1 mW
Laser safety Class 2 laser
Connector type Universal push/pull (UPP)
Continuous Wave Light Source
Wavelengths (selection) 1310, 1550, and 1625 nm
Output power level –3.5 dBm
Stability in 15 min ± 0.02 dB
Stability in 8 hrs ± 0.2 dB
Laser safety Class 1M laser
Connector type Field interchangeable
Video Inspection Scope (via USB)
Magnification 250X and 400X, through the USB port
JDSU 8126 HD Single Mode Module

Central Wavelength 1310/1550nm +/- 20nm
Laser Safety Class Class 1
Pulse Width 10 ns To 20 µs
Distance Range Up to 380 km
RMS Dynamic Range 42db/40db
Event Dead Zone 3 m
Attenuation Dead Zone 15 m

If you’re selling your JDSU T-BERD 6000 please fill out form on the right hand side of page.

Selling JDSU MTS-6000 – We Buy New Used MTS-6000 (‘s) Top Dollar Paid!

If you’re looking to Sell JDSU MTS-6000 OTDR w/ 8126 SRe SM Fiber
JDSU MTS-6000 Compact Optical Test Platform Mainframe

Key Features:

Compact, lightweight, and highly integrated platform
More than 40 application modules already supported for, multimode and single-mode
Exceeds Telcordia specifications for ruggedness, drop, testing, and extended battery life
Compatible with plug-in modules from the MTS-51001, and T-BERD 8000

Applications

Performs multimode and, single-mode OTDR and optical loss, test (bidirectional)
Conducts connector inspection and, continuity testing
Finds faults and identifies traffic
Tests FTTx/PON and CWDM, networks
Performs fiber dispersion testing, (PMD/CD/AP) for 10G/10GE/40G
Allows for use of talk set/data port, for automated end-to-end, communication and unit control
Generates proof-of-performance, reports
The JDSU MTS-6000 is a highly integrated test platform designed for all, phases of the fiber network life cycle. It provides field service technicians with the, highest levels of performance and upgradeability on the market today.

The modular design of the MTS-6000 offers an extensive portfolio of test, functionality with over 40 different fiber modules supporting a wide range of, applications. The versatility of the MTS-6000 allows technicians to standardize, using one type of test equipment and then introduce new testing capabilities in, the field without incurring additional training or device costs.

The MTS-6000 is compatible with our existing fiber module product line, so, technicians can exchange plug-in modules between the T-BERD-8000 Scalable, Optical Test Platform and the MTS-6000 , in the field and without the need for, additional tools. To ensure the highest level of return on your capital investment, for test equipment, an extension allows you to upgrade existing OTDR modules, from the MTS-5100 for use with the MTS-6000 .

To ensure the highest-level return on investment for your test equipment, upgrade, existing optical time domain reflectometer (OTDR) modules from the MTS-5100, (with an extension) for use with the MTS-6000 .
Ideal for Field Testing

The MTS-6000 is a highly integrated platform with a single module slot and, the option to extend internal memory up to 1 gigabyte. The platform features an, intuitive graphical user interface (GUI) shown on a large 8.4 inch transreflective, color display (with an optional touchscreen) to improve viewing under any, condition. The high capacity Lithium ion battery adds extended life.

OTDR and IL/ORL Testing
A Wide Range of OTDR Modules
The JDSU OTDR plug-in module family provides a wide range of highperformance, OTDRs. Over 40 field-interchangeable modules are compatible with, the MTS-6000 for testing and troubleshooting any multimode or single-mode, network. The OTDR family includes six lines of OTDRs featuring:

New wavelengths to cover 1383 nm (CWDM) and 1490 nm (FTTx)
Highest dynamic range up to 50 dB
Shortest dead zones down to 0.5 m in multimode and 0.8 m in singlemode
Fastest scan speed at 0.1 s in real-time mode

From Simple Fault Locator to Expert OTDR…
The fault locator boosts productivity in the field by providing:

Fast detection
Precise fault location
One-button automation
No specific settings required
Distance, loss, and ORL measurements
The expert mode offers high-level trace analysis possibilities, making your, MTS-6000 platform a powerful instrument for commissioning and troubleshooting, by offering:

Manual settings (pulse, acquisition time, resolution, distance range)
Manual addition and deletion of events
Manual slopes, splices, and reflectances measurement

Ideal for End-to-End Commissioning
OTDR bidirectional testing is required to obtain true and accurate splice loss, readings. JDSU has developed an innovative automatic bidirectional analysis, function that is integrated directly into the MTS-6000 platform, saving at least, 50 percent of the time required for traditional bidirectional analysis.

Offers communication between two units via the link under test to set up the, same optimized acquisition parameters
Displays and saves automatic acquisitions in both directions on both units
Eliminates operator error
This solution was developed to help network operators and dark fiber providers, characterize, maintain, and troubleshoot CWDM systems from short- to mediumhaul, fiber networks.

Buying, Selling, Trading JDSU MTS-6000
Insertion Loss and Optical Return Loss Testing

Measures bidirectional IL, ORL, and fiber length
Offers one-button automated testing
Compatible with the OFI-2000 Multifunction Loss Test Set
Specifications
Specifications for Typical 25°C
Display
TFT color, 8.4 in LCD, 800 x 600, high-visibility (standard)
Touchscreen,TFT color, 8.4 in LCD, 800 x 600, high-visibility
(optional)
Storage and I/O Interfaces
Internal memory 1000 test results
Extended memory (optional) Minimum 1 GB (optional)
2x USB V1.1, 1x RJ45 Ethernet
Power Supply
Battery type Standard removable Li-ion batteries
AC/DC adapter Input 100–240 V, 50–60 Hz,
Output 19 V DC/3.1 A
Operation time Up to 11 hrs with standard display,
Telcordia GR-196-CORE
Size and Weight
Mainframe with one plug-in module
and battery (L x H x W) 285 x 195 x 93 mm
(11.2 x 7.7 x 3.7 in)
Mainframe only (without battery
and module) 2.4 kg (5.3 lb)
Mainframe (with one plug-in module
and battery) 3.4 kg (7.5 lb)
Environmental Specifications
Operating temperature range
on mains (no options) –20 to +50°C
(–4 to 122°F)
Operating temperature range (all
options) 0 to +40°C
(32 to 104°F)
Storage temperature range –20 to +60°C (–4 to 140°F)
Humidity, non-condensing 95%
Base Unit Optical Interfaces (optional)
Power Meter
Power level +10 to –60 dBm
Calibrated wavelengths 850, 1310, and 1550 nm
Connector type Universal push/pull (UPP
Talkset
Wavelength 1550 nm ±20 nm
Dynamic range 45 dB
Function With data/file transfer
Laser safety Class 1M laser
Connector type Field interchangeable
Optical Return Loss
Selectable wavelength 1310 / 1550 nm
Measurement range 0 dB to 45 dB
Measurement uncertainty ± 1 dB
Display resolution 0.01 dB
Visual Fault Locator
Wavelength 635 nm ±15 nm
Output power level <1 mW
Laser safety Class 2 laser
Connector type Universal push/pull (UPP)
Continuous Wave Light Source
Wavelengths (selection) 1310, 1550, and 1625 nm
Output power level –3.5 dBm
Stability in 15 min ± 0.02 dB
Stability in 8 hrs ± 0.2 dB
Laser safety Class 1M laser
Connector type Field interchangeable
Video Inspection Scope (via USB)
Magnification 250X and 400X, through the USB port
JDSU 8126 SRE Single Mode Module
Central Wavelength 1310/1550nm +/- 20nm
Laser Safety Class Class 1
Pulse Width 10 ns To 10 µs
Distance Range Up to 260 km
RMS Dynamic Range 34db/32db
Event Dead Zone 3 m
Attenuation Dead Zone 15 m

If you’re selling your JDSU MTS-6000 please fill out form on the right hand side of page.

Selling JDSU T-BERD 6000 – We Buy New Used 6000 (‘s) Top Dollar Paid!

If you’re looking to Sell JDSU T-BERD 6000 OTDR w/ 8126 VSRe SM Fiber Module

JDSU T-BERD 6000 Compact Optical Test Platform Mainframe

Key Features:

Compact, lightweight, and highly integrated platform
More than 40 application modules already supported for, multimode and single-mode
Built-in VFL, power meter, LTS, ORL, and video inspection, scope options
Choose from IL/ORL,OTDR,PMD,CD, AP and/or WDM, plug-ins
Exceeds Telcordia specifications for ruggedness, drop, testing, and extended battery life
Compatible with plug-in modules from the MTS-51001, and T-BERD 8000
Applications

Performs multimode and, single-mode OTDR and optical loss, test (bidirectional)
Conducts connector inspection and, continuity testing
Finds faults and identifies traffic
Tests FTTx/PON and CWDM, networks
Performs fiber dispersion testing, (PMD/CD/AP) for 10G/10GE/40G
Allows for use of talk set/data port, for automated end-to-end, communication and unit control
Generates proof-of-performance, reports
The JDSU T-BERD 6000 is a highly integrated test platform designed for all, phases of the fiber network life cycle. It provides field service technicians with the, highest levels of performance and upgradeability on the market today.

The modular design of the T-BERD 6000 offers an extensive portfolio of test, functionality with over 40 different fiber modules supporting a wide range of, applications. The versatility of the T-BERD 6000 allows technicians to standardize, using one type of test equipment and then introduce new testing capabilities in, the field without incurring additional training or device costs.

The T-BERD 6000 is compatible with our existing fiber module product line, so, technicians can exchange plug-in modules between the T-BERD-8000 Scalable, Optical Test Platform and the T-BERD 6000, in the field and without the need for, additional tools. To ensure the highest level of return on your capital investment, for test equipment, an extension allows you to upgrade existing OTDR modules, from the MTS-5100 for use with the T-BERD 6000.

To ensure the highest-level return on investment for your test equipment, upgrade, existing optical time domain reflectometer (OTDR) modules from the MTS-5100, (with an extension) for use with the T-BERD 6000.

Ideal for Field Testing

The T-BERD 6000 is a highly integrated platform with a single module slot and, the option to extend internal memory up to 1 gigabyte. The platform features an, intuitive graphical user interface (GUI) shown on a large 8.4 inch transreflective, color display (with an optional touchscreen) to improve viewing under any, condition. The high capacity Lithium ion battery adds extended life. Other, features include an optional video inspection scope (via USB port), and optional, built-in optical test functions, such as a visual fault locator (VFL), power meter,, optical return loss (ORL) and loss test sets (LTS). The T-BERD 6000 also has a, built-in optical talk set option for communicating and controlling remote units, along the fiber, and it can transfer data fast using the USB or Ethernet port.

Overview of Fiber Optic Applications
Compact and Highly Integrated
The versatility of the T-BERD 6000 allows it to address premises to long-haul, networks comprising new technologies, such as various fiber networks (FTTx),, remote optical add/drop multiplexers (ROADMs), and 40 G.

Built-in VFL, laser source power meter, LTS, talk set/data, and video inspection, scope options (simultaneously)
Bidirectional insertion loss (IL) and ORL capabilities combined in one module
OTDR and chromatic dispersion (CD) capabilities combined in one module
Polarization mode dispersion (PMD), wave division multiplexing (WDM), and, attenuation profile (AP) capabilities combined in one module
PMD, CD, and AP capabilities combined in one module

Wide Range of Test Applications
LAN/WAN Premises – 10 GigE local area network (LAN) qualification
Solution: T-BERD 6000 with the unique universal SRL 850/1300/1310/1550/1625 nm OTDR Module
FTTx/Access Networks – End-to-end connectivity on point-to-point networks, including sectionalized, testing on a passive optical network (PON) (without a splitter,
Solution: T-BERD 6000 with the VSRe, SRe,MR OTDR module at 1310/1550 nm
– End-to-end connectivity on PONs, including splitter qualification
Solution: T-BERD 6000 with the MR, LR, or VLR at 1310/1490/1550 nm OTDR, module
Add optional VFL, power meter, and video inspection scope
– In-service maintenance and troubleshooting without service disruption
Solution: T-BERD 6000 with the filtered LR OTDR module at 1625 nm
Metro/Core Networks – End-to-end connectivity and fiber splice qualification
Solution: T-BERD 6000 with the MR, LR, or VLR at 1310/1550/1625 nm OTDR module
Add optional VFL, power meter, and video inspection scope
Ultralong-Haul Networks – End-to-end connectivity and fiber splice qualification
Solution: T-BERD 6000 with the UHD OTDR m
10G/40G Fiber Characterization – Characterize fiber in high-speed transmission systems for loss/dispersion
Solution: T-BERD 6000 with the PMD/CD/AP, ODTR, and OFI module
CWDM/DWDM – Characterize fiber and prove suitability to carry multiple channels (water peak)
Solution: T-BERD 6000 with the VLR OTDR module at 1383 nm
Add the combined PMD/WDM/SA or CDWM OTDR module

Buying, Selling, Trading JDSU T-BERD 6000

Modular Platform – New technologies developed in the future
Solution: T-BERD 6000 with the new JDSU field-upgradeable application module
OTDR and IL/ORL Testing
A Wide Range of OTDR Modules
The JDSU OTDR plug-in module family provides a wide range of highperformance, OTDRs. Over 40 field-interchangeable modules are compatible with, the T-BERD 6000 for testing and troubleshooting any multimode or single-mode, network. The OTDR family includes six lines of OTDRs featuring:

New wavelengths to cover 1383 nm (CWDM) and 1490 nm (FTTx)
Highest dynamic range up to 50 dB
Shortest dead zones down to 0.5 m in multimode and 0.8 m in singlemode
Fastest scan speed at 0.1 s in real-time mode
From Simple Fault Locator to Expert OTDR…
The fault locator boosts productivity in the field by providing:

Fast detection
Precise fault location
One-button automation
No specific settings required
Distance, loss, and ORL measurements
The expert mode offers high-level trace analysis possibilities, making your, T-BERD 6000 platform a powerful instrument for commissioning and troubleshooting, by offering:

Manual settings (pulse, acquisition time, resolution, distance range)
Manual addition and deletion of events
Manual slopes, splices, and reflectances measurement
Ideal for End-to-End Commissioning
OTDR bidirectional testing is required to obtain true and accurate splice loss, readings. JDSU has developed an innovative automatic bidirectional analysis, function that is integrated directly into the T-BERD 6000 platform, saving at least, 50 percent of the time required for traditional bidirectional analysis.

Offers communication between two units via the link under test to set up the, same optimized acquisition parameters
Displays and saves automatic acquisitions in both directions on both units
Eliminates operator error
CWDM OTDR Modules
The CWDM OTDR module allows in-service OTDR measurements at, International Telecommunications Union (ITU-T) G.694.2 CWDM wavelengths.

This solution was developed to help network operators and dark fiber providers, characterize, maintain, and troubleshoot CWDM systems from short- to mediumhaul, fiber networks.

FTTx/PON In-Service Modules
To avoid interrupting customer traffic (in-service testing) of B/G/E-PON, networks the filtered OTDR module performs an out-of-band test using 1625 nm, wavelength.

Insertion Loss and Optical Return Loss Testing

Measures bidirectional IL, ORL, and fiber length
Offers one-button automated testing
Choose three wavelengths from 1310, 1490, 1550, and 1625 nm
Compatible with the OFI-2000 Multifunction Loss Test Set
CD,PMD,AP, and WDM Testing
The T-BERD 6000 enables CD and PMD measurements to identify fiber viability, for very high-speed transmission systems. It also enables WDM and AP tests to, validate the link compatibility with DWDM system implementation.

Polarization Mode Dispersion Testing

Fast and accurately measures PMD delay, PMD coefficient, and, second-order values
Offers high dynamic range (up to 65 dB) dedicated for metropolitan, long haul,, and very long haul fiber optic links
Offers shock- and vibration-proof design (with no moving parts)
Allows for measurement through multiple amplifiers
Provides statistics and long-term monitoring
Chromatic Dispersion Testing – OTDR-Based Method

Requires access to only one end of the fiber
Offers dynamic range (up to 120 km) dedicated for any metropolitan fiber optic, links
Includes acquisition points around 1310, 1480, 1550, and 1625 nm for accurate, CD from 1260 to 1650 nm
Integrates a four-wavelength OTDR and light source
Provides sectional analysis capability for troubleshooting
Offers shock- and vibration-proof design (with no moving parts)
Chromatic Dispersion Testing – Phase-Shift Method

Offers high dynamic range (up to 55 dB) dedicated for metropolitan, long haul,, and very long haul fiber optic links
Provides full wavelength range characterization (1260 to 1640 nm)
Allows for measurement through multiple amplifiers
Offers shock- and vibration-proof design (with no moving parts)
Attenuation Profile Testing

Provides total loss and dB/km values for full band testing (1260 to 1640 nm)
Allows CDWM and dense wavelength division multiplexing (DWDM), transmission band characterization
Provides water peak (1383 nm area) characterization
Offers shock- and vibration-proof design (with no moving parts)
Combined with WDM and PMD functions or with CD and PMD functions
DWDM Maintenance Testing

Measures channel level, power, and wavelength in the S, C, and L bands
Provides the most compact DWDM test solution that measures optical signalto-, noise ratio (OSNR)
Tests wavelengths from 1260 to 1640 nm or 1485 to 1640 nm
Offers high wavelength accuracy
Provides statistics and long-term monitoring
Offers shock- and vibration-proof design (with no moving parts)
Specifications
Specifications for Typical 25°C
Display
TFT color, 8.4 in LCD, 800 x 600, high-visibility (standard)
Touchscreen,TFT color, 8.4 in LCD, 800 x 600, high-visibility
(optional)
Storage and I/O Interfaces
Internal memory 1000 test results
Extended memory (optional) Minimum 1 GB (optional)
2x USB V1.1, 1x RJ45 Ethernet
Power Supply
Battery type Standard removable Li-ion batteries
AC/DC adapter Input 100–240 V, 50–60 Hz,
Output 19 V DC/3.1 A
Operation time Up to 11 hrs with standard display,
Telcordia GR-196-CORE
Size and Weight
Mainframe with one plug-in module
and battery (L x H x W) 285 x 195 x 93 mm
(11.2 x 7.7 x 3.7 in)
Mainframe only (without battery
and module) 2.4 kg (5.3 lb)
Mainframe (with one plug-in module
and battery) 3.4 kg (7.5 lb)
Environmental Specifications
Operating temperature range
on mains (no options) –20 to +50°C
(–4 to 122°F)
Operating temperature range (all
options) 0 to +40°C
(32 to 104°F)
Storage temperature range –20 to +60°C (–4 to 140°F)
Humidity, non-condensing 95%
Base Unit Optical Interfaces (optional)
Power Meter
Power level +10 to –60 dBm
Calibrated wavelengths 850, 1310, and 1550 nm
Connector type Universal push/pull (UPP
Talkset
Wavelength 1550 nm ±20 nm
Dynamic range 45 dB
Function With data/file transfer
Laser safety Class 1M laser
Connector type Field interchangeable
Optical Return Loss
Selectable wavelength 1310 / 1550 nm
Measurement range 0 dB to 45 dB
Measurement uncertainty ± 1 dB
Display resolution 0.01 dB
Visual Fault Locator
Wavelength 635 nm ±15 nm
Output power level <1 mW
Laser safety Class 2 laser
Connector type Universal push/pull (UPP)
Continuous Wave Light Source
Wavelengths (selection) 1310, 1550, and 1625 nm
Output power level –3.5 dBm
Stability in 15 min ± 0.02 dB
Stability in 8 hrs ± 0.2 dB
Laser safety Class 1M laser
Connector type Field interchangeable
Video Inspection Scope (via USB)
Magnification 250X and 400X, through the USB port

8126 VSR Singlemode OTDR Module
The new JDSU Very Short Range (VSR) OTDR Module for the MTS/T-Berd 8000 and MTS/T-Berd 6000 product platforms provides the needed performance with maximum efficiency for any access/FTTx/Metro network test application.

In the telecommunication market of today, OTDR est solutions must be cost-effective, easy-to-operate and flexible for optimum use in all testing conditions.

The MTS/T-Berd product line has built a solid worldwide reputation based on cutting-edge design and performance. Compatibility with thousands of field-proven units deployed worldwide by every major telecommunications network operator enables easy migration to new network technologies while continuing to reduce expenses.

Fast and precise fault location
Fast detection
Precise fault location
One button automation
No specific setting required
Distance, loss, and ORL measurements
Ideal for construction and maintenance
Fully automatic or manual modes
Templates for multi fiber acquisitions
Automatic, semi-automatic, or manual measurments
Multitrace display for trace comparison
Auto filenaming and auto storage with comprehensive cable and fiber identification
Macrobend detection
Specifications

Typical specifications at 25°C
Optical interfaces
Applicable fiber SMF 9/125 µm
Interchangeable optical connectors FC, SC, DIN, ST, LC
Physical
Weight 600g (1.1lbs)
Size 213 x 124 x 32 mm
(8.38 x 4.88 x 1.26 in)
OTDR Optical performance
Central wavelength 1310/1550 nm
±20 nm
Laser safety class (21 CFR) Class 1M
Pulsewidth 10 ns to 10µs ns
Distance range Up to 200 km
RMS Dynamic Range 32dB / 30dB
Event dead zone 2m
Attenuation dead zone 8m
Technical characteristics
Distance units Kilometers, feet, and miles
Group index range 1.30000 to 1.70000 in
0.00001 steps
Number of data points Up to 128,000 data points
Distance measurement Automatic or dual cursor
Display span 2.6 m to 200 km
Cursor resolution 1 cm
Sampling resolution 4 cm
Accuracy ±1 m ±sampling resolution ±1.10-5 x distance
(Excluding group index uncertainties)
Attenuation measurement
Automatic, manual, 2-point, 5-point, and LSA
Display span 1.25 dB to 55 dB
Display resolution 0.001 dB
Cursor resolution 0.001 dB
Linearity ±0.03 dB/dB
Threshold 0.01 to 5.99 dB in 0.01 dB steps
Reflectance/ORL measurements
Automatic or manual
Uncertainty +/-2dB
Display resolution 0.01 dB
Threshold -11 dB to -99 dB in 1 dB steps
Storage

Bellcore/Telcordia compatible
Version1.1 and Version 2.0

If you’re selling your JDSU T-BERD 6000 please fill out form on the right hand side of page.