Current post: Selling JDSU MTS-6000 – We Buy New Used MTS-6000 (‘s) Top Dollar Paid!

Selling JDSU MTS-6000 – We Buy New Used MTS-6000 (‘s) Top Dollar Paid!

If you’re looking to Sell JDSU MTS-6000 OTDR w/ 8126 SRe SM Fiber
JDSU MTS-6000 Compact Optical Test Platform Mainframe

Key Features:

Compact, lightweight, and highly integrated platform
More than 40 application modules already supported for, multimode and single-mode
Exceeds Telcordia specifications for ruggedness, drop, testing, and extended battery life
Compatible with plug-in modules from the MTS-51001, and T-BERD 8000

Applications

Performs multimode and, single-mode OTDR and optical loss, test (bidirectional)
Conducts connector inspection and, continuity testing
Finds faults and identifies traffic
Tests FTTx/PON and CWDM, networks
Performs fiber dispersion testing, (PMD/CD/AP) for 10G/10GE/40G
Allows for use of talk set/data port, for automated end-to-end, communication and unit control
Generates proof-of-performance, reports
The JDSU MTS-6000 is a highly integrated test platform designed for all, phases of the fiber network life cycle. It provides field service technicians with the, highest levels of performance and upgradeability on the market today.

The modular design of the MTS-6000 offers an extensive portfolio of test, functionality with over 40 different fiber modules supporting a wide range of, applications. The versatility of the MTS-6000 allows technicians to standardize, using one type of test equipment and then introduce new testing capabilities in, the field without incurring additional training or device costs.

The MTS-6000 is compatible with our existing fiber module product line, so, technicians can exchange plug-in modules between the T-BERD-8000 Scalable, Optical Test Platform and the MTS-6000 , in the field and without the need for, additional tools. To ensure the highest level of return on your capital investment, for test equipment, an extension allows you to upgrade existing OTDR modules, from the MTS-5100 for use with the MTS-6000 .

To ensure the highest-level return on investment for your test equipment, upgrade, existing optical time domain reflectometer (OTDR) modules from the MTS-5100, (with an extension) for use with the MTS-6000 .
Ideal for Field Testing

The MTS-6000 is a highly integrated platform with a single module slot and, the option to extend internal memory up to 1 gigabyte. The platform features an, intuitive graphical user interface (GUI) shown on a large 8.4 inch transreflective, color display (with an optional touchscreen) to improve viewing under any, condition. The high capacity Lithium ion battery adds extended life.

OTDR and IL/ORL Testing
A Wide Range of OTDR Modules
The JDSU OTDR plug-in module family provides a wide range of highperformance, OTDRs. Over 40 field-interchangeable modules are compatible with, the MTS-6000 for testing and troubleshooting any multimode or single-mode, network. The OTDR family includes six lines of OTDRs featuring:

New wavelengths to cover 1383 nm (CWDM) and 1490 nm (FTTx)
Highest dynamic range up to 50 dB
Shortest dead zones down to 0.5 m in multimode and 0.8 m in singlemode
Fastest scan speed at 0.1 s in real-time mode

From Simple Fault Locator to Expert OTDR…
The fault locator boosts productivity in the field by providing:

Fast detection
Precise fault location
One-button automation
No specific settings required
Distance, loss, and ORL measurements
The expert mode offers high-level trace analysis possibilities, making your, MTS-6000 platform a powerful instrument for commissioning and troubleshooting, by offering:

Manual settings (pulse, acquisition time, resolution, distance range)
Manual addition and deletion of events
Manual slopes, splices, and reflectances measurement

Ideal for End-to-End Commissioning
OTDR bidirectional testing is required to obtain true and accurate splice loss, readings. JDSU has developed an innovative automatic bidirectional analysis, function that is integrated directly into the MTS-6000 platform, saving at least, 50 percent of the time required for traditional bidirectional analysis.

Offers communication between two units via the link under test to set up the, same optimized acquisition parameters
Displays and saves automatic acquisitions in both directions on both units
Eliminates operator error
This solution was developed to help network operators and dark fiber providers, characterize, maintain, and troubleshoot CWDM systems from short- to mediumhaul, fiber networks.

Buying, Selling, Trading JDSU MTS-6000
Insertion Loss and Optical Return Loss Testing

Measures bidirectional IL, ORL, and fiber length
Offers one-button automated testing
Compatible with the OFI-2000 Multifunction Loss Test Set
Specifications
Specifications for Typical 25°C
Display
TFT color, 8.4 in LCD, 800 x 600, high-visibility (standard)
Touchscreen,TFT color, 8.4 in LCD, 800 x 600, high-visibility
(optional)
Storage and I/O Interfaces
Internal memory 1000 test results
Extended memory (optional) Minimum 1 GB (optional)
2x USB V1.1, 1x RJ45 Ethernet
Power Supply
Battery type Standard removable Li-ion batteries
AC/DC adapter Input 100–240 V, 50–60 Hz,
Output 19 V DC/3.1 A
Operation time Up to 11 hrs with standard display,
Telcordia GR-196-CORE
Size and Weight
Mainframe with one plug-in module
and battery (L x H x W) 285 x 195 x 93 mm
(11.2 x 7.7 x 3.7 in)
Mainframe only (without battery
and module) 2.4 kg (5.3 lb)
Mainframe (with one plug-in module
and battery) 3.4 kg (7.5 lb)
Environmental Specifications
Operating temperature range
on mains (no options) –20 to +50°C
(–4 to 122°F)
Operating temperature range (all
options) 0 to +40°C
(32 to 104°F)
Storage temperature range –20 to +60°C (–4 to 140°F)
Humidity, non-condensing 95%
Base Unit Optical Interfaces (optional)
Power Meter
Power level +10 to –60 dBm
Calibrated wavelengths 850, 1310, and 1550 nm
Connector type Universal push/pull (UPP
Talkset
Wavelength 1550 nm ±20 nm
Dynamic range 45 dB
Function With data/file transfer
Laser safety Class 1M laser
Connector type Field interchangeable
Optical Return Loss
Selectable wavelength 1310 / 1550 nm
Measurement range 0 dB to 45 dB
Measurement uncertainty ± 1 dB
Display resolution 0.01 dB
Visual Fault Locator
Wavelength 635 nm ±15 nm
Output power level <1 mW
Laser safety Class 2 laser
Connector type Universal push/pull (UPP)
Continuous Wave Light Source
Wavelengths (selection) 1310, 1550, and 1625 nm
Output power level –3.5 dBm
Stability in 15 min ± 0.02 dB
Stability in 8 hrs ± 0.2 dB
Laser safety Class 1M laser
Connector type Field interchangeable
Video Inspection Scope (via USB)
Magnification 250X and 400X, through the USB port
JDSU 8126 SRE Single Mode Module
Central Wavelength 1310/1550nm +/- 20nm
Laser Safety Class Class 1
Pulse Width 10 ns To 10 µs
Distance Range Up to 260 km
RMS Dynamic Range 34db/32db
Event Dead Zone 3 m
Attenuation Dead Zone 15 m

If you’re selling your JDSU MTS-6000 please fill out form on the right hand side of page.