Description The OV 1000 is a compact modular Optical Time Domain Reflectometer (OTDR) which is designed for testing, documentation and troubleshooting in local area networks (LAN), Carrier-, CATV- and fiber-to-thex-(FTTx) fiber optic networks.

The device can accommodate two test modules. The available module options offer different combinations of wavelengths and dynamic ranges. Available wavelengths are 850 nm, 1,300 nm, 1,310 nm, 1,490 nm, 1,550 nm and 1,625 nm.

In addition to the test modules available in the common wavelength and dynamic range combinations, the option of integrated power meter and visual fault locator in the mainframe is another valuable addition which emphasizes the unit?s universal character. The test port of the OTDR module provides the light source function. In combination with the optional fiber inspection probe (FIP), the OV 1000 works as a universal test- and measurement device for all passive optical components of a network.

The mainframe is equipped with the Windows® CE Mobile operating system. This allows a fast boot-up time within a few seconds as well as intuitive userfriendly operation.

Besides the outstanding optical measurement performance, the versatile, modern and ergonomic design of the OV 1000 gives another clear advantage.

Beside the mainframe with 6.4 ?? touch screen and integrated 80 MB flash memory, the OV 1000 OTDR kits are supplied with the respective test module with SC UPC interface adapter(s), OTSView software for post processing on a PC, USB cable, one Li-Ion battery, power supply and power cord with EU connector as well as the deluxe transport case.

The deluxe transport case offers wheels and pull-out handle for maximum user-friendliness. It is equipped with two additional carrying handles. Its compact dimensions meet the requirements for airline carry-on luggage. The case is tight against water and dust. With its adapted padded inserts it offers protection against mechanical impacts for the OV 1000 and its accessories.

Features

  • Test and collect data up to four wavelengths by pressing only one button
  • Very fast acquisition time
  • Fast ready-to-measure boot-up time of 4 seconds
  • Simultaneous use of touch screen, short-cut keys and tracking knob for high user convenience
  • Maximum 128,000 data points for highest resolution
  • Attenuation resolution of 0.001 dB
  • Very short event dead zone of just 1 m and 4.5 m attenuation dead zone
  • 6.4 ? full VGA touch screen (optional transflective display for crisp viewing in bright sun light available)
  • Three test modes (auto, advanced and template) fit best to user skills and applications for maximum measurement convenience
  • Possible configurations cover all typical fiber applications from long-haul and WDM to metro networks, FTTx as well as LAN
  • Powerful Li-Ion battery provide mains independent operation time of more than 8 hours
  • Diverse storage options(in addition to 80 MB built-in flash memory two USB ports and a CompactFlash card slot)
  • Internal memory sufficient typically for up to 1,500 traces
  • Numerous connection ports for easy connectivity for convenient download and upgrade
  • 10 / 100 Mb/s Ethernet Cat.5 RJ-45 network interface
  • Rugged and waterproof housing for long life time
  • Low weight of only 2.5 kg (mainframe with one module and battery)

Buying, Selling, Trading Corning OV-1000

If you’re selling your Corning OV-1000 please fill out form on the right hand side of page.

Selling Siecor 340M-3610 – We Buy New Used 340M-3610 (‘s) Top Dollar Paid!

If you’re looking to Sell Siecor 340M-3610 Siecor Corning OTDR Plus Multitester II

Applications

LAN
Telco
CATV
Description
The Model 340 OTDR Plus™ Multitester II offers true multitesting capability that features field-installable single-mode, multimode and quad OTDR modules, visual fault locator, as well as optional built-in power meter and laser source. The standard unit provides internal solid-state memory for 125 traces and a floppy disk drive. An optional hard drive is also offered to allow mass data storage and speeds testing by eliminating the need to constantly exchange floppy disks in the standard drive. The product line offers a large variety of high-performance multimode and single-mode modules featuring a superior single-mode unit with 46 dB dynamic range. SoftView™ Emulation Software provides desktop analysis and quality documentation capability.

A large 10.4-in (26.4 cm) display is easy to read and eliminates the need to jump from screen to screen to view results. Because it is active matrix color, readability is further enhanced. The extraordinary strength, durability and weather resistance of the custom polymer housing protects your equipment investment.

Troubleshooting with the 340 is quick and easy with the SmartTest™ Function. At the touch of a button, the 340 selects the parameters and then tests the fiber. The DualTrace™ Function tests and displays both wavelengths on one graph. The multitasking operating system provides fast fiber analysis and data collection. The DualPulse feature allows measurement of the same fiber with two pulse widths to optimize resolution and distance measurements.

Repetitive testing and documentation of each fiber is reduced to the shortest possible time using the AutoIncrement™ Function. Only one button per fiber is needed to record both a trace and event table at both wavelengths. Pop-up dialog boxes guide you from fiber-to-fiber and provide warnings if a fault of above-threshold loss is found.

Features / Benefits

SmartTest™ Function provides a fast, one-button analysis of the entire fiber
AutoIncrement™ Function speeds up repetitive as-built testing in high-fiber-count projects, saving time, money and reducing error
DualTrace™ Function shows optimal traces at both wavelengths on one graph for easy analysis
Large variety of high-performance modules available – single-mode up to 46 dB offers significant distance capacity and enhances event search capabilities
Multitest capabilities offer all-in-one convenience on a field-upgradeable platform
SoftView™ Emulation Software for batch printing and editing, trace overlay and bidirectional analysis
Large display with active matrix color eases eyestrain during periods of extended use
Commercially available rechargeable batteries offer hours of autonomous operation
AC adapter as well as a 12 V DC power adapter
Multilingual operating and help screens
Quick and efficient location of fiber breaks and previous event for landmarking
Flexible Universal Connector System
Telcordia compliant, including GR-196 formatted traces
Level 3 approved

The Multitester Concept
The 340 combines single-mode, multimode and quad OTDR capabilities along with a power meter, visual fault locator and stabilized singlemode light source into a compact platform that resides in a rugged polymer housing. Virtually any field testing can be accomplished with the unit. Capabilities include incoming reel inspections, link loss measurements, fiber attenuation (dB/km), splice and connector loss, reflectance and optical return loss measurement, length measurement, visual fault location and a 2 kHz test tone for fiber identification. With the many range and test options available, the unit can be optimized for access, data center, telco or CATV applications. Specialty modules for water intrusion (1244 nm) S-band (1410 nm) and out of band (1625 nm) testing are also available. Because the platform is modular and field-installed, OTDR and VFL options not ordered initially can be added at a later date.

OTDR Functions
The 340 is two OTDRs in one – single-mode and multimode – making it ideal for LAN testing, where both fiber types are common. With up to 46 dB of single-mode range available, the 340 is a powerful tool for telco and CATV applications as well.

Power Meter
The built-in power meter options make end-toend testing easy because data can be saved to disk and analyzed/printed with the same software used for OTDR traces. For CATV applications, a range of +20 dBm is available.

Visual Fault Locator
The field-installable VFL makes fault location within the OTDR’s deadzone possible as well as provides visual continuity checks.

Single-mode Source
Units equipped with single-mode OTDR capability can also be equipped to function as a stabilized laser source for loss measurement.

2 kHz Test Tone
Fiber identifiers such as the CheckPoint™ and CheckPoint Plus can recognize this tone to locate a fiber at a splice or repair point.

Fault Locate Function
The OTDR operates as a simple fault locator. At the touch of a button, the unit quickly and accurately finds the end of the fiber.

SmartTest™ Function
Think of the SmartTest Function as the built-in expert. One key press will select the best parameters for the connected fiber, acquire the data and present both a trace and an event table on one screen. Both novice and expert will benefit from quick and complete fiber characterization. For the novice, getting good results requires only minimal equipment knowledge. For the expert, the SmartTest Function can quickly set machine parameters.

DualTrace™ Function
On one screen, the DualTrace Function characterizes a fiber at both wavelengths, optimizing the pulse width for each. Visual comparison of performance at each wavelength is greatly enhanced by combining both traces into one graph. Wavelength-dependent losses, such as bending and pinching in splice trays, tight bends in cable placement and compression due to temperature extremes, are also easier to identify in the DualTrace Function view. Such events will exhibit greater loss at the longer wavelength, both on the traces and in the event table.

DualPulse Function
A fiber is tested at a single wavelength with two pulse widths. Two traces are displayed, one for each pulsewidth. The short pulse provides optimal event resolution, while the longer pulse provides excellent distant measurements.

 

Buying, Selling, Trading Siecor 340M-3610

AutoIncrement™ Function
Documentation of new installations and repairs is performed quickly with the AutoIncrement Function. This function can create traces and event tables at both wavelengths, save them to disk and prompt the user for the next fiber when ready. If any un-acceptable losses are detected, the user is informed before proceeding. Sequential file names are automatically incremented for each fiber in the test.

Data Storage
Data is stored to either the internal solid-state memory, a standard floppy drive or an optional hard drive. More than 80,000 traces can be stored on the internal hard drive. Floppy disks may be created directly from the hard drive. Data can also be stored in other compatible file formats such as the standard Telcordia GR-196 format.

PC Emulation Software
SoftView™ Emulation Software turns a notebook or office PC into a fiber analysis workstation with powerful batch printing, reporting and editing tools. Virtually all the functions available on the OTDR are available on the PC for data stored to disk. SoftView Emulation Software provides manual operation with view trace, eight-trace compare, Telcordia GR-196 formatted trace measurement, save and recall, plus fast analysis and batch printing, fast templates, bidirectional analysis and global processing.

340M-5711 Specifications:

Center Wavelength
20/± 20 nm 850/1300 nm
1310/1550 nm
Dynamic Range
23/24 dB
33/31 dB
Attenuation Deadzone 8/9 m
11/12 m
Reflective Deadzone (typical) 3 m (multimode) / 3.5 m (single-mode)
Pulse width
(wavelength dependent) 4 ns to 10 µs (multimode); 10 ns to 30 µs (single-mode)
Spectral Width (RMS) 10 nm
Loss Resolution 0.001 dB
Distance Resolution 0.0001 km; 0.01 meters; 0.001 kft; 1ft; 0.0001 mi
Distance Sampling 0.25, 0.5, 1, 2, 4, 8, 16 m (range dependent)
Distance Accuracy 0.0025% of distance measurement +/- distance resolution +/- index uncertainty
Laser Certification CDRH class 1 requirements (eye safe) 21 CFR

Mainframe Specifications:

Display Type 10.4-in Active Matrix Color (TFT)
Units of Measure Meters, Feet (selectable)
Operating Temperature AC power: 0° to 45°C (32° to 122°F); Battery: 0° to 40°C (32° to 104°F)
Storage Temperature -20° to +60°C (-4° to 140°F)
Humidity 95% RH maximum, non-condensing
Maximum Altitude 50,000 ft
Power Supply Battery: 6 hr typical battery life-(2); recharge time: 1.5 to 2 hr;
AC: 100-250 V, 47-63 Hz; Autoranging: 12 V DC operation
Weight 11.0 lb (4.9 kg) includes battery and module
Dimensions 9.5 x 13.5 x 3.75 in (24.1 x 34.3 x 9.5 cm); includes mainframe, 1 module and battery
Data Points Up to 16,000
Tone for Fiber Identification 2 kHz
Mass Storage Internal Solid-State Memory: up to 125 traces; floppy (included): 1.44 Mb, 3.5-in;
hard drive (optional): over 80,000 traces

VFL Specifications:

Wavelength 635 ± 10 nm
Output Power = -2 dBm (0 dBm max)
Transmission CW or 2 Hz (blink)
Connector (fixed) FC, SC, or ST® Compatible
Laser Certification IEC 825 Class 2, FDA (21CFR), Class 2

Power Meter Specifications:

Calibrated Wavelengths 850/1300/1310/1550nm
Optical Meter Range
(factory-installed) Standard: +10 to -55 dBm
CATV: +20 to -45 dBm, with mf-460 filter
Detector Type 2 mm Ge PIN photodiode
Wavelength 800 – 1800 nm
Resolution 0.01 dBm, 0.01% Watts
Store Reference Mode Yes
Accuracy ± 4% @ +5 to -50 dBm
± 8% @ +10 to +5 dBm and @ -50 to -55 dBm
Linearity ± 0.04 dB, +5 to -55 dBm

If you’re selling your Siecor 340M-3610 please fill out form on the right hand side of page.

Selling Siecor 340M-5711 – We Buy New Used 340M-5711 (‘s) Top Dollar Paid!

If you’re looking to Sell Siecor 340M-5711 Corning Siecor OTDR Plus Multitester II

Applications

LAN
Telco
CATV
Description
The Model 340 OTDR Plus™ Multitester II offers true multitesting capability that features field-installable single-mode, multimode and quad OTDR modules, visual fault locator, as well as optional built-in power meter and laser source. The standard unit provides internal solid-state memory for 125 traces and a floppy disk drive. An optional hard drive is also offered to allow mass data storage and speeds testing by eliminating the need to constantly exchange floppy disks in the standard drive. The product line offers a large variety of high-performance multimode and single-mode modules featuring a superior single-mode unit with 46 dB dynamic range. SoftView™ Emulation Software provides desktop analysis and quality documentation capability.

A large 10.4-in (26.4 cm) display is easy to read and eliminates the need to jump from screen to screen to view results. Because it is active matrix color, readability is further enhanced. The extraordinary strength, durability and weather resistance of the custom polymer housing protects your equipment investment.

Troubleshooting with the 340 is quick and easy with the SmartTest™ Function. At the touch of a button, the 340 selects the parameters and then tests the fiber. The DualTrace™ Function tests and displays both wavelengths on one graph. The multitasking operating system provides fast fiber analysis and data collection. The DualPulse feature allows measurement of the same fiber with two pulse widths to optimize resolution and distance measurements.

Repetitive testing and documentation of each fiber is reduced to the shortest possible time using the AutoIncrement™ Function. Only one button per fiber is needed to record both a trace and event table at both wavelengths. Pop-up dialog boxes guide you from fiber-to-fiber and provide warnings if a fault of above-threshold loss is found.

Features / Benefits

SmartTest™ Function provides a fast, one-button analysis of the entire fiber
AutoIncrement™ Function speeds up repetitive as-built testing in high-fiber-count projects, saving time, money and reducing error
DualTrace™ Function shows optimal traces at both wavelengths on one graph for easy analysis
Large variety of high-performance modules available – single-mode up to 46 dB offers significant distance capacity and enhances event search capabilities
Multitest capabilities offer all-in-one convenience on a field-upgradeable platform
SoftView™ Emulation Software for batch printing and editing, trace overlay and bidirectional analysis
Large display with active matrix color eases eyestrain during periods of extended use
Commercially available rechargeable batteries offer hours of autonomous operation
AC adapter as well as a 12 V DC power adapter
Multilingual operating and help screens
Quick and efficient location of fiber breaks and previous event for landmarking
Flexible Universal Connector System
Telcordia compliant, including GR-196 formatted traces
Level 3 approved

The Multitester Concept
The 340 combines single-mode, multimode and quad OTDR capabilities along with a power meter, visual fault locator and stabilized singlemode light source into a compact platform that resides in a rugged polymer housing. Virtually any field testing can be accomplished with the unit. Capabilities include incoming reel inspections, link loss measurements, fiber attenuation (dB/km), splice and connector loss, reflectance and optical return loss measurement, length measurement, visual fault location and a 2 kHz test tone for fiber identification. With the many range and test options available, the unit can be optimized for access, data center, telco or CATV applications. Specialty modules for water intrusion (1244 nm) S-band (1410 nm) and out of band (1625 nm) testing are also available. Because the platform is modular and field-installed, OTDR and VFL options not ordered initially can be added at a later date.

OTDR Functions
The 340 is two OTDRs in one – single-mode and multimode – making it ideal for LAN testing, where both fiber types are common. With up to 46 dB of single-mode range available, the 340 is a powerful tool for telco and CATV applications as well.

Power Meter
The built-in power meter options make end-toend testing easy because data can be saved to disk and analyzed/printed with the same software used for OTDR traces. For CATV applications, a range of +20 dBm is available.

Visual Fault Locator
The field-installable VFL makes fault location within the OTDR’s deadzone possible as well as provides visual continuity checks.

Single-mode Source
Units equipped with single-mode OTDR capability can also be equipped to function as a stabilized laser source for loss measurement.

2 kHz Test Tone
Fiber identifiers such as the CheckPoint™ and CheckPoint Plus can recognize this tone to locate a fiber at a splice or repair point.

Fault Locate Function
The OTDR operates as a simple fault locator. At the touch of a button, the unit quickly and accurately finds the end of the fiber.

SmartTest™ Function
Think of the SmartTest Function as the built-in expert. One key press will select the best parameters for the connected fiber, acquire the data and present both a trace and an event table on one screen. Both novice and expert will benefit from quick and complete fiber characterization. For the novice, getting good results requires only minimal equipment knowledge. For the expert, the SmartTest Function can quickly set machine parameters.

DualTrace™ Function
On one screen, the DualTrace Function characterizes a fiber at both wavelengths, optimizing the pulse width for each. Visual comparison of performance at each wavelength is greatly enhanced by combining both traces into one graph. Wavelength-dependent losses, such as bending and pinching in splice trays, tight bends in cable placement and compression due to temperature extremes, are also easier to identify in the DualTrace Function view. Such events will exhibit greater loss at the longer wavelength, both on the traces and in the event table.

DualPulse Function
A fiber is tested at a single wavelength with two pulse widths. Two traces are displayed, one for each pulsewidth. The short pulse provides optimal event resolution, while the longer pulse provides excellent distant measurements..

 

Buying, Selling, Trading Siecor 340M-5711
AutoIncrement™ Function
Documentation of new installations and repairs is performed quickly with the AutoIncrement Function. This function can create traces and event tables at both wavelengths, save them to disk and prompt the user for the next fiber when ready. If any un-acceptable losses are detected, the user is informed before proceeding. Sequential file names are automatically incremented for each fiber in the test.

Data Storage
Data is stored to either the internal solid-state memory, a standard floppy drive or an optional hard drive. More than 80,000 traces can be stored on the internal hard drive. Floppy disks may be created directly from the hard drive. Data can also be stored in other compatible file formats such as the standard Telcordia GR-196 format.

PC Emulation Software
SoftView™ Emulation Software turns a notebook or office PC into a fiber analysis workstation with powerful batch printing, reporting and editing tools. Virtually all the functions available on the OTDR are available on the PC for data stored to disk. SoftView Emulation Software provides manual operation with view trace, eight-trace compare, Telcordia GR-196 formatted trace measurement, save and recall, plus fast analysis and batch printing, fast templates, bidirectional analysis and global processing.

340M-5711 Specifications:

Center Wavelength
20/± 20 nm 850/1300 nm
1310/1550 nm
Dynamic Range
23/24 dB
33/31 dB
Attenuation Deadzone 8/9 m
11/12 m
Reflective Deadzone (typical) 3 m (multimode) / 3.5 m (single-mode)
Pulse width
(wavelength dependent) 4 ns to 10 µs (multimode); 10 ns to 30 µs (single-mode)
Spectral Width (RMS) 10 nm
Loss Resolution 0.001 dB
Distance Resolution 0.0001 km; 0.01 meters; 0.001 kft; 1ft; 0.0001 mi
Distance Sampling 0.25, 0.5, 1, 2, 4, 8, 16 m (range dependent)
Distance Accuracy 0.0025% of distance measurement +/- distance resolution +/- index uncertainty
Laser Certification CDRH class 1 requirements (eye safe) 21 CFR

Mainframe Specifications:

Display Type 10.4-in Active Matrix Color (TFT)
Units of Measure Meters, Feet (selectable)
Operating Temperature AC power: 0° to 45°C (32° to 122°F); Battery: 0° to 40°C (32° to 104°F)
Storage Temperature -20° to +60°C (-4° to 140°F)
Humidity 95% RH maximum, non-condensing
Maximum Altitude 50,000 ft
Power Supply Battery: 6 hr typical battery life-(2); recharge time: 1.5 to 2 hr;
AC: 100-250 V, 47-63 Hz; Autoranging: 12 V DC operation
Weight 11.0 lb (4.9 kg) includes battery and module
Dimensions 9.5 x 13.5 x 3.75 in (24.1 x 34.3 x 9.5 cm); includes mainframe, 1 module and battery
Data Points Up to 16,000
Tone for Fiber Identification 2 kHz
Mass Storage Internal Solid-State Memory: up to 125 traces; floppy (included): 1.44 Mb, 3.5-in;
hard drive (optional): over 80,000 traces

VFL Specifications:

Wavelength 635 ± 10 nm
Output Power = -2 dBm (0 dBm max)
Transmission CW or 2 Hz (blink)
Connector (fixed) FC, SC, or ST® Compatible
Laser Certification IEC 825 Class 2, FDA (21CFR), Class 2

Power Meter Specifications:

Calibrated Wavelengths 850/1300/1310/1550nm
Optical Meter Range
(factory-installed) Standard: +10 to -55 dBm
CATV: +20 to -45 dBm, with mf-460 filter
Detector Type 2 mm Ge PIN photodiode
Wavelength 800 – 1800 nm
Resolution 0.01 dBm, 0.01% Watts
Store Reference Mode Yes
Accuracy ± 4% @ +5 to -50 dBm
± 8% @ +10 to +5 dBm and @ -50 to -55 dBm
Linearity ± 0.04 dB, +5 to -55 dBm

 

If you’re selling your Siecor 340M-5711 please fill out form on the right hand side of page.

Selling Siecor 340M-6 – We Buy New Used 340M-6 (‘s) Top Dollar Paid!

If you’re looking to Sell Siecor 340M-6 Siecor Corning SM OTDR Plus Multitester II

Applications

LAN
Telco
CATV
Description
The Model 340 OTDR Plus™ Multitester II offers true multitesting capability that features field-installable single-mode, multimode and quad OTDR modules, visual fault locator, as well as optional built-in power meter and laser source. The standard unit provides internal solid-state memory for 125 traces and a floppy disk drive. An optional hard drive is also offered to allow mass data storage and speeds testing by eliminating the need to constantly exchange floppy disks in the standard drive. The product line offers a large variety of high-performance multimode and single-mode modules featuring a superior single-mode unit with 46 dB dynamic range. SoftView™ Emulation Software provides desktop analysis and quality documentation capability.

A large 10.4-in (26.4 cm) display is easy to read and eliminates the need to jump from screen to screen to view results. Because it is active matrix color, readability is further enhanced. The extraordinary strength, durability and weather resistance of the custom polymer housing protects your equipment investment.

Troubleshooting with the 340 is quick and easy with the SmartTest™ Function. At the touch of a button, the 340 selects the parameters and then tests the fiber. The DualTrace™ Function tests and displays both wavelengths on one graph. The multitasking operating system provides fast fiber analysis and data collection. The DualPulse feature allows measurement of the same fiber with two pulse widths to optimize resolution and distance measurements.

Repetitive testing and documentation of each fiber is reduced to the shortest possible time using the AutoIncrement™ Function. Only one button per fiber is needed to record both a trace and event table at both wavelengths. Pop-up dialog boxes guide you from fiber-to-fiber and provide warnings if a fault of above-threshold loss is found.

Features / Benefits

SmartTest™ Function provides a fast, one-button analysis of the entire fiber
AutoIncrement™ Function speeds up repetitive as-built testing in high-fiber-count projects, saving time, money and reducing error
DualTrace™ Function shows optimal traces at both wavelengths on one graph for easy analysis
Large variety of high-performance modules available – single-mode up to 46 dB offers significant distance capacity and enhances event search capabilities
Multitest capabilities offer all-in-one convenience on a field-upgradeable platform
SoftView™ Emulation Software for batch printing and editing, trace overlay and bidirectional analysis
Large display with active matrix color eases eyestrain during periods of extended use
Commercially available rechargeable batteries offer hours of autonomous operation
AC adapter as well as a 12 V DC power adapter
Multilingual operating and help screens
Quick and efficient location of fiber breaks and previous event for landmarking
Flexible Universal Connector System
Telcordia compliant, including GR-196 formatted traces
Level 3 approved

The Multitester Concept
The 340 combines single-mode, multimode and quad OTDR capabilities along with a power meter, visual fault locator and stabilized singlemode light source into a compact platform that resides in a rugged polymer housing. Virtually any field testing can be accomplished with the unit. Capabilities include incoming reel inspections, link loss measurements, fiber attenuation (dB/km), splice and connector loss, reflectance and optical return loss measurement, length measurement, visual fault location and a 2 kHz test tone for fiber identification. With the many range and test options available, the unit can be optimized for access, data center, telco or CATV applications. Specialty modules for water intrusion (1244 nm) S-band (1410 nm) and out of band (1625 nm) testing are also available. Because the platform is modular and field-installed, OTDR and VFL options not ordered initially can be added at a later date.

OTDR Functions
The 340 is two OTDRs in one – single-mode and multimode – making it ideal for LAN testing, where both fiber types are common. With up to 46 dB of single-mode range available, the 340 is a powerful tool for telco and CATV applications as well.

Power Meter
The built-in power meter options make end-toend testing easy because data can be saved to disk and analyzed/printed with the same software used for OTDR traces. For CATV applications, a range of +20 dBm is available.

Visual Fault Locator
The field-installable VFL makes fault location within the OTDR’s deadzone possible as well as provides visual continuity checks.

Single-mode Source
Units equipped with single-mode OTDR capability can also be equipped to function as a stabilized laser source for loss measurement.

2 kHz Test Tone
Fiber identifiers such as the CheckPoint™ and CheckPoint Plus can recognize this tone to locate a fiber at a splice or repair point.

Fault Locate Function
The OTDR operates as a simple fault locator. At the touch of a button, the unit quickly and accurately finds the end of the fiber.

SmartTest™ Function
Think of the SmartTest Function as the built-in expert. One key press will select the best parameters for the connected fiber, acquire the data and present both a trace and an event table on one screen. Both novice and expert will benefit from quick and complete fiber characterization. For the novice, getting good results requires only minimal equipment knowledge. For the expert, the SmartTest Function can quickly set machine parameters.

DualTrace™ Function
On one screen, the DualTrace Function characterizes a fiber at both wavelengths, optimizing the pulse width for each. Visual comparison of performance at each wavelength is greatly enhanced by combining both traces into one graph. Wavelength-dependent losses, such as bending and pinching in splice trays, tight bends in cable placement and compression due to temperature extremes, are also easier to identify in the DualTrace Function view. Such events will exhibit greater loss at the longer wavelength, both on the traces and in the event table.

DualPulse Function
A fiber is tested at a single wavelength with two pulse widths. Two traces are displayed, one for each pulsewidth. The short pulse provides optimal event resolution, while the longer pulse provides excellent distant measurements.

AutoIncrement™ Function
Documentation of new installations and repairs is performed quickly with the AutoIncrement Function. This function can create traces and event tables at both wavelengths, save them to disk and prompt the user for the next fiber when ready. If any un-acceptable losses are detected, the user is informed before proceeding. Sequential file names are automatically incremented for each fiber in the test.

Data Storage
Data is stored to either the internal solid-state memory, a standard floppy drive or an optional hard drive. More than 80,000 traces can be stored on the internal hard drive. Floppy disks may be created directly from the hard drive. Data can also be stored in other compatible file formats such as the standard Telcordia GR-196 format.

PC Emulation Software
SoftView™ Emulation Software turns a notebook or office PC into a fiber analysis workstation with powerful batch printing, reporting and editing tools. Virtually all the functions available on the OTDR are available on the PC for data stored to disk. SoftView Emulation Software provides manual operation with view trace, eight-trace compare, Telcordia GR-196 formatted trace measurement, save and recall, plus fast analysis and batch printing, fast templates, bidirectional analysis and global processing.

Buying, Selling, Trading Siecor 340M-6

Siecor 340M-5710 Module 850/1300/1310/1550 nm MM/SM with +10 dBm meter Specifications:

Center Wavelength
20/± 20 nm 850/1300 nm
1310/1550 nm
Dynamic Range
20.5/22.5 dB
32/30 dB
Attenuation Deadzone 8/9 m
11/12 m
Reflective Deadzone (typical) 3 m (multimode) / 3.5 m (single-mode)
Pulse width
(wavelength dependent) 4 ns to 10 µs (multimode); 10 ns to 30 µs (single-mode)
Spectral Width (RMS) 10 nm
Loss Resolution 0.001 dB
Distance Resolution 0.0001 km; 0.01 meters; 0.001 kft; 1ft; 0.0001 mi
Distance Sampling 0.25, 0.5, 1, 2, 4, 8, 16 m (range dependent)
Distance Accuracy 0.0025% of distance measurement +/- distance resolution +/- index uncertainty
Laser Certification CDRH class 1 requirements (eye safe) 21 CFR

VFL Specifications:

Wavelength 635 ± 10 nm
Output Power = -2 dBm (0 dBm max)
Transmission CW or 2 Hz (blink)
Connector (fixed) FC, SC, or ST® Compatible
Laser Certification IEC 825 Class 2, FDA (21CFR), Class 2

Power Meter Specifications:

Calibrated Wavelengths 850/1300/1310/1550nm
Optical Meter Range
(factory-installed) Standard: +10 to -55 dBm
CATV: +20 to -45 dBm, with mf-460 filter
Detector Type 2 mm Ge PIN photodiode
Wavelength 800 – 1800 nm
Resolution 0.01 dBm, 0.01% Watts
Store Reference Mode Yes
Accuracy ± 4% @ +5 to -50 dBm
± 8% @ +10 to +5 dBm and @ -50 to -55 dBm
Linearity ± 0.04 dB, +5 to -55 dBm

If you’re selling your Siecor 340M-6 please fill out form on the right hand side of page.

Selling Siecor 340M-5710 – We Buy New Used 340M-5710 (‘s) Top Dollar Paid!

If you’re looking to Sell Siecor 340M-5710 Corning Siecor OTDR Plus Multitester II

Applications

LAN
Telco
CATV
Description
The Model 340 OTDR Plus™ Multitester II offers true multitesting capability that features field-installable single-mode, multimode and quad OTDR modules, visual fault locator, as well as optional built-in power meter and laser source. The standard unit provides internal solid-state memory for 125 traces and a floppy disk drive. An optional hard drive is also offered to allow mass data storage and speeds testing by eliminating the need to constantly exchange floppy disks in the standard drive. The product line offers a large variety of high-performance multimode and single-mode modules featuring a superior single-mode unit with 46 dB dynamic range. SoftView™ Emulation Software provides desktop analysis and quality documentation capability.

A large 10.4-in (26.4 cm) display is easy to read and eliminates the need to jump from screen to screen to view results. Because it is active matrix color, readability is further enhanced. The extraordinary strength, durability and weather resistance of the custom polymer housing protects your equipment investment.

Troubleshooting with the 340 is quick and easy with the SmartTest™ Function. At the touch of a button, the 340 selects the parameters and then tests the fiber. The DualTrace™ Function tests and displays both wavelengths on one graph. The multitasking operating system provides fast fiber analysis and data collection. The DualPulse feature allows measurement of the same fiber with two pulse widths to optimize resolution and distance measurements.

Repetitive testing and documentation of each fiber is reduced to the shortest possible time using the AutoIncrement™ Function. Only one button per fiber is needed to record both a trace and event table at both wavelengths. Pop-up dialog boxes guide you from fiber-to-fiber and provide warnings if a fault of above-threshold loss is found.

Features / Benefits

SmartTest™ Function provides a fast, one-button analysis of the entire fiber
AutoIncrement™ Function speeds up repetitive as-built testing in high-fiber-count projects, saving time, money and reducing error
DualTrace™ Function shows optimal traces at both wavelengths on one graph for easy analysis
Large variety of high-performance modules available – single-mode up to 46 dB offers significant distance capacity and enhances event search capabilities
Multitest capabilities offer all-in-one convenience on a field-upgradeable platform
SoftView™ Emulation Software for batch printing and editing, trace overlay and bidirectional analysis
Large display with active matrix color eases eyestrain during periods of extended use
Commercially available rechargeable batteries offer hours of autonomous operation
AC adapter as well as a 12 V DC power adapter
Multilingual operating and help screens
Quick and efficient location of fiber breaks and previous event for landmarking
Flexible Universal Connector System
Telcordia compliant, including GR-196 formatted traces
Level 3 approved

The Multitester Concept
The 340 combines single-mode, multimode and quad OTDR capabilities along with a power meter, visual fault locator and stabilized singlemode light source into a compact platform that resides in a rugged polymer housing. Virtually any field testing can be accomplished with the unit. Capabilities include incoming reel inspections, link loss measurements, fiber attenuation (dB/km), splice and connector loss, reflectance and optical return loss measurement, length measurement, visual fault location and a 2 kHz test tone for fiber identification. With the many range and test options available, the unit can be optimized for access, data center, telco or CATV applications. Specialty modules for water intrusion (1244 nm) S-band (1410 nm) and out of band (1625 nm) testing are also available. Because the platform is modular and field-installed, OTDR and VFL options not ordered initially can be added at a later date.

OTDR Functions
The 340 is two OTDRs in one – single-mode and multimode – making it ideal for LAN testing, where both fiber types are common. With up to 46 dB of single-mode range available, the 340 is a powerful tool for telco and CATV applications as well.

Power Meter
The built-in power meter options make end-toend testing easy because data can be saved to disk and analyzed/printed with the same software used for OTDR traces. For CATV applications, a range of +20 dBm is available.

Visual Fault Locator
The field-installable VFL makes fault location within the OTDR’s deadzone possible as well as provides visual continuity checks.

Single-mode Source
Units equipped with single-mode OTDR capability can also be equipped to function as a stabilized laser source for loss measurement.

2 kHz Test Tone
Fiber identifiers such as the CheckPoint™ and CheckPoint Plus can recognize this tone to locate a fiber at a splice or repair point.

Fault Locate Function
The OTDR operates as a simple fault locator. At the touch of a button, the unit quickly and accurately finds the end of the fiber.

SmartTest™ Function
Think of the SmartTest Function as the built-in expert. One key press will select the best parameters for the connected fiber, acquire the data and present both a trace and an event table on one screen. Both novice and expert will benefit from quick and complete fiber characterization. For the novice, getting good results requires only minimal equipment knowledge. For the expert, the SmartTest Function can quickly set machine parameters.

DualTrace™ Function
On one screen, the DualTrace Function characterizes a fiber at both wavelengths, optimizing the pulse width for each. Visual comparison of performance at each wavelength is greatly enhanced by combining both traces into one graph. Wavelength-dependent losses, such as bending and pinching in splice trays, tight bends in cable placement and compression due to temperature extremes, are also easier to identify in the DualTrace Function view. Such events will exhibit greater loss at the longer wavelength, both on the traces and in the event table.

DualPulse Function
A fiber is tested at a single wavelength with two pulse widths. Two traces are displayed, one for each pulsewidth. The short pulse provides optimal event resolution, while the longer pulse provides excellent distant measurements.

AutoIncrement™ Function
Documentation of new installations and repairs is performed quickly with the AutoIncrement Function. This function can create traces and event tables at both wavelengths, save them to disk and prompt the user for the next fiber when ready. If any un-acceptable losses are detected, the user is informed before proceeding. Sequential file names are automatically incremented for each fiber in the test.

Data Storage
Data is stored to either the internal solid-state memory, a standard floppy drive or an optional hard drive. More than 80,000 traces can be stored on the internal hard drive. Floppy disks may be created directly from the hard drive. Data can also be stored in other compatible file formats such as the standard Telcordia GR-196 format.

PC Emulation Software
SoftView™ Emulation Software turns a notebook or office PC into a fiber analysis workstation with powerful batch printing, reporting and editing tools. Virtually all the functions available on the OTDR are available on the PC for data stored to disk. SoftView Emulation Software provides manual operation with view trace, eight-trace compare, Telcordia GR-196 formatted trace measurement, save and recall, plus fast analysis and batch printing, fast templates, bidirectional analysis and global processing.

Buying, Selling, Trading Siecor 340M-5710

Siecor 340M-5710 Module 850/1300/1310/1550 nm MM/SM with +10 dBm meter Specifications:

Center Wavelength
20/± 20 nm 850/1300 nm
1310/1550 nm
Dynamic Range
20.5/22.5 dB
32/30 dB
Attenuation Deadzone 8/9 m
11/12 m
Reflective Deadzone (typical) 3 m (multimode) / 3.5 m (single-mode)
Pulse width
(wavelength dependent) 4 ns to 10 µs (multimode); 10 ns to 30 µs (single-mode)
Spectral Width (RMS) 10 nm
Loss Resolution 0.001 dB
Distance Resolution 0.0001 km; 0.01 meters; 0.001 kft; 1ft; 0.0001 mi
Distance Sampling 0.25, 0.5, 1, 2, 4, 8, 16 m (range dependent)
Distance Accuracy 0.0025% of distance measurement +/- distance resolution +/- index uncertainty
Laser Certification CDRH class 1 requirements (eye safe) 21 CFR

VFL Specifications:

Wavelength 635 ± 10 nm
Output Power = -2 dBm (0 dBm max)
Transmission CW or 2 Hz (blink)
Connector (fixed) FC, SC, or ST® Compatible
Laser Certification IEC 825 Class 2, FDA (21CFR), Class 2

Power Meter Specifications:

Calibrated Wavelengths 850/1300/1310/1550nm
Optical Meter Range
(factory-installed) Standard: +10 to -55 dBm
CATV: +20 to -45 dBm, with mf-460 filter
Detector Type 2 mm Ge PIN photodiode
Wavelength 800 – 1800 nm
Resolution 0.01 dBm, 0.01% Watts
Store Reference Mode Yes
Accuracy ± 4% @ +5 to -50 dBm
± 8% @ +10 to +5 dBm and @ -50 to -55 dBm
Linearity ± 0.04 dB, +5 to -55 dBm

If you’re selling your Siecor 340M-5710 please fill out form on the right hand side of page.

Selling Corning OV-Mini – We Buy New Used OV-Mini (‘s) Top Dollar Paid!

If you’re looking to Sell Corning OV-Mini SM MM Fiber OTDR MiniBK

Corning OV-Mini MiniBK
Corning Cable Systems OV-Mini Optical Time Domain Reflectometer (OTDR) provides a rugged, handheld and lightweight solution for testing and troubleshooting fiber optic networks. This handheld OTDR gives the operator the flexibility of testing single-mode and 50 and 62.5 µm multimode systems with the same unit. The OV-Mini provides complete connectivity flexibility (with USB stick compatability and USB cable download) and top user-friendliness (offering one-touch testing).


FEATURES
:

  • OptiTest function. One-touch testing for top user-friendliness
  • USB port (memory-stick compatible).  Easy data transfer
  • Large internal memory.  Up to 500 results
  • Transreflective color display.  View clear results under bright sunlight
  • Superior automated analysis.  Better, easier and faster diagnosis

Buying, Selling, Trading Corning OV-Mini

If you’re selling your Corning OV-Mini please fill out form on the right hand side of page.

Selling Siecor 340M-5611 – We Buy New Used 340M-5611 (‘s) Top Dollar Paid!

If you’re looking to Sell Siecor 340M-5611 Corning Siecor OTDR Plus Multitester II

Applications

  • LAN
  • Telco
  • CATV

Description
The Model 340 OTDR Plus™ Multitester II offers true multitesting capability that features field-installable single-mode, multimode and quad OTDR modules, visual fault locator, as well as optional built-in power meter and laser source. The standard unit provides internal solid-state memory for 125 traces and a floppy disk drive. An optional hard drive is also offered to allow mass data storage and speeds testing by eliminating the need to constantly exchange floppy disks in the standard drive. The product line offers a large variety of high-performance multimode and single-mode modules featuring a superior single-mode unit with 46 dB dynamic range. SoftView™ Emulation Software provides desktop analysis and quality documentation capability.

A large 10.4-in (26.4 cm) display is easy to read and eliminates the need to jump from screen to screen to view results. Because it is active matrix color, readability is further enhanced. The extraordinary strength, durability and weather resistance of the custom polymer housing protects your equipment investment.

Troubleshooting with the 340 is quick and easy with the SmartTest™ Function. At the touch of a button, the 340 selects the parameters and then tests the fiber. The DualTrace™ Function tests and displays both wavelengths on one graph. The multitasking operating system provides fast fiber analysis and data collection. The DualPulse feature allows measurement of the same fiber with two pulse widths to optimize resolution and distance measurements.

Repetitive testing and documentation of each fiber is reduced to the shortest possible time using the AutoIncrement™ Function. Only one button per fiber is needed to record both a trace and event table at both wavelengths. Pop-up dialog boxes guide you from fiber-to-fiber and provide warnings if a fault of above-threshold loss is found.

Buying, Selling, Trading Siecor 340M-5611

Features / Benefits

  • SmartTest™ Function provides a fast, one-button analysis of the entire fiber
  • AutoIncrement™ Function speeds up repetitive as-built testing in high-fiber-count projects, saving time, money and reducing error
  • DualTrace™ Function shows optimal traces at both wavelengths on one graph for easy analysis
  • Large variety of high-performance modules available – single-mode up to 46 dB offers significant distance capacity and enhances event search capabilities
  • Multitest capabilities offer all-in-one convenience on a field-upgradeable platform
  • SoftView™ Emulation Software for batch printing and editing, trace overlay and bidirectional analysis
  • Large display with active matrix color eases eyestrain during periods of extended use
  • Commercially available rechargeable batteries offer hours of autonomous operation
  • AC adapter as well as a 12 V DC power adapter
  • Multilingual operating and help screens
  • Quick and efficient location of fiber breaks and previous event for landmarking
  • Flexible Universal Connector System
  • Telcordia compliant, including GR-196 formatted traces
  • Level 3 approved

 

The Multitester Concept
The 340 combines single-mode, multimode and quad OTDR capabilities along with a power meter, visual fault locator and stabilized singlemode light source into a compact platform that resides in a rugged polymer housing. Virtually any field testing can be accomplished with the unit. Capabilities include incoming reel inspections, link loss measurements, fiber attenuation (dB/km), splice and connector loss, reflectance and optical return loss measurement, length measurement, visual fault location and a 2 kHz test tone for fiber identification. With the many range and test options available, the unit can be optimized for access, data center, telco or CATV applications. Specialty modules for water intrusion (1244 nm) S-band (1410 nm) and out of band (1625 nm) testing are also available. Because the platform is modular and field-installed, OTDR and VFL options not ordered initially can be added at a later date.

OTDR Functions
The 340 is two OTDRs in one – single-mode and multimode – making it ideal for LAN testing, where both fiber types are common. With up to 46 dB of single-mode range available, the 340 is a powerful tool for telco and CATV applications as well.

Power Meter
The built-in power meter options make end-toend testing easy because data can be saved to disk and analyzed/printed with the same software used for OTDR traces. For CATV applications, a range of +20 dBm is available.

Visual Fault Locator
The field-installable VFL makes fault location within the OTDR’s deadzone possible as well as provides visual continuity checks.

Single-mode Source
Units equipped with single-mode OTDR capability can also be equipped to function as a stabilized laser source for loss measurement.

2 kHz Test Tone
Fiber identifiers such as the CheckPoint™ and CheckPoint Plus can recognize this tone to locate a fiber at a splice or repair point.

Fault Locate Function
The OTDR operates as a simple fault locator. At the touch of a button, the unit quickly and accurately finds the end of the fiber.

SmartTest™ Function
Think of the SmartTest Function as the built-in expert. One key press will select the best parameters for the connected fiber, acquire the data and present both a trace and an event table on one screen. Both novice and expert will benefit from quick and complete fiber characterization. For the novice, getting good results requires only minimal equipment knowledge. For the expert, the SmartTest Function can quickly set machine parameters.

DualTrace™ Function
On one screen, the DualTrace Function characterizes a fiber at both wavelengths, optimizing the pulse width for each. Visual comparison of performance at each wavelength is greatly enhanced by combining both traces into one graph. Wavelength-dependent losses, such as bending and pinching in splice trays, tight bends in cable placement and compression due to temperature extremes, are also easier to identify in the DualTrace Function view. Such events will exhibit greater loss at the longer wavelength, both on the traces and in the event table.

DualPulse Function
A fiber is tested at a single wavelength with two pulse widths. Two traces are displayed, one for each pulsewidth. The short pulse provides optimal event resolution, while the longer pulse provides excellent distant measurements.

AutoIncrement™ Function
Documentation of new installations and repairs is performed quickly with the AutoIncrement Function. This function can create traces and event tables at both wavelengths, save them to disk and prompt the user for the next fiber when ready. If any un-acceptable losses are detected, the user is informed before proceeding. Sequential file names are automatically incremented for each fiber in the test.

Data Storage
Data is stored to either the internal solid-state memory, a standard floppy drive or an optional hard drive. More than 80,000 traces can be stored on the internal hard drive. Floppy disks may be created directly from the hard drive. Data can also be stored in other compatible file formats such as the standard Telcordia GR-196 format.

PC Emulation Software
SoftView™ Emulation Software turns a notebook or office PC into a fiber analysis workstation with powerful batch printing, reporting and editing tools. Virtually all the functions available on the OTDR are available on the PC for data stored to disk. SoftView Emulation Software provides manual operation with view trace, eight-trace compare, Telcordia GR-196 formatted trace measurement, save and recall, plus fast analysis and batch printing, fast templates, bidirectional analysis and global processing.

If you’re selling your Siecor 340M-5611 please fill out form on the right hand side of page.

Selling Siecor 340M-5620 – We Buy New Used 340M-5620 (‘s) Top Dollar Paid!

If you’re looking to Sell Siecor 340M-5620 SM MM Fiber OTDR Module

340M-5620 Specifications:

Center Wavelength
20/± 20 nm 850/1300 nm
1310/1550 nm
Dynamic Range
23/25 dB
22/21 dB
Attenuation Deadzone 8/9 m
11/12 m
Reflective Deadzone (typical) 3 m (multimode) / 3.5 m (single-mode)
Pulse width
(wavelength dependent) 4 ns to 10 µs (multimode); 10 ns to 30 µs (single-mode)
Spectral Width (RMS) 10 nm
Loss Resolution 0.001 dB
Distance Resolution 0.0001 km; 0.01 meters; 0.001 kft; 1ft; 0.0001 mi
Distance Sampling 0.25, 0.5, 1, 2, 4, 8, 16 m (range dependent)
Distance Accuracy 0.0025% of distance measurement +/- distance resolution +/- index uncertainty
Laser Certification CDRH class 1 requirements (eye safe) 21 CFR

Buying, Selling, Trading Siecor 340M-5620

Power Meter Specifications:

Calibrated Wavelengths 850/1300/1310/1550nm
Optical Meter Range
(factory-installed) Standard: +10 to -55 dBm
CATV: +20 to -45 dBm, with mf-460 filter
Detector Type 2 mm Ge PIN photodiode
Wavelength 800 – 1800 nm
Resolution 0.01 dBm, 0.01% Watts
Store Reference Mode Yes
Accuracy ± 4% @ +5 to -50 dBm
± 8% @ +10 to +5 dBm and @ -50 to -55 dBm
Linearity ± 0.04 dB, +5 to -55 dBm

If you’re selling your Siecor 340M-5620 please fill out form on the right hand side of page.

Selling Corning 400 – We Buy New Used 400 (‘s) Top Dollar Paid!

If you’re looking to Sell Corning 400 SM MM Fiber OTDR VFL

Applications

Testing and troubleshooting of LAN, telco, CATV and FTTx networks

Corning Cable Systems’ OptiVisor 400 Optical Time Domain Reflectometer (OTDR) provides testing flexibility by offering a rugged platform with field-interchangeable multimode and single-mode modules. All OTDR modules can be used as CW light source and are available with an optional visual fault locator (VFL) installed. An optional power meter is available on the OptiVisor 400 OTDR mainframe. The standard unit provides internal memory for storage of up to 700 traces using Microsoft® Windows® CE technology, eliminating the need for a hard drive. If extra storage capacity is needed, there is a 1.44 MB floppy drive on the mainframe along with a PCMCIA port.

The OptiVisor 400 OTDR product line offers a wide variety of multimode and single-mode modules including a tri-wavelength single-mode module perfect for FTTx testing. Modules can be easily switched out in the field, without the use of tools, in just a matter of seconds.

The OTDR features a 7.7-inch high-quality color LCD touch screen that is resistant to most common chemicals used in the field. The screen is large enough to view both the trace and the event table, thereby eliminating the need to toggle back and forth between the two.

With three testing modes, the OptiVisor 400 OTDR offers something for every installer. Auto Mode allows the user to select the parameters automatically, making it perfect for basic OTDR applications or the occasional user. Advanced Mode offers more setup and measurement capabilities for the experienced OTDR user. Template Trace Mode allows the user to create a template for comparison with other traces, ideal for quick testing of multiple fibers.

Features / Benefits

Rugged, splash-proof mainframe
Three operating modes: Auto, Advanced, Template Trace
7.7-in color LCD touchscreen
FTTx ready
CW light source standard on all OTDR modules
OTSView software for report generation
Modules available with shortest event dead zone in the industry: 1 meter with 5 ns pulse width
Fast testing with full averaging in as little as 45 seconds; four times faster than industry standard
AC and battery operation
Sample points of up to 128,000 resulting in better trace resolution

Buying, Selling, Trading Corning 400

Specifications

400 OTDR Main Frame

Processor Intel StrongARM, 206 MHz
Interfaces Serial RS-232C; Parallel Printer
External Keyboard PS/2; PCMCIA Type II
Internal Memory 32 MB total (700 traces typ.), standard
Additional Storage (optional) PCMCIA flash cards, up to 6000 traces
Floppy Drive 3.5 inch floppy drive, 1.44 MB
Display Color LCD touchscreen, 19.6 cm (7.7 in), 640 x 480, 256 colors
Touchscreen Resistive, 8 wires; positional accuracy better than 2%, full scale, worst-case error .} 0.5 cm (0.18 in); resistant to most common chemicals
External Power Supply AC input: 100 to 240 V, 50 Hz to 60 Hz
Battery Nickel metal-hydride (NiMH), rechargeable, smart
Battery Operating Time 8 h – NiMH battery
RechargeTime 2.5 h (off), 8 h (on)
Size (H x W x D) 21.6 x 33.6 x 8.9 cm (8.5 x 13.25 x 3.5 in)
Weight 3.7 kg (8.1 lb)
Operating Temperature -5o to 50oC (23o to 122oF)
Storage Temperature -40o to 60oC (-40o to 140oF), Shipping
-20o to 50oC (-4o to 122oF), Long Term
Relative Humidity 0% to 95% max., non-condensing
400-MDSD-58-VFL SM MM Module
Wavelength (nm) 850 ± 10/1300 ± 10
1310± 10/1550± 10
Dynamic Range at 100 ns/1µs (dB) 850/1300nm : 23/27dB
1310/1550nm : 35/34dB
Event Dead Zone (m) 1/1
Attenuation Dead Zone (m) 3/4

If you’re selling your Corning 400 please fill out form on the right hand side of page.

Selling Siecor 340M-5721 – We Buy New Used 340M-5721 (‘s) Top Dollar Paid!

If you’re looking to Sell Siecor 340M-5721 Corning Siecor OTDR Plus Multitester II

Applications

  • LAN
  • Telco
  • CATV

Description
The Model 340 OTDR Plus™ Multitester II offers true multitesting capability that features field-installable single-mode, multimode and quad OTDR modules, visual fault locator, as well as optional built-in power meter and laser source. The standard unit provides internal solid-state memory for 125 traces and a floppy disk drive. An optional hard drive is also offered to allow mass data storage and speeds testing by eliminating the need to constantly exchange floppy disks in the standard drive. The product line offers a large variety of high-performance multimode and single-mode modules featuring a superior single-mode unit with 46 dB dynamic range. SoftView™ Emulation Software provides desktop analysis and quality documentation capability.

A large 10.4-in (26.4 cm) display is easy to read and eliminates the need to jump from screen to screen to view results. Because it is active matrix color, readability is further enhanced. The extraordinary strength, durability and weather resistance of the custom polymer housing protects your equipment investment.

Troubleshooting with the 340 is quick and easy with the SmartTest™ Function. At the touch of a button, the 340 selects the parameters and then tests the fiber. The DualTrace™ Function tests and displays both wavelengths on one graph. The multitasking operating system provides fast fiber analysis and data collection. The DualPulse feature allows measurement of the same fiber with two pulse widths to optimize resolution and distance measurements.

Repetitive testing and documentation of each fiber is reduced to the shortest possible time using the AutoIncrement™ Function. Only one button per fiber is needed to record both a trace and event table at both wavelengths. Pop-up dialog boxes guide you from fiber-to-fiber and provide warnings if a fault of above-threshold loss is found.

Features / Benefits

  • SmartTest™ Function provides a fast, one-button analysis of the entire fiber
  • AutoIncrement™ Function speeds up repetitive as-built testing in high-fiber-count projects, saving time, money and reducing error
  • DualTrace™ Function shows optimal traces at both wavelengths on one graph for easy analysis
  • Large variety of high-performance modules available – single-mode up to 46 dB offers significant distance capacity and enhances event search capabilities
  • Multitest capabilities offer all-in-one convenience on a field-upgradeable platform
  • SoftView™ Emulation Software for batch printing and editing, trace overlay and bidirectional analysis
  • Large display with active matrix color eases eyestrain during periods of extended use
  • Commercially available rechargeable batteries offer hours of autonomous operation
  • AC adapter as well as a 12 V DC power adapter
  • Multilingual operating and help screens
  • Quick and efficient location of fiber breaks and previous event for landmarking
  • Flexible Universal Connector System
  • Telcordia compliant, including GR-196 formatted traces
  • Level 3 approved

The Multitester Concept
The 340 combines single-mode, multimode and quad OTDR capabilities along with a power meter, visual fault locator and stabilized singlemode light source into a compact platform that resides in a rugged polymer housing. Virtually any field testing can be accomplished with the unit. Capabilities include incoming reel inspections, link loss measurements, fiber attenuation (dB/km), splice and connector loss, reflectance and optical return loss measurement, length measurement, visual fault location and a 2 kHz test tone for fiber identification. With the many range and test options available, the unit can be optimized for access, data center, telco or CATV applications. Specialty modules for water intrusion (1244 nm) S-band (1410 nm) and out of band (1625 nm) testing are also available. Because the platform is modular and field-installed, OTDR and VFL options not ordered initially can be added at a later date.

OTDR Functions
The 340 is two OTDRs in one – single-mode and multimode – making it ideal for LAN testing, where both fiber types are common. With up to 46 dB of single-mode range available, the 340 is a powerful tool for telco and CATV applications as well.

Power Meter
The built-in power meter options make end-toend testing easy because data can be saved to disk and analyzed/printed with the same software used for OTDR traces. For CATV applications, a range of +20 dBm is available.

Visual Fault Locator
The field-installable VFL makes fault location within the OTDR’s deadzone possible as well as provides visual continuity checks.

Single-mode Source
Units equipped with single-mode OTDR capability can also be equipped to function as a stabilized laser source for loss measurement.

2 kHz Test Tone
Fiber identifiers such as the CheckPoint™ and CheckPoint Plus can recognize this tone to locate a fiber at a splice or repair point.

Fault Locate Function
The OTDR operates as a simple fault locator. At the touch of a button, the unit quickly and accurately finds the end of the fiber.

SmartTest™ Function
Think of the SmartTest Function as the built-in expert. One key press will select the best parameters for the connected fiber, acquire the data and present both a trace and an event table on one screen. Both novice and expert will benefit from quick and complete fiber characterization. For the novice, getting good results requires only minimal equipment knowledge. For the expert, the SmartTest Function can quickly set machine parameters.

DualTrace™ Function
On one screen, the DualTrace Function characterizes a fiber at both wavelengths, optimizing the pulse width for each. Visual comparison of performance at each wavelength is greatly enhanced by combining both traces into one graph. Wavelength-dependent losses, such as bending and pinching in splice trays, tight bends in cable placement and compression due to temperature extremes, are also easier to identify in the DualTrace Function view. Such events will exhibit greater loss at the longer wavelength, both on the traces and in the event table.

DualPulse Function
A fiber is tested at a single wavelength with two pulse widths. Two traces are displayed, one for each pulsewidth. The short pulse provides optimal event resolution, while the longer pulse provides excellent distant measurements.

AutoIncrement™ Function
Documentation of new installations and repairs is performed quickly with the AutoIncrement Function. This function can create traces and event tables at both wavelengths, save them to disk and prompt the user for the next fiber when ready. If any un-acceptable losses are detected, the user is informed before proceeding. Sequential file names are automatically incremented for each fiber in the test.

Data Storage
Data is stored to either the internal solid-state memory, a standard floppy drive or an optional hard drive. More than 80,000 traces can be stored on the internal hard drive. Floppy disks may be created directly from the hard drive. Data can also be stored in other compatible file formats such as the standard Telcordia GR-196 format.

Buying, Selling, Trading Siecor 340M-5721

PC Emulation Software
SoftView™ Emulation Software turns a notebook or office PC into a fiber analysis workstation with powerful batch printing, reporting and editing tools. Virtually all the functions available on the OTDR are available on the PC for data stored to disk. SoftView Emulation Software provides manual operation with view trace, eight-trace compare, Telcordia GR-196 formatted trace measurement, save and recall, plus fast analysis and batch printing, fast templates, bidirectional analysis and global processing.

If you’re selling your Siecor 340M-5721 please fill out form on the right hand side of page.