Selling Fluke DTX-QUAD – We Buy New Used DTX-QUAD (‘s) Top Dollar Paid!

If you’re looking to Sell Fluke DTX-QUAD OTDR SM MM Fiber OTDR DTX-1800

Fluke Networks DTX-1800 Digital Cable Analyzer

The DTX CableAnalyzer™ Series from Fluke Networks is the testing platform for today and tomorrow. This revolutionary platform significantly reduces total time to certify by improving every aspect of the testing process. It all starts with a Cat 6 Autotest time that’s several times faster than other testers and fiber testing that’s five times faster. DTX also gives you a complete solution for 10 Gig testing over copper, Basic Tier 1 fiber testing, and Extended Tier 2 fiber testing with the industry’s only modular OTDR. The DTX makes you ready for whatever the world throws at you – today and tomorrow.

Significantly reduces total time to certify.

The DTX Digital CableAnalyzer Series gives you a complete solution that streamlines every aspect of the certification job from setup, to record fast testing and troubleshooting, to reporting results to the customer. All told, DTX can save you considerable time and money up to four hours a day.

Cat 6 certification in 9 seconds

The DTX-1200 and DTX-1800 perform Cat 6 certification tests in just 9 seconds in full compliance with industry standards and with superior accuracy. That’s several times faster than existing testers. This incredible speed means you can test up to 170 more links in an eight-hour shift.

Troubleshoot faults twice as fast

When a link fails, the DTX Series provides quick, easy-to-understand directions to identify the point of failure (distance from the tester) and the possible reason(s) for the failure.

These directions not only tell you the problem, but also identify corrective actions your test technicians can take to solve the problem quickly all without having to consult the project manager. Instead of spending time executing trial and error corrections – and re-testing to find out whether the problem has been resolved the technician knows exactly where to look and what to do to fix the failing link. Even if only two percent of the cables certified in one shift fail Autotest, you’ll save as much as two hours of labor time per day of certifying.

Fast even when you’re not testing

The DTX Series isn’t just a faster way to test. It cuts setup and reporting times. Its ease-of-use lowers training time. Extended battery life means you can do more on a single charge. And a bright color display, ample memory, and built-in talk set all contribute to overall productivity while enhancing the user experience. This all adds up to save you time and money every day.

Enhance the power of DTX, Verify network service availability

Improve the services you offer your customers with the DTX CableAnalyzer and Network Service Module (DTX-NSM). Simply plug the DTX-NSM module into the back of the main unit and you’re ready to verify network service availability and link connectivity up to 1 Gigabit Ethernet. Verify if a link is active, identify its data rate, duplex capabilities and whether power is available for PoE. Then document all the network connectivity tests executed as an integrated part of the cable certification documentation provided by LinkWare.

Test cabling with Midspan PSEs for POE applications

Midspan power sources block DC power from traveling to the Ethernet switch or other active equipment in the wiring closet. This prohibits Wiremap tests of the link with conventional DC test methods. The DTX Series CableAnalyzer has the capability to test cabling using AC signals. This unique feature allows full certification to ISO and TIA standards where Midspan Power over Ethernet supplies are used.

Certify patch cord performance

Test patch cords to ensure optimal network performance with greater channel throughput and greater system margin. Attach the optional DTX Patch Cord Adapters (DTX-PCU6S) to the DTX main and remote units and you’re ready to certify patch cord performance to TIA Cat 6/5e specifications and also ISO class D/E.

Test coaxial cable quickly and easily

Extend the capabilities of your DTX CableAnalyzer to test coaxial cabling systems including legacy data cabling (such as 10BASE-2 or 10BASE-5 Ethernet) and video distribution coaxial cabling. Test coax cable length, propagation delay, cable (input) impedance and insertion loss as a function of signal frequency.

Buying, Selling, Trading Fluke DTX-QUAD

Fluke DTX-OTDR Module

The DTX Compact OTDR is a full featured Optical Time Domain Reflectometer (OTDR) module that snaps onto the Fluke Networks DTX CableAnalyzer. It makes the DTX powerful certification tool a complete, easy-to-use OTDR that shoots and analyzes traces on singlemode and multimode fiber.

The DTX Compact OTDR module makes every technician a fiber expert with unparalleled ease of use, automatic OTDR settings, loss limits for events and fiber links, launch fiber compensation, automatic event analysis, and results management – all with the familiar user interface of the DTX CableAnalyzer.

The DTX Compact OTDR Module leverages a contractor’s investment in the DTX CableAnalyzer by:

  • Expanding installation revenue without expanding staff
  • Shortening the technicians’ learning curve for fiber testing
  • Performing Basic (Tier 1) and Extended (Tier 2) fiber certification with a single tool
  • Accelerating troubleshooting with a powerful, single-ended OTDR
  • Delivering integrated copper and fiber reports using LinkWare™
  • Results Management Software

If you’re selling your Fluke DTX-QUAD please fill out form on the right hand side of page.

Selling Fluke Networks OF-500 – We Buy New Used OF-500 (‘s) Top Dollar Paid!

If you’re looking to Sell Fluke Networks OF-500 OptiFiber MM Fiber OTDR

Features

  • Tier 2 Fiber Certification
  • Powerful Diagnostics
  • Auto OTDR Analysis
  • Loss Length Certification
  • Fiber End-face Inspection
  • ChannelMap View
  • Power Meter
  • Results Management
  • Easy-to-use Interface
  • OTDR Port Check
  • Multiple Languages
  • Modularity and Portability

 

With OptiFiber, network engineers have in-house capability to:

  • Perform inspection, verification, certification, troubleshooting, and documentation of fiber cabling in a single, easy tool
  • Save time and money when diagnosing fiber cabling problems that are causing network performance issues
  • Easily locate and eliminate fiber problems
  • Check the work of subcontractors

ChannelMap™
Troubleshooting starts here. See a diagram of the channel, including patch cords. Check that the links are patched all the way across the campus, and determine the number and location of all connectors in a channel.
OTDR
View the trace of the fiber link. Compare one fiber to another by using Trace Overlay. Zoom in for a closer look at events. Move quickly to areas of interest. Identify suspect optical events such as high-loss connections.
Event Table
OptiFiber’s event table analysis automatically characterizes and compares loss and reflectance against user defined limits. Results are displayed in an easy-to-read table which makes it simple for you to present to your customers.
Loss/Length Certification
PASS/FAIL Optical loss analysis makes it easy to certify that the fiber meets applicable industry standard requirements – and presents the data in a clear, easy-to-interpret format.
FiberInspector™ Pro
The fiber inspection video probe provides a high-resolution 250X/400X end-face image of a fiber connector. Grade the image. Save the image – and show it to your customer.
OTDR Port Quality Check
OptiFiber incorporates an automated port quality check that warns the user when the OTDR port is dirty or contaminated.

Description

As bandwidth increases to more than 10 Gb/s, the use of fiber optics in premise networks continues to grow- and so do the requirements for testing and certifying it. To ensure the performance of mission-critical fiber infrastructure, network owners need a more complete picture of their fiber plant. And no solution provides a more complete picture than OptiFiber.

OptiFiber integrates power/loss, fiber length measurement, OTDR analysis and fiber connector end-face imaging to provide a higher tier of fiber certification and diagnostics. The companion LinkWare PC software documents, reports and manages all test data.

OptiFiber enables network owners of all experience levels to certify fiber to customer specifications and new industry standards, troubleshoot connection-rich links, and thoroughly document results. It will improve the health of your fiber network. Your fiber cabling will be ready and capable to perform for high-bandwidth applications.

Buying, Selling, Trading Fluke Networks OF-500

Tier 2 Fiber Certification

Applications such as 10 Gb/s Ethernet require lower losses and higher quality installations. OptiFiber advances the testing of premise fiber optic cabling, providing all the individual tests and documentation required to ensure the cable plant was correctly installed in accordance with best professional practices and new standards.

The TIA TSB-140 includes two tiers of testing that can be chosen by a designer to be specified in a project. Tier 1 accommodates loss and length testing with an optical loss test set (OLTS). Tier 2 testing includes the parameters of Tier 1 and also an OTDR trace of the installed cable plant. By incorporating the proposed two-tier testing method, installers have the most complete picture of the fiber installation and network owners have proof of a quality installation. Recent IEC standards also include the recommendation of a second level of testing.

OptiFiber delivers on Tier 2 certification by integrating bi-directional two-fiber dual-wavelength insertion loss and automated OTDR pass/fail link analysis a one-two combination you will find only with OptiFiber. But OptiFiber doesn’t stop there. It also offers fiber endface grading. Only with OptiFiber can you certify every link with one tool by:

  • measuring loss and length
  • analyzing the OTDR trace
  • grading the connector end-face

Then use the companion LinkWare cable test management software to present this test data in a single certification report that can be archived or submitted as proof of a properly installed and terminated installation.

Powerful Diagnostics

OptiFiber integrates the features that matter most when troubleshooting enterprise networks. These networks are characterized by relatively short lengths of fiber within data centers or between buildings. Fibers are terminated with connectors and segments connected with short patch cables. No other OTDR let’s you see both ends of short patch cables, allowing you to see the condition of your connectors so you can quickly and efficiently diagnose and fix the problem.

OptiFiber leads the industry with:

  • event characterization analysis
  • advanced multimode modules with event deadzone of .5 meter at 850nm
  • advanced singlemode modules with event deadzones of 1 meter at 1310/1550 nm
  • a unique map of the channel that illustrates the location of all connectors
  • automated OTDR trace and event test limits
  • 250x and 400x high magnification video end-face inspection

Document the condition of your network with LinkWare Cable Test Management software.

Auto OTDR Analysis

OptiFiber simplifies OTDR analysis by automating certification and troubleshooting. In Auto OTDR mode OptiFiber automatically:

  • optimizes launch conditions for the best resolution
  • makes dual wavelength OTDR measurements – 850/1300 nm or 1310/1550 nm
  • identifies and characterizes the fiber link and its events
  • compares the results to user-defined limits for immediate pass/fail link and event certification
  • saves time spent setting and moving cursors

For advanced troubleshooting you can view a trace at two wavelengths. Automatically step from one event to the next and zoom in on those of interest. Measure event loss. Events are also summarized in a table. Save the information for LinkWare reporting.

You may also choose to operate OptiFiber in manual mode so you can set the test parameters yourself.

Loss/Length Certification — from 10 Meg to 10 Gig

Automated optical loss measurement that provides immediate pass/fail link status based on industry standards.

Most industry standards and customer work statements require loss measurements to certify a fiber link. With OptiFiber’s optional loss/length certification module, you can have the same powerful loss certification capability as found in our fiber test adapters. Only OptiFiber offers a single module that integrates both insertion loss and OTDR certification, minimizing the number of tools you need to carry with you into the field.

Loss/length certification provides the fastest certification solution possible. This certification solution uses a main unit and a smart remote so that in one automated operation the OptiFiber:

  • tests two fibers, a transmit and receive pair, at two wavelengths
  • measures fiber length using the time of flight technique
  • measures insertion loss of both fibers at both wavelengths
  • enables bi-directional testing without having to swap main and remote units
  • calculates the loss budget and compares the results to a user-defined test limit
  • immediately displays the pass/fail link status

This proven test methodology yields the most links tested in the least amount of time. You can drill down into the data to view details useful in link analysis and troubleshooting. OptiFiber also incorporates the timesaving FindFiber feature enabling users at both ends to quickly check and correct link continuity.

Utilizing LinkWare Cable Test Management software you can easily save all fiber link data electronically for results management and report generation.

Fiber End-face Inspection

More than 85% of all fiber failures encountered are due to contaminated fiber end-faces. Such contamination is easily seen with OptiFiber’s video inspection system. View end-faces under 250x or 400x magnification.

You can inspect fibers installed in patch panels and devices without disassembly with OptiFiber’s video probes. The probe is inserted through bulkhead adapters letting you test 10 times faster than traditional scopes. And it’s safer on your eyes, too.

With FiberInspector you can see the condition of the fiber end-face. You can assign a pass or fail grade to the fiber and append a comment. You can apply a scale to help determine the fiber type. And you can save the image for use in certification reports and other documents.

ChannelMap View

Troubleshooting starts here with a simple link diagram that technicians can easily read and interpret.

OptiFiber’s ChannelMap presents the OTDR data in a simple diagram, or map, showing the number and location of connectors. No interpretation necessary. OptiFiber is the only OTDR solution available with this unique technician-friendly feature.

With ChannelMap you can:

  • quickly verify the composition of the link
  • identify patch cables as short as 1 meter in length

Document the link ChannelMap with LinkWare Cable Test Management software.

Power Meter

You may need a direct measurement of optical power to aid in source and link performance verification. With OptiFiber’s optional power meter module, you have 850nm, 1300nm, 1310nm and 1550nm optical power measurement capability. A single module integrates both power meter and OTDR capabilities, minimizing the number of tools you need to carry with you into the field. All loss/length modules are also capable of making power measurements.

With OptiFiber:

  • verify source and link performance
  • measure optical power at 850, 1300/1310 and 1550 nm
  • display power in dBm or µW
  • show min/max power over the duration of the test
  • save the results and append comments

Power measurements require a remote light source. Optical sources are available from Fluke Networks as accessories or use your existing calibrated sources.

Results Management

Fluke Networks’ powerful LinkWare Softwarel included with every OptiFiber helps you quickly organize, edit, view, print, save, or archive test results by jobsite, customer, campus building, and more. You can merge test results into an existing database and then sort, search and organize by any number of data fields or parameters.

LinkWare is also available free from our web site. Once your work is done, you can give this powerful application to your customer so they can have instant access to the data electronically or you can export the data as an Adobe Portable Document Format (PDF).

Extensive data management capabilities with LinkWare:

  • direct data import directly from OptiFiber, a computer file or an MMC device
  • summary or detailed views that can include OTDR test information and plots at two wavelengths from both ends
  • two OTDR trace view modes: compare to reference fiber, and multiple fiber traces (up to 12 simultaneously)
  • merge OTDR and loss/length test results into a single record
  • export results to Bellcore GR-196-CORE format
  • ChannelMap diagram
  • fiber end-face images from both ends of the link
  • bi-directional loss/length certification results
  • power meter measurements
  • OptiFiber OTDR emulation to study and analyze traces in the office
  • summary or detailed printed graphical reports in color, gray scale or in Adobe Portable Document (PDF) format
  • drag and drop multiple project management
  • compatibility with the TIA 606-A labeling hierarchy
  • share file with remote users

No other fiber test solution documents the fiber infrastructure so completely and easily.

Easy-to-Use Interface

OptiFiber makes it easy to test fiber – with an intuitive user interface and a lightweight handheld footprint that mimics our user-friendly copper-based certification solutions. Now troubleshooting fiber and testing to the latest industry standards is as quick and easy as pushing a button.

Storing and transfering fiber test results is simple and effortless with OptiFiber’s data mobility features. OptiFiber boasts an MMC (MultiMedia Card) drive and internal non-volatile memory for records storage. A 32MB card is included with every OptiFiber and 128MB MMC are available. This portable storage medium allows your OptiFiber to remain in the field while the data is sent to the office. And, it is easy to transfer data from OptiFiber to your PC. Use the RS-232 serial port or the high-speed USB interface. Or read data from your MMC with serial and USB MMC readers.

Every OptiFiber includes:

  • bright, color display for enhanced readability
  • sturdy integrated stand for table top operation
  • hanging strap when working off of racks
  • long-life battery with integrated charger and fuel gauge
  • keyboard port to speed data entry

A variety of accessories are available to enhance the power of your OptiFiber. Check out our selection of launch cables, carrying cases, camera probe options, light sources and other accessories.

OTDR Port Quality Check

OptiFiber is the only OTDR to incorporate an automated port quality check that warns the user when the OTDR port is dirty or contaminated. This is an important feature that can save users time while delivering a higher level of confidence in the OTDR test results. Over 70% of fiber test results that are inaccurate are due to dirty port connections, which means you may be spending hours trying to find the problem when the problem is in the port, not the fiber link.

OTDR port quality test automatically displays and evaluates the quality of the optical connection at the OTDR port with a Poor, Fair or Good rating. If the connection quality is poor or fair, a warning message appears so you can fix it before you do your OTDR testing.

Multiple Languages

OptiFiber speaks your language. The OptiFiber Certifying OTDR supports multiple languages for an even friendlier user experience.

The complete user interface and the extensive on-line help system are displayed in the language you select. The entire User Manual is available in many languages. Additionally the external keyboard reference diagram and the instruction sheets for the video probe, test modules, launch cables anf battery pack are available in multiple languages.

Available languages: English, French, German, Italian, Portuguese, Spanish, Chinese (simplified), and Japanese.

Modularity & Portability

OptiFiber is smaller and lighter than any other mini-OTDR available today, making it perfect for working in tight spaces and crowded distribution closets. Including a module and battery, OptiFiber weighs only 4.5 lb (1.9 kg) making it easy to work with in the field. This handheld solution is compact at 10.6 x 7.5 x 2.5 inches (26.9 x 19.1 x 6.4 cm) for outstanding maneuverability in tight spaces. It is built to withstand the harshest conditions of everyday field use with a vibration and shock resistant case and rugged tactile keypad.

If you’re selling your Fluke Networks OF-500 please fill out form on the right hand side of page.

Selling Fluke DTX-QUAD – We Buy New Used DTX-QUAD (‘s) Top Dollar Paid!

If you’re looking to Sell Fluke DTX-QUAD OTDR SM MM Fiber OTDR Module

The DTX Compact OTDR is a full featured Optical Time Domain Reflectometer (OTDR) module that snaps onto the Fluke Networks DTX CableAnalyzer. It makes the DTX powerful certification tool a complete, easy-to-use OTDR that shoots and analyzes traces on singlemode and multimode fiber.

The DTX Compact OTDR module makes every technician a fiber expert with unparalleled ease of use, automatic OTDR settings, loss limits for events and fiber links, launch fiber compensation, automatic event analysis, and results management – all with the familiar user interface of the DTX CableAnalyzer.

The DTX Compact OTDR Module leverages a contractor’s investment in the DTX CableAnalyzer by:

  • Expanding installation revenue without expanding staff
  • Shortening the technicians’ learning curve for fiber testing
  • Performing Basic (Tier 1) and Extended (Tier 2) fiber certification with a single tool
  • Accelerating troubleshooting with a powerful, single-ended OTDR
  • Delivering integrated copper and fiber reports using LinkWare™
  • Results Management Software

Buying, Selling, Trading Fluke DTX-QUAD

If you’re selling your Fluke DTX-QUAD please fill out form on the right hand side of page.

Selling Fluke Networks DTX-1800 – We Buy New Used DTX-1800 (‘s) Top Dollar Paid!

If you’re looking to Sell Fluke Networks DTX-1800 DTX-QUAD-OTDR Kit

Fluke Networks DTX-1800 Digital Cable Analyzer

The DTX CableAnalyzer™ Series from Fluke Networks is the testing platform for today and tomorrow. This revolutionary platform significantly reduces total time to certify by improving every aspect of the testing process. It all starts with a Cat 6 Autotest time that’s several times faster than other testers and fiber testing that’s five times faster. DTX also gives you a complete solution for 10 Gig testing over copper, Basic Tier 1 fiber testing, and Extended Tier 2 fiber testing with the industry’s only modular OTDR. The DTX makes you ready for whatever the world throws at you – today and tomorrow.

Significantly reduces total time to certify.

The DTX Digital CableAnalyzer Series gives you a complete solution that streamlines every aspect of the certification job from setup, to record fast testing and troubleshooting, to reporting results to the customer. All told, DTX can save you considerable time and money up to four hours a day.

Cat 6 certification in 9 seconds

The DTX-1200 and DTX-1800 perform Cat 6 certification tests in just 9 seconds in full compliance with industry standards and with superior accuracy. That’s several times faster than existing testers. This incredible speed means you can test up to 170 more links in an eight-hour shift.

Troubleshoot faults twice as fast

When a link fails, the DTX Series provides quick, easy-to-understand directions to identify the point of failure (distance from the tester) and the possible reason(s) for the failure.

These directions not only tell you the problem, but also identify corrective actions your test technicians can take to solve the problem quickly all without having to consult the project manager. Instead of spending time executing trial and error corrections – and re-testing to find out whether the problem has been resolved the technician knows exactly where to look and what to do to fix the failing link. Even if only two percent of the cables certified in one shift fail Autotest, you’ll save as much as two hours of labor time per day of certifying.

Buying, Selling, Trading Fluke Networks DTX-1800

Fast even when you’re not testing

The DTX Series isn’t just a faster way to test. It cuts setup and reporting times. Its ease-of-use lowers training time. Extended battery life means you can do more on a single charge. And a bright color display, ample memory, and built-in talk set all contribute to overall productivity while enhancing the user experience. This all adds up to save you time and money every day.

Enhance the power of DTX, Verify network service availability

Improve the services you offer your customers with the DTX CableAnalyzer and Network Service Module (DTX-NSM). Simply plug the DTX-NSM module into the back of the main unit and you’re ready to verify network service availability and link connectivity up to 1 Gigabit Ethernet. Verify if a link is active, identify its data rate, duplex capabilities and whether power is available for PoE. Then document all the network connectivity tests executed as an integrated part of the cable certification documentation provided by LinkWare.

Test cabling with Midspan PSEs for POE applications

Midspan power sources block DC power from traveling to the Ethernet switch or other active equipment in the wiring closet. This prohibits Wiremap tests of the link with conventional DC test methods. The DTX Series CableAnalyzer has the capability to test cabling using AC signals. This unique feature allows full certification to ISO and TIA standards where Midspan Power over Ethernet supplies are used.

Certify patch cord performance

Test patch cords to ensure optimal network performance with greater channel throughput and greater system margin. Attach the optional DTX Patch Cord Adapters (DTX-PCU6S) to the DTX main and remote units and you’re ready to certify patch cord performance to TIA Cat 6/5e specifications and also ISO class D/E.

Test coaxial cable quickly and easily

Extend the capabilities of your DTX CableAnalyzer to test coaxial cabling systems including legacy data cabling (such as 10BASE-2 or 10BASE-5 Ethernet) and video distribution coaxial cabling. Test coax cable length, propagation delay, cable (input) impedance and insertion loss as a function of signal frequency.

Fluke Networks DTX-MFM2

Add fiber optic test and network verification cabling to your DTX cable analyzer. Certify cable and fiber loss, length and polarity, verify network service availability and, link connectivity, and document in one LinkWare report. Includes two modules one for Main and one for Smart Remote, 850nm and 1300nm LED sources combined into single output port, 850/1300/1310/1550 nm power meter, and integrated VFL, 62.5/125 SC-SC test cables, and adapters.

Features:

  • Fiber on-board when you need it
  • Five times faster than existing testers with 12-second Autotest
  • Delivers Tier 1 LinkWare fiber certification reports
  • Locates fibers, verifies continuity and polarity, and finds breaks with built-in VFL
  • Speeds testing with TALK, FINDFIBER, MONITOR, bi-directional and single fiber test features
  • Functions as a Fluke Networks OptiFiber Certifying OTDR Smart Remote

Fluke Networks DTX-SFM2

DTX Singlemode Fiber Modules – Includes two modules (one for Main and one for Smart Remote). each module contains 1310 nm and 1550 nm laser light source combined into single output port, 850-1550 nm power meter, integrated VFL, SC adapter for power meter and Singlemode SC-SC Test Reference Cords.

Fluke Networks’ DTX-SFM2 set of two DTX Fiber Modules adds record-fast singlemode fiber certification and fault location to the DTX CableAnalyzer™ Series. Only Fluke Networks’ DTX platform offers optional on-board fiber modules so you’ll never lose time searching for your fiber adapter. Modules are easy to insert into the back of any DTX Series CableAnalyzer. With a resident fiber module on board, fiber certification is always ready when you are. No other solution lets you switch between copper and fiber with a touch of a button.

These modules deliver the greatest time and cost savings. They accelerate testing through exclusive technology and an easy-to-use interface. Press the Autotest button and you get standards-compliant certification automatically. Test two fibers each at two wavelengths, measure length and determine the pass or fail status — all in about 12 seconds. That’s five times faster than other adapters. These modules let you test more fibers in less time, cutting testing costs and freeing you up for other tasks. They can easily save more than 100 labor hours per year.

DTX-SFM fiber modules use laser sources to ensure standards-compliant certification of singlemode fiber. Speed testing with TALK, FINDFIBER, MONITOR, bi-directional and single fiber test features. Save, upload, manage and print comprehensive certification reports using LinkWare PC software.

These comprehensive Tier 1 certification solutions include loss, attenuation, length and polarity measurements. You can validate fiber link performance and installation quality. Measure optical loss at multiple wavelengths. And bi-directionally test fibers at two wavelengths without swapping near- and far-end units. Deliver Tier 1 fiber certification reports by uploading test results to LinkWare PC software.

An integrated on-module visual fault locator (VFL) makes troubleshooting simple link problems quick and incredibly easy. The bright laser-driven VFL helps you locate many near-end fiber faults. Also use it to locate fibers as well as verify continuity and polarity. Exclusive integrated design ensures the visual fault locator is always on hand when you need it.

If you’re selling your Fluke Networks DTX-1800 please fill out form on the right hand side of page.

Selling Fluke Networks OF-500 – We Buy New Used OF-500 (‘s) Top Dollar Paid!

 If you’re looking to Sell Fluke Networks OF-500 OptiFiber SM OTDR OFTM-5730Features

  • Tier 2 Fiber Certification
  • Powerful Diagnostics
  • Auto OTDR Analysis
  • Loss Length Certification
  • Fiber End-face Inspection
  • ChannelMap View
  • Power Meter
  • Results Management
  • Easy-to-use Interface
  • OTDR Port Check
  • Multiple Languages
  • Modularity and Portability

 

With OptiFiber, network engineers have in-house capability to:

  • Perform inspection, verification, certification, troubleshooting, and documentation of fiber cabling in a single, easy tool
  • Save time and money when diagnosing fiber cabling problems that are causing network performance issues
  • Easily locate and eliminate fiber problems
  • Check the work of subcontractors

Channel

Description

As bandwidth increases to more than 10 Gb/s, the use of fiber optics in premise networks continues to grow- and so do the requirements for testing and certifying it. To ensure the performance of mission-critical fiber infrastructure, network owners need a more complete picture of their fiber plant. And no solution provides a more complete picture than OptiFiber.

OptiFiber integrates power/loss, fiber length measurement, OTDR analysis and fiber connector end-face imaging to provide a higher tier of fiber certification and diagnostics. The companion LinkWare PC software documents, reports and manages all test data.

OptiFiber enables network owners of all experience levels to certify fiber to customer specifications and new industry standards, troubleshoot connection-rich links, and thoroughly document results. It will improve the health of your fiber network. Your fiber cabling will be ready and capable to perform for high-bandwidth applications.

 

 


Tier 2 Fiber Certification

Applications such as 10 Gb/s Ethernet require lower losses and higher quality installations. OptiFiber advances the testing of premise fiber optic cabling, providing all the individual tests and documentation required to ensure the cable plant was correctly installed in accordance with best professional practices and new standards.

The TIA TSB-140 includes two tiers of testing that can be chosen by a designer to be specified in a project. Tier 1 accommodates loss and length testing with an optical loss test set (OLTS). Tier 2 testing includes the parameters of Tier 1 and also an OTDR trace of the installed cable plant. By incorporating the proposed two-tier testing method, installers have the most complete picture of the fiber installation and network owners have proof of a quality installation. Recent IEC standards also include the recommendation of a second level of testing.

OptiFiber delivers on Tier 2 certification by integrating bi-directional two-fiber dual-wavelength insertion loss and automated OTDR pass/fail link analysis a one-two combination you will find only with OptiFiber. But OptiFiber doesn’t stop there. It also offers fiber endface grading. Only with OptiFiber can you certify every link with one tool by:

  • measuring loss and length
  • analyzing the OTDR trace
  • grading the connector end-face

Then use the companion LinkWare cable test management software to present this test data in a single certification report that can be archived or submitted as proof of a properly installed and terminated installation.

Powerful Diagnostics

OptiFiber integrates the features that matter most when troubleshooting enterprise networks. These networks are characterized by relatively short lengths of fiber within data centers or between buildings. Fibers are terminated with connectors and segments connected with short patch cables. No other OTDR let’s you see both ends of short patch cables, allowing you to see the condition of your connectors so you can quickly and efficiently diagnose and fix the problem.

OptiFiber leads the industry with:

  • event characterization analysis
  • advanced multimode modules with event deadzone of .5 meter at 850nm
  • advanced singlemode modules with event deadzones of 1 meter at 1310/1550 nm
  • a unique map of the channel that illustrates the location of all connectors
  • automated OTDR trace and event test limits
  • 250x and 400x high magnification video end-face inspection

Document the condition of your network with LinkWare Cable Test Management software.


Auto OTDR Analysis

OptiFiber simplifies OTDR analysis by automating certification and troubleshooting. In Auto OTDR mode OptiFiber automatically:

  • optimizes launch conditions for the best resolution
  • makes dual wavelength OTDR measurements – 850/1300 nm or 1310/1550 nm
  • identifies and characterizes the fiber link and its events
  • compares the results to user-defined limits for immediate pass/fail link and event certification
  • saves time spent setting and moving cursors

For advanced troubleshooting you can view a trace at two wavelengths. Automatically step from one event to the next and zoom in on those of interest. Measure event loss. Events are also summarized in a table. Save the information for LinkWare reporting.

You may also choose to operate OptiFiber in manual mode so you can set the test parameters yourself.


Loss/Length Certification — from 10 Meg to 10 Gig

Automated optical loss measurement that provides immediate pass/fail link status based on industry standards.

Most industry standards and customer work statements require loss measurements to certify a fiber link. With OptiFiber’s optional loss/length certification module, you can have the same powerful loss certification capability as found in our fiber test adapters. Only OptiFiber offers a single module that integrates both insertion loss and OTDR certification, minimizing the number of tools you need to carry with you into the field.

Loss/length certification provides the fastest certification solution possible. This certification solution uses a main unit and a smart remote so that in one automated operation the OptiFiber:

  • tests two fibers, a transmit and receive pair, at two wavelengths
  • measures fiber length using the time of flight technique
  • measures insertion loss of both fibers at both wavelengths
  • enables bi-directional testing without having to swap main and remote units
  • calculates the loss budget and compares the results to a user-defined test limit
  • immediately displays the pass/fail link status

This proven test methodology yields the most links tested in the least amount of time. You can drill down into the data to view details useful in link analysis and troubleshooting. OptiFiber also incorporates the timesaving FindFiber feature enabling users at both ends to quickly check and correct link continuity.

Utilizing LinkWare Cable Test Management software you can easily save all fiber link data electronically for results management and report generation.


Fiber End-face Inspection

More than 85% of all fiber failures encountered are due to contaminated fiber end-faces. Such contamination is easily seen with OptiFiber’s video inspection system. View end-faces under 250x or 400x magnification.

You can inspect fibers installed in patch panels and devices without disassembly with OptiFiber’s video probes. The probe is inserted through bulkhead adapters letting you test 10 times faster than traditional scopes. And it’s safer on your eyes, too.

With FiberInspector you can see the condition of the fiber end-face. You can assign a pass or fail grade to the fiber and append a comment. You can apply a scale to help determine the fiber type. And you can save the image for use in certification reports and other documents.


ChannelMap View

Troubleshooting starts here with a simple link diagram that technicians can easily read and interpret.

OptiFiber’s ChannelMap presents the OTDR data in a simple diagram, or map, showing the number and location of connectors. No interpretation necessary. OptiFiber is the only OTDR solution available with this unique technician-friendly feature.

With ChannelMap you can:

  • quickly verify the composition of the link
  • identify patch cables as short as 1 meter in length

Document the link ChannelMap with LinkWare Cable Test Management software.


Power Meter

You may need a direct measurement of optical power to aid in source and link performance verification. With OptiFiber’s optional power meter module, you have 850nm, 1300nm, 1310nm and 1550nm optical power measurement capability. A single module integrates both power meter and OTDR capabilities, minimizing the number of tools you need to carry with you into the field. All loss/length modules are also capable of making power measurements.

With OptiFiber:

  • verify source and link performance
  • measure optical power at 850, 1300/1310 and 1550 nm
  • display power in dBm or µW
  • show min/max power over the duration of the test
  • save the results and append comments

Power measurements require a remote light source. Optical sources are available from Fluke Networks as accessories or use your existing calibrated sources.


Results Management

Fluke Networks’ powerful LinkWare Softwarel included with every OptiFiber helps you quickly organize, edit, view, print, save, or archive test results by jobsite, customer, campus building, and more. You can merge test results into an existing database and then sort, search and organize by any number of data fields or parameters.

LinkWare is also available free from our web site. Once your work is done, you can give this powerful application to your customer so they can have instant access to the data electronically or you can export the data as an Adobe Portable Document Format (PDF).

Extensive data management capabilities with LinkWare:

  • direct data import directly from OptiFiber, a computer file or an MMC device
  • summary or detailed views that can include OTDR test information and plots at two wavelengths from both ends
  • two OTDR trace view modes: compare to reference fiber, and multiple fiber traces (up to 12 simultaneously)
  • merge OTDR and loss/length test results into a single record
  • export results to Bellcore GR-196-CORE format
  • ChannelMap diagram
  • fiber end-face images from both ends of the link
  • bi-directional loss/length certification results
  • power meter measurements
  • OptiFiber OTDR emulation to study and analyze traces in the office
  • summary or detailed printed graphical reports in color, gray scale or in Adobe Portable Document (PDF) format
  • drag and drop multiple project management
  • compatibility with the TIA 606-A labeling hierarchy
  • share file with remote users

No other fiber test solution documents the fiber infrastructure so completely and easily.


Easy-to-Use Interface

OptiFiber makes it easy to test fiber – with an intuitive user interface and a lightweight handheld footprint that mimics our user-friendly copper-based certification solutions. Now troubleshooting fiber and testing to the latest industry standards is as quick and easy as pushing a button.

Storing and transfering fiber test results is simple and effortless with OptiFiber’s data mobility features. OptiFiber boasts an MMC (MultiMedia Card) drive and internal non-volatile memory for records storage. A 32MB card is included with every OptiFiber and 128MB MMC are available. This portable storage medium allows your OptiFiber to remain in the field while the data is sent to the office. And, it is easy to transfer data from OptiFiber to your PC. Use the RS-232 serial port or the high-speed USB interface. Or read data from your MMC with serial and USB MMC readers.

Every OptiFiber includes:

  • bright, color display for enhanced readability
  • sturdy integrated stand for table top operation
  • hanging strap when working off of racks
  • long-life battery with integrated charger and fuel gauge
  • keyboard port to speed data entry

A variety of accessories are available to enhance the power of your OptiFiber. Check out our selection of launch cables, carrying cases, camera probe options, light sources and other accessories.


OTDR Port Quality Check

OptiFiber is the only OTDR to incorporate an automated port quality check that warns the user when the OTDR port is dirty or contaminated. This is an important feature that can save users time while delivering a higher level of confidence in the OTDR test results. Over 70% of fiber test results that are inaccurate are due to dirty port connections, which means you may be spending hours trying to find the problem when the problem is in the port, not the fiber link.

OTDR port quality test automatically displays and evaluates the quality of the optical connection at the OTDR port with a Poor, Fair or Good rating. If the connection quality is poor or fair, a warning message appears so you can fix it before you do your OTDR testing.


Multiple Languages

OptiFiber speaks your language. The OptiFiber Certifying OTDR supports multiple languages for an even friendlier user experience.

The complete user interface and the extensive on-line help system are displayed in the language you select. The entire User Manual is available in many languages. Additionally the external keyboard reference diagram and the instruction sheets for the video probe, test modules, launch cables anf battery pack are available in multiple languages.

Available languages: English, French, German, Italian, Portuguese, Spanish, Chinese (simplified), and Japanese.


Modularity & Portability

OptiFiber is smaller and lighter than any other mini-OTDR available today, making it perfect for working in tight spaces and crowded distribution closets. Including a module and battery, OptiFiber weighs only 4.5 lb (1.9 kg) making it easy to work with in the field. This handheld solution is compact at 10.6 x 7.5 x 2.5 inches (26.9 x 19.1 x 6.4 cm) for outstanding maneuverability in tight spaces. It is built to withstand the harshest conditions of everyday field use with a vibration and shock resistant case and rugged tactile keypad.

Buying, Selling, Trading Fluke Networks OF-500

If you’re selling your Fluke Networks OF-500 please fill out form on the right hand side of page.